{"id":626,"date":"2025-12-11T05:57:09","date_gmt":"2025-12-11T05:57:09","guid":{"rendered":"https:\/\/www.materialstests.com\/?p=626"},"modified":"2025-12-11T05:57:12","modified_gmt":"2025-12-11T05:57:12","slug":"elastomeric-closures-penetrability-test-vital-component-in-pharmaceutical-packaging-safety","status":"publish","type":"post","link":"https:\/\/www.materialstests.com\/sk\/news\/elastomeric-closures-penetrability-test-vital-component-in-pharmaceutical-packaging-safety.html","title":{"rendered":"Elastom\u00e9rov\u00e9 uz\u00e1very Sk\u00fa\u0161ka priepustnosti: D\u00f4le\u017eit\u00e1 s\u00fa\u010das\u0165 bezpe\u010dnosti farmaceutick\u00fdch obalov"},"content":{"rendered":"<p>Vo svete farmaceutick\u00fdch obalov je integrita syst\u00e9mu uzatv\u00e1rania v\u00fdrobku prvorad\u00e1, najm\u00e4 pokia\u013e ide o injek\u010dn\u00e9 lieky. Elastomerov\u00e9 uz\u00e1very pou\u017e\u00edvan\u00e9 v t\u00fdchto baliacich syst\u00e9moch, zvy\u010dajne vyroben\u00e9 z gumy alebo in\u00fdch pru\u017en\u00fdch materi\u00e1lov, sl\u00fa\u017eia ako kritick\u00e1 bari\u00e9ra medzi liekom a vonkaj\u0161\u00edm prostred\u00edm. Na str\u00e1nke&nbsp;<strong>sk\u00fa\u0161ka priechodnosti elastom\u00e9rov\u00fdch uz\u00e1verov<\/strong>&nbsp;je jednou zo z\u00e1kladn\u00fdch sk\u00fa\u0161ok, ktor\u00e9 sa vykon\u00e1vaj\u00fa na zabezpe\u010denie tesniacej \u00fa\u010dinnosti t\u00fdchto uz\u00e1verov. T\u00fdmto testom sa hodnot\u00ed, ako dobre elastom\u00e9rov\u00fd uz\u00e1ver odol\u00e1 prepichnutiu ihlou a \u010di sa dok\u00e1\u017ee n\u00e1sledne znovu uzavrie\u0165, \u010do je d\u00f4le\u017eit\u00fd faktor na zabezpe\u010denie sterility a bezpe\u010dnosti injek\u010dn\u00fdch liekov.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pre\u010do sa elastom\u00e9rov\u00e9 uz\u00e1very pou\u017e\u00edvaj\u00fa vo farmaceutick\u00fdch obaloch?<\/h2>\n\n\n\n<p>Elastomerov\u00e9 uz\u00e1very s\u00fa z\u00e1kladn\u00fdmi komponentmi pri balen\u00ed injek\u010dn\u00fdch liekov, preto\u017ee vytv\u00e1raj\u00fa bezpe\u010dn\u00e9 a steriln\u00e9 tesnenie injek\u010dn\u00fdch liekoviek, injek\u010dn\u00fdch strieka\u010diek a ampuliek. Tieto uz\u00e1very s\u00fa zvy\u010dajne vyroben\u00e9 z elastom\u00e9rnych materi\u00e1lov, ako je guma, silik\u00f3n alebo podobn\u00e9 polym\u00e9ry, ktor\u00e9 s\u00fa navrhnut\u00e9 tak, aby zabezpe\u010dili tesn\u00e9 utesnenie, ktor\u00e9 chr\u00e1ni obsah n\u00e1doby pred kontamin\u00e1ciou alebo degrad\u00e1ciou.