{"id":2781,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/hsu-01-high-speed-unwinding-force-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"hsu-01-high-speed-unwinding-force-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/vi\/products\/hsu-01-high-speed-unwinding-force-tester.html","title":{"rendered":"HSU-01 High Speed Unwinding Force Tester"},"content":{"rendered":"<p>1. L\u1eddi m\u1edf \u0111\u1ea7u<br \/>\nHSU-01 high-speed unwinding force tester, also known as a tape unwind tester, is a machine designed to measure the force required to unwind adhesive tapes from their rolls at a rapid, controlled speed.<\/p>\n<p>2. Principle<br \/>\nA specimen roll that is mounted upon a free-turning roller assembly. A loadcell meaning the unwinding force is attached to the roller. A driven roll of the machine operates at a constant rate of up to 60\u00b13 m\/min, to unwinding the roll. The unwinding force is measured in the process.<\/p>\n<p>3. Benefits<br \/>\nHigh speed unwinding\u00a0<a class=\"aahaf6o\" title=\"force test\" href=\"https:\/\/www.materialstests.com\/vi\/productstags\/ampoule-break-force-tester.html\/\">force test<\/a>\u00a0is one of the many procedures for testing pressure-sensitive adhesive-coated tapes.<br \/>\n1. Unwind adhesion determines the force needed in unrolling a roll of tape. Unwinding at high speed will give indication of the unwind performance in use.<br \/>\n2. Unwind force of pressure-sensitive adhesive tape is the force required to remove the tape from the roll when measured in accordance with this test method.<br \/>\nThe unwind force at the specified rate gives information on the combined effects of the interlayer adhesion in the roll and of the physical condition of the backing and adhesive mass. This unwind force is useful as a measure of the effects of natural, shelf or accelerated aging, and the unwind force determined at the fast rate of removal is useful as a measure of the ease of unwinding in mechanized or hand dispensers. A tape width of 25 mm (1 in.) is considered optimum for this test method.<\/p>\n<p>4.\u00a0Technical Features<br \/>\nPLC controlled<br \/>\nHMI touch screen operated.<br \/>\nServo motor is used for a stable movement in the test.<br \/>\nRoll size can be customized.<\/p>\n<p>5. Specifications<\/p>\n<div class=\"table\">\n<table>\n<colgroup>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr>\n<td>Specimen Size<\/td>\n<td align=\"left\">Reel Diameter 75mm, Width 75mm. Max Outer Dia 300mm (customization available)<\/td>\n<\/tr>\n<tr>\n<td>Loadcell<\/td>\n<td align=\"left\">10kg, 20kg and 50kg are optional<\/td>\n<\/tr>\n<tr>\n<td>Force Resolution<\/td>\n<td align=\"left\">0.01N<\/td>\n<\/tr>\n<tr>\n<td>Motor<\/td>\n<td align=\"left\">Servo Type<\/td>\n<\/tr>\n<tr>\n<td>Ki\u1ec3m so\u00e1t<\/td>\n<td align=\"left\">PLC v\u00e0 m\u00e0n h\u00ecnh c\u1ea3m \u1ee9ng HMI<\/td>\n<\/tr>\n<tr>\n<td>C\u00f4ng su\u1ea5t<\/td>\n<td align=\"left\">AC 110~220V 50Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>6. Standards: PSTC-13, ASTM D1000, EN 12026, AFERA 4008<\/p>\n<p>7. FAQs<br \/>\nWhat is \u201cUnwind adhesion\u201d?<br \/>\nUnwind adhesion is the force required to remove the tape from the roll under prescribed conditions.<\/p>\n<p class=\"aahaf6o\">N\u1ebfu qu\u00fd kh\u00e1ch mu\u1ed1n bi\u1ebft th\u00eam th\u00f4ng tin v\u1ec1 s\u1ea3n ph\u1ea9m n\u00e0y, xin vui l\u00f2ng li\u00ean h\u1ec7 v\u1edbi ch\u00fang t\u00f4i. D\u01b0\u1edbi \u0111\u00e2y l\u00e0 m\u1ed9t s\u1ed1 s\u1ea3n ph\u1ea9m ph\u1ed5 bi\u1ebfn kh\u00e1c m\u00e0 ch\u00fang t\u00f4i g\u1ee3i \u00fd cho qu\u00fd kh\u00e1ch:\u00a0<a class=\"aahaf6o\" title=\"c\u00e1c l\u1ef1c t\u00e1c d\u1ee5ng l\u00ean p\u00edt-t\u00f4ng c\u1ee7a \u1ed1ng ti\u00eam\" href=\"https:\/\/www.materialstests.com\/vi\/productstags\/forces-on-plunger-of-syringe.html\/\">c\u00e1c l\u1ef1c t\u00e1c d\u1ee5ng l\u00ean p\u00edt-t\u00f4ng c\u1ee7a \u1ed1ng ti\u00eam<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>1. Introduction HSU-01 high-speed unwinding force tester, also known as a tape unwind tester, is a machine designed to measure the force required to unwind adhesive tapes from their rolls at a rapid, controlled speed. 2. Principle A specimen roll that is mounted upon a free-turning roller assembly. A loadcell meaning the unwinding force is [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1303],"productstags":[1304,1305,1306,1307,1308,1309],"standard-category":[],"class_list":["post-2781","products","type-products","status-publish","hentry","products-categories-adhesiveness-tester","productstags-ampoule-break-force-test","productstags-ampoule-break-force-tester","productstags-force-to-push-a-syringe-plunger","productstags-syringe-plunger-force","productstags-syringe-plunger-force-calculation","productstags-syringe-plunger-stopper-force-calculation"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/products\/2781","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/products\/2781\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/media?parent=2781"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/products-categories?post=2781"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/productstags?post=2781"},{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.materialstests.com\/vi\/wp-json\/wp\/v2\/standard-category?post=2781"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}