{"id":2774,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/ts-01-syringe-tube-stiffness-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"ts-01-syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/tr\/products\/ts-01-syringe-tube-stiffness-tester.html","title":{"rendered":"TS-01 \u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131"},"content":{"rendered":"<h2><strong>Genel Bak\u0131\u015f<\/strong><\/h2>\n<p>Bu\u00a0<strong><a href=\"https:\/\/www.materialstests.com\/tr\/medical-device-tester.html\/\">\u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik \u00d6l\u00e7er<\/a>\u00a0(TS-01)<\/strong>\u00a0t\u0131bbi hortumlar\u0131n, \u00f6zellikle de enjeksiyon i\u011fneleri ve \u015f\u0131r\u0131ngalar\u0131n sertli\u011fini \u00f6l\u00e7mek \u00fczere tasarlanm\u0131\u015f y\u00fcksek hassasiyetli bir test cihaz\u0131d\u0131r.\u00a0<strong>sertlik<\/strong>\u00a0t\u0131bbi hortumlar\u0131n g\u00fcvenli\u011fini, esnekli\u011fini ve genel performans\u0131n\u0131 do\u011frudan etkiler; do\u011fru\u00a0<strong>sertlik testi<\/strong>\u00a0Hortumun mekanik mukavemet ile esneklik aras\u0131nda do\u011fru dengeyi korumas\u0131n\u0131 sa\u011flamak hayati \u00f6nem ta\u015f\u0131r. A\u015f\u0131r\u0131 sert hortumlar k\u0131r\u0131lma veya gevrek k\u0131r\u0131lma riskini art\u0131rabilirken, a\u015f\u0131r\u0131 yumu\u015fak hortumlar b\u00fck\u00fclmeye, hasara ve potansiyel olarak g\u00fcvenli olmayan t\u0131bbi i\u015flemlere yol a\u00e7abilir.<\/p>\n<p>Bu\u00a0<strong>T\u0131bbi \u0130\u011fne Sertlik \u00d6l\u00e7er<\/strong>\u00a0Bu sistem, t\u00fcp\u00fcn merkezine belirli bir kuvvet uygulayarak ve sapmas\u0131n\u0131 \u00f6l\u00e7erek ger\u00e7ek d\u00fcnya ko\u015fullar\u0131n\u0131 sim\u00fcle edecek \u015fekilde tasarlanm\u0131\u015ft\u0131r. Bu sayede, t\u00fcp\u00fcn enjeksiyonlar, inf\u00fczyonlar ve di\u011fer kritik prosed\u00fcrler gibi t\u0131bbi uygulamalarda g\u00fcvenli bir \u015fekilde \u00e7al\u0131\u015fabilmesi i\u00e7in gerekli sertli\u011fe sahip oldu\u011fu garanti alt\u0131na al\u0131n\u0131r.<\/p>\n<hr \/>\n<h2><strong>Uygulamalar<\/strong><\/h2>\n<p>TS-01 \u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131, \u00f6zellikle\u00a0<strong>t\u0131p, ila\u00e7 ve ambalaj end\u00fcstrileri<\/strong>\u00a0\u00fcr\u00fcn g\u00fcvenli\u011fi a\u00e7\u0131s\u0131ndan boru \u00f6zelliklerinin hassas bir \u015fekilde kontrol edilmesinin hayati \u00f6nem ta\u015f\u0131d\u0131\u011f\u0131 durumlar. Ba\u015fl\u0131ca uygulama alanlar\u0131 \u015funlard\u0131r:<\/p>\n<ul>\n<li><strong>\u015e\u0131r\u0131nga \u00dcretimi<\/strong>: \u015e\u0131r\u0131ngalar\u0131n, enjeksiyon i\u011fnelerinin ve kateterlerin, yerle\u015ftirme ve kullan\u0131m s\u0131ras\u0131nda riski en aza indirmek i\u00e7in gerekli sertlik seviyesine sahip olmas\u0131n\u0131 sa\u011flamak.<\/li>\n<li><strong>T\u0131bbi Cihaz Ar-Ge<\/strong>: T\u0131bbi hortumlarda kullan\u0131lan yeni tasar\u0131m ve malzemelerin, a\u015fa\u011f\u0131dakiler gibi uluslararas\u0131 g\u00fcvenlik standartlar\u0131na uygunlu\u011funun test edilmesi,\u00a0<strong>ISO 9626<\/strong>.