<\/p>\n\n\n\n<p>Tieto uz\u00e1very sa prepichuj\u00fa ihlami, aby sa umo\u017enilo odobratie alebo injek\u010dn\u00e9 podanie lieku, \u010d\u00edm sa ich funk\u010dnos\u0165 st\u00e1va rozhoduj\u00facou pri zachovan\u00ed sterility lieku a bezpe\u010dnosti pacienta. Aby uz\u00e1very v t\u00fdchto prostrediach spo\u013eahlivo fungovali, musia by\u0165 odoln\u00e9 vo\u010di preniknutiu, po prepichnut\u00ed sa musia \u00fa\u010dinne uzatv\u00e1ra\u0165 a poskytova\u0165 primeran\u00fa bari\u00e9ru proti faktorom prostredia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">V\u00fdznam testu priepustnosti elastom\u00e9rov\u00fdch uz\u00e1verov<\/h2>\n\n\n\n<p>Str\u00e1nka&nbsp;<strong>sk\u00fa\u0161ka priechodnosti elastom\u00e9rov\u00fdch uz\u00e1verov<\/strong>&nbsp;je navrhnut\u00fd tak, aby simuloval podmienky, za ktor\u00fdch sa tieto uz\u00e1very pou\u017e\u00edvaj\u00fa v re\u00e1lnych situ\u00e1ci\u00e1ch - ke\u010f ihla prepichne uz\u00e1ver po\u010das pod\u00e1vania lieku. Testom sa meria odolnos\u0165 materi\u00e1lu uz\u00e1veru vo\u010di prepichnutiu a hodnot\u00ed sa, \u010di sa materi\u00e1l dok\u00e1\u017ee po viacn\u00e1sobnom prepichnut\u00ed znovu uzavrie\u0165 bez toho, aby sa naru\u0161ila celistvos\u0165 n\u00e1dobky s liekom.<\/p>\n\n\n\n<p>\u00daspe\u0161n\u00fd test zaru\u010duje, \u017ee elastom\u00e9rov\u00fd uz\u00e1ver nielen\u017ee udr\u017e\u00ed tesnos\u0165, ale aj zabr\u00e1ni kontamin\u00e1cii z vonkaj\u0161\u00edch zdrojov, ako s\u00fa bakt\u00e9rie alebo pevn\u00e9 \u010dastice. Preto je test k\u013e\u00fa\u010dov\u00fdm krokom pri zabezpe\u010dovan\u00ed bezpe\u010dnosti a kvality injek\u010dn\u00fdch liekov, preto\u017ee naru\u0161en\u00fd uz\u00e1ver by mohol vies\u0165 ku kontamin\u00e1cii alebo \u00faniku lieku, \u010do by mohlo ma\u0165 v\u00e1\u017ene n\u00e1sledky na zdravie pacienta.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ako sa normy USP 381 uplat\u0148uj\u00fa na elastom\u00e9rov\u00e9 uz\u00e1very<\/h2>\n\n\n\n<p>Str\u00e1nka&nbsp;<strong>USP 381<\/strong>&nbsp;je v\u0161eobecne uzn\u00e1van\u00e1 norma, ktor\u00e1 stanovuje po\u017eiadavky na testovanie elastom\u00e9rov\u00fdch uz\u00e1verov pou\u017e\u00edvan\u00fdch vo farmaceutick\u00fdch obaloch. Konkr\u00e9tne poskytuje usmernenia na pos\u00fadenie odolnosti vo\u010di prepichnutiu a tesniacej schopnosti uz\u00e1verov, \u010d\u00edm sa zabezpe\u010duje, \u017ee sp\u013a\u0148aj\u00fa potrebn\u00e9 krit\u00e9ri\u00e1 na pou\u017eitie pri balen\u00ed injek\u010dn\u00fdch liekov.<\/p>\n\n\n\n<p>Pod&nbsp;<strong>USP 381<\/strong>, elastom\u00e9rov\u00e9 uz\u00e1very musia preuk\u00e1za\u0165, \u017ee vydr\u017eia viacn\u00e1sobn\u00e9 prepichnutie ihlou bez straty tesniacej integrity. T\u00e1to norma je ve\u013emi d\u00f4le\u017eit\u00e1, preto\u017ee injek\u010dn\u00e9 lieky musia zosta\u0165 steriln\u00e9 po\u010das celej doby ich skladovania a po\u010das procesu pod\u00e1vania. Dodr\u017eiavan\u00edm noriem USP 381 m\u00f4\u017eu v\u00fdrobcovia zabezpe\u010di\u0165, aby ich uz\u00e1very sp\u013a\u0148ali pr\u00edsne regula\u010dn\u00e9 po\u017eiadavky na bezpe\u010dnos\u0165 pacientov a \u00fa\u010dinnos\u0165 liekov.