{"id":2779,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/ntt-01-needle-toughness-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"ntt-01-needle-toughness-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/ro\/products\/ntt-01-needle-toughness-tester.html","title":{"rendered":"NTT-01 Tester de duritate a acului"},"content":{"rendered":"<h2>Prezentare general\u0103<\/h2>\n<p>The\u00a0<strong>NTT-01\u00a0<a href=\"https:\/\/www.materialstests.com\/ro\/medical-device-tester.html\/\">Tester de duritate a acului<\/a><\/strong>\u00a0este un instrument de testare avansat conceput pentru a evalua rezisten\u021ba la \u00eencovoiere a acelor hipodermice \u00een condi\u021bii de stres controlate. \u00cen conformitate cu liniile directoare ale\u00a0<strong>ISO 9626:2016<\/strong>, acest sistem de testare asigur\u0103 men\u021binerea integrit\u0103\u021bii acelor hipodermice \u00een timpul procesului de introducere \u0219i retragere, esen\u021biale pentru utilizarea lor \u00een siguran\u021b\u0103 \u00een aplica\u021bii medicale. Testerul ofer\u0103 un control precis asupra procesului de testare, simul\u00e2nd for\u021bele mecanice cu care se confrunt\u0103 acele \u00een condi\u021bii reale.\u00a0<strong>Tester de duritate a acului medical<\/strong>\u00a0este potrivit pentru m\u0103surarea rezisten\u021bei tuburilor acului de injec\u021bie intradermic, subcutanat, muscular \u0219i intravenos uman \u0219i a altor tuburi rigide din o\u021bel inoxidabil pentru echipamente medicale.<\/p>\n<p>Cu un\u00a0<strong>Controlat de PLC<\/strong>\u00a0sistem \u0219i un\u00a0<strong>Interfa\u021b\u0103 HMI cu ecran tactil<\/strong>, NTT-01\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>ofer\u0103 o experien\u021b\u0103 f\u0103r\u0103 \u00eentreruperi \u0219i u\u0219or de utilizat pentru efectuarea de teste repetabile \u0219i precise. Este conceput special pentru a determina rezisten\u021ba la \u00eencovoiere a acelor hipodermice, asigur\u00e2nd conformitatea cu standardele interna\u021bionale \u0219i confirm\u00e2nd durabilitatea \u0219i fiabilitatea dispozitivelor medicale.<\/p>\n<hr \/>\n<h2>Aplica\u021bii<\/h2>\n<p>The\u00a0<strong>NTT-01 Tester de duritate a acului<\/strong>\u00a0este indispensabil pentru\u00a0<strong>fabricarea dispozitivelor medicale<\/strong>\u00a0\u00een special \u00een produc\u021bia \u0219i asigurarea calit\u0103\u021bii acelor hipodermice. Principala sa aplica\u021bie este evaluarea\u00a0<strong>rezisten\u021b\u0103 la \u00eencovoiere<\/strong>\u00a0de ace realizate din diferite materiale \u0219i grosimi ale pere\u021bilor. Testerul joac\u0103 un rol esen\u021bial \u00een urm\u0103toarele sectoare:<\/p>\n<ul>\n<li><strong>Fabricarea acelor hipodermice<\/strong>: Asigur\u0103 c\u0103 acele pot rezista la solicit\u0103ri mecanice f\u0103r\u0103 s\u0103 se rup\u0103 sau s\u0103 se deformeze.<\/li>\n<li><strong>Controlul calit\u0103\u021bii \u00een testarea dispozitivelor medicale<\/strong>: Vital pentru conformitatea cu\u00a0<strong>ISO 9626<\/strong>\u00a0\u0219i alte standarde interna\u021bionale.<\/li>\n<li><strong>Cercetare \u0219i dezvoltare (C&amp;D)<\/strong>: Contribuie la dezvoltarea de noi modele de ace cu durabilitate sporit\u0103.