<\/li>\n<li><strong>Kalite Kontrol<\/strong>: Esnek t\u00fcpler ve enjeksiyon b\u00f6lgeleri gibi t\u0131bbi ambalaj malzemelerinin, yasal gereklilikleri kar\u015f\u0131lad\u0131klar\u0131ndan ve klinik kullan\u0131m s\u0131ras\u0131nda ama\u00e7land\u0131\u011f\u0131 gibi i\u015flev g\u00f6rd\u00fcklerinden emin olmak i\u00e7in yap\u0131lan rutin testler.<\/li>\n<li><strong>T\u0131bbi Ambalajlar<\/strong>: T\u0131bbi ambalajlarda kullan\u0131lan t\u00fcplerin ne \u00e7ok sert (bu durum k\u0131r\u0131lganl\u0131\u011fa yol a\u00e7abilir) ne de \u00e7ok yumu\u015fak (bu durum kullan\u0131m s\u0131ras\u0131nda esneklik sorunlar\u0131na neden olabilir) olmad\u0131\u011f\u0131n\u0131n kontrol edilmesi.<\/li>\n<li><strong>\u0130la\u00e7 End\u00fcstrisi<\/strong>: \u015e\u0131r\u0131ngalarda ve inf\u00fczyon setlerinde kullan\u0131lan hortumlar\u0131 test ederek ila\u00e7 verme sisteminin g\u00fcvenli ve g\u00fcvenilir olmas\u0131n\u0131 sa\u011flamak.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Gereklilik<\/strong><\/h2>\n<p>T\u0131p sekt\u00f6r\u00fcnde,\u00a0<strong>boru sertli\u011fi<\/strong>\u00a0sadece bir kalite \u00f6zelli\u011fi de\u011fildir\u2014bu bir\u00a0<strong>kritik g\u00fcvenlik fakt\u00f6r\u00fc<\/strong>. Bir \u015f\u0131r\u0131ngan\u0131n veya enjeksiyon i\u011fnesinin sertli\u011fi, genel performans\u0131n\u0131 etkiler ve\u00a0<strong>uygun olmayan sertlik<\/strong>\u00a0t\u0131bbi i\u015flemler s\u0131ras\u0131nda yerle\u015ftirme zorlu\u011fu, k\u0131r\u0131lma veya ar\u0131za gibi \u00e7e\u015fitli operasyonel sorunlara yol a\u00e7abilir. A\u015f\u0131r\u0131 sert t\u00fcp, gerilime maruz kald\u0131\u011f\u0131nda k\u0131r\u0131lganla\u015fabilir ve bozulabilir; bu da i\u015flem s\u0131ras\u0131nda ciddi bir ar\u0131zaya neden olabilir.<\/p>\n<p>Buna kar\u015f\u0131l\u0131k, \u00e7ok esnek veya yumu\u015fak hortumlar b\u00fck\u00fclmeye, k\u0131vr\u0131lmaya veya deforme olmaya yol a\u00e7abilir; bu da t\u0131bbi i\u015flemlerde hatalara neden olabilir, hatta sterilli\u011fi tehlikeye atabilir. \u015e\u0131r\u0131nga Hortumu Sertlik Test Cihaz\u0131, bu konuda vazge\u00e7ilmez bir ara\u00e7 sunar\u00a0<strong>\u00f6l\u00e7mek ve do\u011frulamak<\/strong>\u00a0bu cihazlarda kullan\u0131lan hortumlar\u0131n g\u00fcvenlik, esneklik ve dayan\u0131kl\u0131l\u0131k a\u00e7\u0131s\u0131ndan en uygun \u015fekilde tasarlanm\u0131\u015f olmas\u0131.<\/p>\n<hr \/>\n<h2><strong>\u00c7al\u0131\u015fma Prensibi<\/strong><\/h2>\n<p>TS-01\u00a0<strong>\u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik \u00d6l\u00e7er<\/strong>\u00a0basit ama son derece etkili bir prensipte \u00e7al\u0131\u015f\u0131r. Test s\u0131ras\u0131nda, her iki ucundan desteklenen borunun ortas\u0131na belirli bir kuvvet (maksimum 60 N) uygulan\u0131r. Test cihaz\u0131,\u00a0<strong>sapma<\/strong>\u00a0bu uygulanan kuvvete tepki olarak borunun.<\/p>\n<h4>Temel \u00d6zellikler:<\/h4>\n<ul>\n<li><strong>Kuvvet Uygulamas\u0131<\/strong>: 60\u00b0 a\u00e7\u0131yla e\u011fimli ve 1 mm silindirik yar\u0131\u00e7apl\u0131, keskin u\u00e7lu kama \u015feklindeki bir piston, boruya kontroll\u00fc bir a\u015fa\u011f\u0131 do\u011fru kuvvet uygular.