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vykonanie testu priepustnosti elastom\u00e9rov\u00fdch uz\u00e1verov<\/h2>\n\n\n\n<p>Sk\u00fa\u0161ka priepustnosti elastom\u00e9rov\u00fdch uz\u00e1verov zvy\u010dajne zah\u0155\u0148a tieto kroky:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Pr\u00edprava vzorky<\/strong>: Na injek\u010dn\u00fa liekovku alebo strieka\u010dku sa nasad\u00ed uz\u00e1ver, napr\u00edklad gumov\u00e1 z\u00e1tka alebo elastom\u00e9rov\u00fd uz\u00e1ver, a bezpe\u010dne sa umiestni na testovac\u00ed stroj.<\/li>\n\n\n\n<li><strong>Zavedenie ihly<\/strong>: Do uz\u00e1veru sa za kontrolovan\u00fdch podmienok zavedie ihla. Sila potrebn\u00e1 na prepichnutie uz\u00e1veru sa meria pomocou silomeru alebo sn\u00edma\u010da za\u0165a\u017eenia.<\/li>\n\n\n\n<li><strong>Test op\u00e4tovn\u00e9ho utesnenia<\/strong>: Po prepichnut\u00ed sa testuje schopnos\u0165 uz\u00e1veru znovu sa uzavrie\u0165 tak, \u017ee sa odstr\u00e1ni ihla a zmeria sa, \u010di si uz\u00e1ver zachov\u00e1va svoju celistvos\u0165 a zabra\u0148uje \u00faniku alebo kontamin\u00e1cii lieku.<\/li>\n<\/ol>\n\n\n\n<p>Test \u010dasto zah\u0155\u0148a viacn\u00e1sobn\u00e9 opakovanie procesu prepichnutia s cie\u013eom simulova\u0165 re\u00e1lne pou\u017e\u00edvanie a vyhodnoti\u0165, ako dobre uz\u00e1ver funguje po opakovanom prepichnut\u00ed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Tester vpichov ihlou NPT-01: Rie\u0161enie pre testovanie elastom\u00e9rov\u00fdch uz\u00e1verov<\/h2>\n\n\n\n<p>Zabezpe\u010di\u0165 s\u00falad s&nbsp;<strong>USP 381<\/strong>&nbsp;a udr\u017eiava\u0165 vysokokvalitn\u00e9 \u0161tandardy balenia, sa v\u00fdrobcovia liekov spoliehaj\u00fa na presn\u00e9 a spo\u013eahliv\u00e9 testovacie zariadenia. Na str\u00e1nke&nbsp;<strong>NPT-01 Tester vpichu ihly<\/strong>&nbsp;je \u0161peci\u00e1lne navrhnut\u00fd na hodnotenie odolnosti elastom\u00e9rov\u00fdch uz\u00e1verov proti prepichnutiu. Tento pr\u00edstroj je pre v\u00fdrobcov k\u013e\u00fa\u010dov\u00fdm n\u00e1strojom, preto\u017ee pom\u00e1ha ur\u010di\u0165, \u010di uz\u00e1very sp\u013a\u0148aj\u00fa pr\u00edsne normy pre v\u00fdkon a integritu uveden\u00e9 v USP 381.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">K\u013e\u00fa\u010dov\u00e9 vlastnosti testera vpichov ihlou NPT-01<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>V\u0161estrannos\u0165<\/strong>: Pr\u00edstroj NPT-01 je vybaven\u00fd viacer\u00fdmi typmi ihiel a pr\u00edpravkami na dr\u017eanie vzoriek, \u010do umo\u017e\u0148uje prisp\u00f4sobi\u0165 ho na testovanie r\u00f4znych typov elastom\u00e9rov\u00fdch uz\u00e1verov.<\/li>\n\n\n\n<li><strong>Presnos\u0165<\/strong>: Pr\u00edstroj vyu\u017e\u00edva presn\u00fa gu\u013e\u00f4\u010dkov\u00fa skrutku a syst\u00e9m krokov\u00e9ho motora na zabezpe\u010denie konzistentn\u00e9ho a presn\u00e9ho merania sily vpichu.<\/li>\n\n\n\n<li><strong>Monitorovanie \u00fadajov<\/strong>: NPT-01 m\u00e1 u\u017e\u00edvate\u013esky pr\u00edvetiv\u00e9 rozhranie HMI s dotykovou obrazovkou a poskytuje monitorovanie \u00fadajov v re\u00e1lnom \u010dase, \u010do umo\u017e\u0148uje oper\u00e1torom jednoducho sledova\u0165 v\u00fdsledky testov.<\/li>\n\n\n\n<li><strong>Dodr\u017eiavanie predpisov<\/strong>: NPT-01 je navrhnut\u00fd tak, aby sp\u013a\u0148al priemyseln\u00e9 normy, ako napr\u00edklad\u00a0<strong>USP 381<\/strong>, a poskytuje spo\u013eahliv\u00e9 rie\u0161enie na vykon\u00e1vanie sk\u00fa\u0161ok priechodnosti elastom\u00e9rov\u00fdch uz\u00e1verov.<\/li>\n\n\n\n<li><strong>Bezpe\u010dnos\u0165<\/strong>: V\u010faka zabudovan\u00fdm bezpe\u010dnostn\u00fdm funkci\u00e1m, ako je ochrana proti pre\u0165a\u017eeniu a obmedzova\u010d polohy, tester zabezpe\u010duje bezpe\u010dn\u00e9 a efekt\u00edvne testovanie.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">V\u00fdhody pou\u017e\u00edvania testera vpichov ihlou NPT-01<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Zv\u00fd\u0161en\u00e1 spo\u013eahlivos\u0165<\/strong>: NPT-01 zabezpe\u010duje, \u017ee uz\u00e1very sa testuj\u00fa za konzistentn\u00fdch a opakovate\u013en\u00fdch podmienok, \u010d\u00edm sa zvy\u0161uje spo\u013eahlivos\u0165 v\u00fdsledkov testov.<\/li>\n\n\n\n<li><strong>Zlep\u0161en\u00e9 dodr\u017eiavanie predpisov<\/strong>: S jeho s\u00faladom s\u00a0<strong>USP 381<\/strong>\u00a0a \u010fal\u0161ie pr\u00edslu\u0161n\u00e9 normy, NPT-01 pom\u00e1ha v\u00fdrobcom sp\u013a\u0148a\u0165 regula\u010dn\u00e9 po\u017eiadavky na farmaceutick\u00e9 obaly.<\/li>\n\n\n\n<li><strong>Zv\u00fd\u0161en\u00e1 efekt\u00edvnos\u0165<\/strong>: NPT-01 je navrhnut\u00fd pre vysok\u00fa priepustnos\u0165, tak\u017ee je ide\u00e1lny pre v\u00fdrobcov, ktor\u00ed vy\u017eaduj\u00fa r\u00fdchle a presn\u00e9 testovanie viacer\u00fdch vzoriek.<\/li>\n\n\n\n<li><strong>Komplexn\u00e9 testovanie<\/strong>: Tester poskytuje komplexn\u00fd s\u00fabor testov vr\u00e1tane merania sily prepichnutia a hodnotenia op\u00e4tovn\u00e9ho utesnenia, \u010d\u00edm zabezpe\u010duje d\u00f4kladn\u00e9 hodnotenie v\u00fdkonu uz\u00e1veru.