<\/li>\n<li><strong>Sapma \u00d6l\u00e7\u00fcm\u00fc<\/strong>: Test cihaz\u0131 \u015funu \u00f6l\u00e7er:\u00a0<strong>sapma<\/strong>\u00a0borunun \u00e7ap\u0131 \u00b10,01 mm hassasiyetle \u00f6l\u00e7\u00fcl\u00fcr; bu, malzemenin sertli\u011fini g\u00f6sterir.<\/li>\n<li><strong>Kuvvet Aral\u0131\u011f\u0131<\/strong>: Cihaz, 1 N ile 60 N aras\u0131nda de\u011fi\u015fen kuvvetlerle hortumlar\u0131 test edebiliyor ve\u00a0<strong>geni\u015f \u00fcr\u00fcn yelpazesi<\/strong>\u00a0\u00f6l\u00e7\u00fcmlerin.<\/li>\n<\/ul>\n<p>Bu testin sonucu, borunun sertli\u011fi ile do\u011frudan ili\u015fkilidir ve \u00fcreticilerin \u00fcr\u00fcn\u00fcn kabul edilebilir aral\u0131kta olmas\u0131n\u0131 sa\u011flamas\u0131na yard\u0131mc\u0131 olur\u00a0<strong>g\u00fcvenlik ve i\u015flevsellik<\/strong>\u00a0t\u0131bbi ortamlarda.<\/p>\n<hr \/>\n<h2><strong>Teknik \u00d6zellikler<\/strong><\/h2>\n<p>TS-01 \u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131, \u00e7e\u015fitli\u00a0<strong>y\u00fcksek hassasiyetli \u00f6zellikler<\/strong>\u00a0Bu \u00f6zellikleri, onu t\u0131bbi cihaz testleri i\u00e7in vazge\u00e7ilmez bir ara\u00e7 haline getiriyor. \u0130\u015fte temel teknik \u00f6zellikler:<\/p>\n<ul>\n<li><strong>Sabit Kuvvet<\/strong>: 60 N (veya ayarlanabilir)<\/li>\n<li><strong>Test H\u0131z\u0131<\/strong>: 1 ile 500 mm\/dk aras\u0131nda ayarlanabilir<\/li>\n<li><strong>Do\u011fruluk<\/strong>: Sapma \u00f6l\u00e7\u00fcm\u00fcnde \u00b10,01 mm<\/li>\n<li><strong>G\u00fc\u00e7 Kayna\u011f\u0131<\/strong>: 110 V \u2013 220 V AC<\/li>\n<li><strong>Kontrol Sistemi<\/strong>: PLC ile kontrol edilen\u00a0<strong>7 in\u00e7 HMI dokunmatik ekran<\/strong>\u00a0kullan\u0131m kolayl\u0131\u011f\u0131 i\u00e7in<\/li>\n<li><strong>Test Aparat\u0131<\/strong>: A\u015fa\u011f\u0131 do\u011fru kuvvet testleri i\u00e7in \u00e7e\u015fitli test cihazlar\u0131 mevcuttur<\/li>\n<li><strong>A\u015f\u0131r\u0131 Y\u00fck Korumas\u0131<\/strong>: Cihaz\u0131n hasar g\u00f6rmesini \u00f6nlemek i\u00e7in dahili a\u015f\u0131r\u0131 y\u00fck korumas\u0131<\/li>\n<li><strong>Mikro Yaz\u0131c\u0131<\/strong>: Test sonu\u00e7lar\u0131n\u0131n an\u0131nda yazd\u0131r\u0131lmas\u0131 i\u00e7in<\/li>\n<\/ul>\n<p>Bunlar\u00a0<strong>y\u00fcksek hassasiyetli \u00f6zellikler<\/strong>\u00a0\u015f\u0131r\u0131nga hortumunun sertli\u011finin do\u011fru ve g\u00fcvenilir bir \u015fekilde \u00f6l\u00e7\u00fclmesini sa\u011flayarak, \u00fcreticilerin ve d\u00fczenleyici kurumlar\u0131n g\u00fcvenebilece\u011fi sonu\u00e7lar sunar.<\/p>\n<hr \/>\n<h2><strong>Avantajlar<\/strong><\/h2>\n<p>TS-01 \u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131, geleneksel sertlik test y\u00f6ntemlerine k\u0131yasla bir\u00e7ok avantaj sunar:<\/p>\n<ul>\n<li><strong>Y\u00fcksek Hassasiyet<\/strong>:\u00a0<strong>\u00b10,01 mm<\/strong>\u00a0Sapma \u00f6l\u00e7\u00fcm\u00fcndeki do\u011fruluk, kritik uygulamalar i\u00e7in son derece g\u00fcvenilir sonu\u00e7lar sa\u011flar.<\/li>\n<li><strong>Geni\u015f Uygulama Alan\u0131<\/strong>: 60 N'ye kadar ayarlanabilir kuvvet ve de\u011fi\u015fken test h\u0131zlar\u0131 sayesinde TS-01, \u00e7e\u015fitli boru tiplerine ve test gereksinimlerine uyum sa\u011flayabilir.