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u00daloha testovania priepustnosti v oblasti bezpe\u010dnosti pacientov<\/h2>\n\n\n\n<p>Testovanie priepustnosti zohr\u00e1va rozhoduj\u00facu \u00falohu pri zabezpe\u010dovan\u00ed toho, aby elastom\u00e9rov\u00e9 uz\u00e1very odolali mechanick\u00fdm sil\u00e1m pri pod\u00e1van\u00ed liekov a z\u00e1rove\u0148 si zachovali integritu tesnenia. Tento proces je obzvl\u00e1\u0161\u0165 d\u00f4le\u017eit\u00fd v s\u00favislosti s injek\u010dn\u00fdmi liekmi, kde by zlyhanie spr\u00e1vneho utesnenia obalu mohlo ma\u0165 za n\u00e1sledok kontamin\u00e1ciu alebo \u00fanik, \u010do m\u00f4\u017ee ohrozi\u0165 bezpe\u010dnos\u0165 pacienta.<\/p>\n\n\n\n<p>Vykonan\u00edm testu priechodnosti elastom\u00e9rov\u00fdch uz\u00e1verov pomocou zariadenia, ako je napr.&nbsp;<strong>NPT-01 Tester vpichu ihly<\/strong>, m\u00f4\u017eu v\u00fdrobcovia liekov s istotou zabezpe\u010di\u0165, aby ich obaly sp\u013a\u0148ali pr\u00edsne po\u017eiadavky na v\u00fdkon&nbsp;<strong>USP 381<\/strong>. To pom\u00e1ha chr\u00e1ni\u0165 liek aj pacienta pred rizikami spojen\u00fdmi s po\u0161koden\u00fdmi uz\u00e1vermi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Z\u00e1ver: Ochrana farmaceutickej integrity<\/h2>\n\n\n\n<p>Str\u00e1nka&nbsp;<strong>sk\u00fa\u0161ka priechodnosti elastom\u00e9rov\u00fdch uz\u00e1verov<\/strong>&nbsp;je d\u00f4le\u017eitou s\u00fa\u010das\u0165ou procesu kontroly kvality farmaceutick\u00fdch obalov. Hodnoten\u00edm schopnosti uz\u00e1verov odol\u00e1va\u0165 prepichnutiu a op\u00e4tovn\u00e9mu uzatvoreniu po prepichnut\u00ed m\u00f4\u017eu v\u00fdrobcovia zabezpe\u010di\u0165, aby injek\u010dn\u00e9 lieky zostali bezpe\u010dn\u00e9 a \u00fa\u010dinn\u00e9 po\u010das cel\u00e9ho \u017eivotn\u00e9ho cyklu. Testovanie v s\u00falade s&nbsp;<strong>USP 381<\/strong>&nbsp;normy s\u00fa rozhoduj\u00face pre zachovanie sterility a integrity liekov.<\/p>\n\n\n\n<p>S pokro\u010dil\u00fdmi testovac\u00edmi pr\u00edstrojmi, ako je napr.&nbsp;<strong>NPT-01 Tester vpichu ihly<\/strong>, m\u00f4\u017eu v\u00fdrobcovia spo\u013eahlivo pos\u00fadi\u0165 v\u00fdkonnos\u0165 elastom\u00e9rov\u00fdch uz\u00e1verov a splni\u0165 vysok\u00e9 normy vy\u017eadovan\u00e9 z h\u013eadiska bezpe\u010dnosti pacientov.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">\u010cASTO KLADEN\u00c9 OT\u00c1ZKY<\/h2>\n\n\n\n<p><strong>1. \u010co je sk\u00fa\u0161ka priechodnosti elastom\u00e9rov\u00fdch uz\u00e1verov?<\/strong><br>T\u00fdmto testom sa hodnot\u00ed, ako dobre elastom\u00e9rov\u00e9 uz\u00e1very odol\u00e1vaj\u00fa prepichnutiu ihlami a \u010di sa dok\u00e1\u017eu n\u00e1sledne znovu uzavrie\u0165, aby sa zachovala celistvos\u0165 n\u00e1doby s liekom.<\/p>\n\n\n\n<p><strong>2. Ako USP 381 ovplyv\u0148uje testovanie elastom\u00e9rov\u00fdch uz\u00e1verov?<\/strong><br>V dokumente USP 381 s\u00fa uveden\u00e9 po\u017eiadavky na v\u00fdkonnos\u0165 elastom\u00e9rov\u00fdch uz\u00e1verov pou\u017e\u00edvan\u00fdch v injek\u010dn\u00fdch obaloch na lieky, ktor\u00e9 zabezpe\u010duj\u00fa, aby uz\u00e1very sp\u013a\u0148ali pr\u00edsne normy odolnosti proti prepichnutiu a schopnosti op\u00e4tovn\u00e9ho utesnenia.<\/p>\n\n\n\n<p><strong>3. \u010co rob\u00ed tester vpichov ihlou NPT-01?<\/strong><br>NPT-01 je testovac\u00ed pr\u00edstroj ur\u010den\u00fd na simul\u00e1ciu prepichnutia elastom\u00e9rov\u00fdch uz\u00e1verov ihlou, meranie sily prepichnutia a hodnotenie schopnosti uz\u00e1veru po prepichnut\u00ed znovu sa uzavrie\u0165.<\/p>\n\n\n\n<p><strong>4. Pre\u010do je op\u00e4tovn\u00e9 utesnenie d\u00f4le\u017eit\u00e9 pre elastom\u00e9rov\u00e9 uz\u00e1very?<\/strong><br>Op\u00e4tovn\u00e9 utesnenie zabezpe\u010duje, aby uz\u00e1ver po prepichnut\u00ed na\u010falej chr\u00e1nil liek pred kontamin\u00e1ciou alebo \u00fanikom, \u010d\u00edm sa zachov\u00e1 sterilita a \u00fa\u010dinnos\u0165 lieku.<\/p>\n\n\n\n<p><strong>5. Ko\u013eko prepichnut\u00ed vydr\u017e\u00ed elastom\u00e9rov\u00fd uz\u00e1ver?<\/strong><br>Po\u010det prepichnut\u00ed, ktor\u00e9 uz\u00e1ver vydr\u017e\u00ed, z\u00e1vis\u00ed od materi\u00e1lu a kon\u0161trukcie. Uz\u00e1very v\u0161ak musia sp\u013a\u0148a\u0165&nbsp;<strong>USP 381<\/strong>&nbsp;krit\u00e9ri\u00e1 odolnosti vo\u010di prepichnutiu a op\u00e4tovn\u00e9mu utesneniu, aby sa zabezpe\u010dila bezpe\u010dnos\u0165 pacienta.<\/p>","protected":false},"excerpt":{"rendered":"<p>In the world of pharmaceutical packaging, the integrity of a product\u2019s closure system is paramount, especially when it comes to injectable medications. The elastomeric closures used in these packaging systems, typically made of rubber or other flexible materials, serve as a critical barrier between the drug and the outside environment. The&nbsp;elastomeric closures penetrability test&nbsp;is one [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-626","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/posts\/626","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/comments?post=626"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/posts\/626\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/media?parent=626"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/categories?post=626"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.materialstests.com\/sk\/wp-json\/wp\/v2\/tags?post=626"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}