<\/li>\n<li><strong>Kullan\u0131m Kolayl\u0131\u011f\u0131<\/strong>:\u00a0<strong>PLC kontrol sistemi<\/strong>\u00a0ve\u00a0<strong>dokunmatik ekran kullan\u0131m\u0131<\/strong>\u00a0test s\u00fcrecini basitle\u015ftirerek, kapsaml\u0131 teknik bilgi birikimi olmayanlar i\u00e7in bile kullan\u0131m\u0131 kolay hale getirir.<\/li>\n<li><strong>Dayan\u0131kl\u0131l\u0131k<\/strong>: A\u015f\u0131r\u0131 y\u00fck korumas\u0131 ve her testten sonra otomatik geri d\u00f6n\u00fc\u015f \u00f6zelli\u011fi sayesinde TS-01, y\u00fcksek hacimli test ortamlar\u0131nda bile uzun \u00f6m\u00fcrl\u00fcl\u00fck ve g\u00fcvenilirlik sa\u011flar.<\/li>\n<li><strong>Standartlara Uygunluk<\/strong>: Test cihaz\u0131, a\u015fa\u011f\u0131daki standartlara uygun olacak \u015fekilde tasarlanm\u0131\u015ft\u0131r:\u00a0<strong>ISO 9626<\/strong>\u00a0ve\u00a0<strong>GB\/T 18457<\/strong>\u00a0standartlar\u0131, t\u00fcm \u00f6l\u00e7\u00fcmlerin uluslararas\u0131 g\u00fcvenlik ve performans kurallar\u0131na uygun olmas\u0131n\u0131 sa\u011flar.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Konfig\u00fcrasyonlar ve Aksesuarlar<\/strong><\/h2>\n<p>Bu\u00a0<strong>TS-01 \u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131<\/strong>\u00a0\u00c7e\u015fitli test ihtiya\u00e7lar\u0131n\u0131 kar\u015f\u0131lamak \u00fczere \u00e7e\u015fitli standart konfig\u00fcrasyonlar ve iste\u011fe ba\u011fl\u0131 aksesuarlarla birlikte sunulur:<\/p>\n<ul>\n<li><strong>Ana Makine<\/strong>: Y\u00fck h\u00fccresine ba\u011fl\u0131 hareketli bir \u00e7apraz kafa ve test pistonundan olu\u015fur.<\/li>\n<li><strong>Test Pistonu<\/strong>: Ucunda keskin olmayan bir kama bulunan hassas piston; hortuma belirtilen kuvveti uygulamak \u00fczere tasarlanm\u0131\u015ft\u0131r.<\/li>\n<li><strong>Test Tenceresi<\/strong>: Test s\u0131ras\u0131nda hortumu sa\u011flam bir \u015fekilde sabit tutan bir tava.<\/li>\n<li><strong>G\u00fc\u00e7 Kablosu ve Sigorta<\/strong>: \u00c7al\u0131\u015fma ve g\u00fcvenlik a\u00e7\u0131s\u0131ndan zorunludur.<\/li>\n<\/ul>\n<p>A\u015fa\u011f\u0131daki gibi ek aksesuarlar:\u00a0<strong>\u00f6zel tasar\u0131m armat\u00fcrler<\/strong>\u00a0\u00c7e\u015fitli test konfig\u00fcrasyonlar\u0131 i\u00e7in, test edilecek hortuma ba\u011fl\u0131 olarak eklenebilir.<\/p>\n<hr \/>\n<h2><strong>Standartlar<\/strong><\/h2>\n<p>Bu\u00a0<strong>TS-01 \u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131<\/strong>\u00a0\u015fu ihtiya\u00e7lar\u0131 kar\u015f\u0131lamak \u00fczere tasarlanm\u0131\u015ft\u0131r\u00a0<strong>uluslararas\u0131 standartlar<\/strong>\u00a0t\u0131bbi cihaz testleri i\u00e7in, \u015funlar dahil:<\/p>\n<ul>\n<li><strong>ISO 9626<\/strong>: \u0130\u011fne \u00fcretiminde kullan\u0131lan paslanmaz \u00e7elik borular\u0131n gerekli mekanik \u00f6zelliklerini tan\u0131mlar. Bu standart, \u00e7elik borular\u0131n nihai \u00fcr\u00fcn\u00fcn gerekliliklerini kar\u015f\u0131lad\u0131\u011f\u0131ndan emin olmak i\u00e7in mukavemet ve dayan\u0131kl\u0131l\u0131klar\u0131n\u0131 de\u011ferlendirme y\u00f6ntemlerini i\u00e7erir. Gerekli kuvvet, i\u011fnenin amac\u0131n\u0131 belirleyen iki fakt\u00f6r olan i\u011fne kal\u0131nl\u0131\u011f\u0131 ve duvar kal\u0131nl\u0131\u011f\u0131na ba\u011fl\u0131d\u0131r. Test, malzemenin sertli\u011fini belirlemek i\u00e7in \u00fc\u00e7 noktal\u0131 bir b\u00fckme d\u00fczene\u011fi kullan\u0131larak ger\u00e7ekle\u015ftirilir. Ayr\u0131ca, borunun k\u0131r\u0131lmaya kar\u015f\u0131 direncini de\u011ferlendirmek i\u00e7in bir konsol b\u00fckme testi yap\u0131l\u0131r. Bu test, i\u011fnenin klinik ortamda kar\u015f\u0131la\u015f\u0131labilecek kesme kuvvetlerine dayanabilmesini sa\u011flamak i\u00e7in \u00e7ok \u00f6nemlidir.<\/li>\n<li><strong>GB\/T 18457<\/strong>: \u015e\u0131r\u0131ngalar ve hortumlar dahil olmak \u00fczere t\u0131bbi cihazlar\u0131n test edilmesine ili\u015fkin \u00c7in ulusal standartlar\u0131.<\/li>\n<\/ul>\n<p>Bu standartlar, TS-01 test cihaz\u0131n\u0131n d\u00fcnya \u00e7ap\u0131nda kabul g\u00f6rm\u00fc\u015f g\u00fcvenlik, kalite ve performans gerekliliklerine uygunlu\u011funu garanti eder ve bu da onu d\u00fczenlemelere tabi ortamlarda kullan\u0131m i\u00e7in ideal hale getirir.<\/p>\n<hr \/>\n<h2><strong>Destek ve E\u011fitim<\/strong><\/h2>\n<p><a href=\"https:\/\/www.materialstests.com\/tr\/\"><strong>Cell Instruments<\/strong><\/a>\u00a0teklifler\u00a0<strong>kapsaml\u0131 destek<\/strong>\u00a0i\u00e7in\u00a0<strong>TS-01 \u015e\u0131r\u0131nga T\u00fcp\u00fc Sertlik Test Cihaz\u0131<\/strong>, dahil olmak \u00fczere:<\/p>\n<ul>\n<li><strong>Teknik Destek<\/strong>: Sorun giderme ve kalibrasyon i\u00e7in uzman deste\u011fine eri\u015fim.<\/li>\n<li><strong>E\u011fitim<\/strong>: Personele, makinenin nas\u0131l \u00e7al\u0131\u015ft\u0131r\u0131laca\u011f\u0131 ve test sonu\u00e7lar\u0131n\u0131n nas\u0131l yorumlanaca\u011f\u0131 konusunda yerinde veya \u00e7evrimi\u00e7i e\u011fitim.<\/li>\n<li><strong>Yaz\u0131l\u0131m G\u00fcncellemeleri<\/strong>: Makinenin yaz\u0131l\u0131m\u0131n\u0131n d\u00fczenli olarak g\u00fcncellenmesi, i\u015flevselli\u011fi art\u0131rmak ve de\u011fi\u015fen sekt\u00f6r standartlar\u0131na uyumu sa\u011flamak amac\u0131yla yap\u0131l\u0131r.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Overview The\u00a0Syringe Tube Stiffness Tester\u00a0(TS-01)\u00a0is a high-precision testing device designed to measure the stiffness of medical tubing, particularly hypodermic needles and syringes. As\u00a0stiffness\u00a0directly impacts the safety, flexibility, and overall performance of medical tubing, accurate\u00a0stiffness testing\u00a0is essential to ensure that tubing maintains the right balance of mechanical strength and flexibility. Overly stiff tubing can increase the [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[],"standard-category":[],"class_list":["post-2774","products","type-products","status-publish","hentry","products-categories-medical-device-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/products\/2774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/products\/2774\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/media?parent=2774"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/products-categories?post=2774"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/productstags?post=2774"},{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.materialstests.com\/tr\/wp-json\/wp\/v2\/standard-category?post=2774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}