<\/li>\n<li><strong>Testarea ambalajelor<\/strong>: Verific\u0103 integritatea solu\u021biilor de ambalare medical\u0103 care implic\u0103 ace.<\/li>\n<\/ul>\n<p>Prin simularea precis\u0103 a for\u021belor pe care acele le suport\u0103 \u00een timpul inser\u021biei, retragerii \u0219i utiliz\u0103rii, sistemul\u00a0<strong>NTT-01<\/strong>\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>permite produc\u0103torilor s\u0103 garanteze siguran\u021ba \u0219i eficacitatea produselor lor.<\/p>\n<hr \/>\n<h2>Necesitate<\/h2>\n<p>Acele hipodermice sunt expuse la solicit\u0103ri mecanice semnificative \u00een timpul utiliz\u0103rii, at\u00e2t \u00een timpul introducerii \u00een piele, c\u00e2t \u0219i \u00een timpul retragerii. Aceste for\u021be pot face ca acul s\u0103 se \u00eendoaie, s\u0103 se rup\u0103 sau s\u0103 se deformeze, compromi\u021b\u00e2nd at\u00e2t eficien\u021ba procedurilor medicale, c\u00e2t \u0219i siguran\u021ba pacientului.<\/p>\n<p><strong>De ce testerul de duritate a acului NTT-01 este crucial:<\/strong><\/p>\n<ul>\n<li><strong>Asigurarea calit\u0103\u021bii<\/strong>: Se asigur\u0103 c\u0103 acele \u00eendeplinesc cerin\u021bele stricte de durabilitate specificate \u00een ISO 9626.<\/li>\n<li><strong>Siguran\u021b\u0103<\/strong>: Reduce riscul de rupere \u00een timpul procedurilor medicale, prevenind eventualele v\u0103t\u0103m\u0103ri ale pacien\u021bilor.<\/li>\n<li><strong>Conformitate<\/strong>: Asigur\u0103 respectarea standardelor recunoscute la nivel interna\u021bional, cum ar fi\u00a0<strong>ISO 9626<\/strong>, care guverneaz\u0103 performan\u021bele mecanice ale acelor medicale.<\/li>\n<\/ul>\n<p>F\u0103r\u0103 acest proces de testare, produc\u0103torii nu pot garanta performan\u021ba \u0219i siguran\u021ba acelor lor hipodermice, ceea ce face ca\u00a0<strong>NTT-01<\/strong>\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>esen\u021biale pentru controlul calit\u0103\u021bii \u00een fabricarea dispozitivelor medicale.<\/p>\n<hr \/>\n<h2>Principiul de func\u021bionare<\/h2>\n<p>The\u00a0<strong>NTT-01 Tester de duritate a acului<\/strong>\u00a0func\u021bioneaz\u0103 pe baza unui principiu simplu, dar extrem de eficient. Sistemul presupune fixarea unui cap\u0103t al unui ac hipodermic (sau al unui tub) \u0219i aplicarea unei for\u021be la o anumit\u0103 distan\u021b\u0103 de punctul de fixare pentru a \u00eendoi acul. \u00cendoirea se face \u00een ambele direc\u021bii (\u00eenainte \u0219i \u00eenapoi) pentru a simula for\u021bele mecanice reale la care ar fi supus acul \u00een timpul utiliz\u0103rii.<\/p>\n<ul>\n<li><strong>Procedura de testare<\/strong>: O for\u021b\u0103 controlat\u0103 este aplicat\u0103 pentru a \u00eendoi tubul acului la unghiuri specifice de\u00a0<strong>15\u00b0<\/strong>,\u00a0<strong>20\u00b0<\/strong>, sau\u00a0<strong>25\u00b0<\/strong>, \u00een func\u021bie de grosimea peretelui tubului (conform\u00a0<strong>ISO 9626<\/strong>\u00a0standard).<\/li>\n<li><strong>Modul de \u00eendoire<\/strong>: Sunt disponibile ambele moduri de \u00eendoire, unidirec\u021bional \u0219i bidirec\u021bional, pentru simularea diferitelor solicit\u0103ri mecanice pe care le suport\u0103 acele.<\/li>\n<li><strong>Controlul frecven\u021bei \u0219i al timpului de permanen\u021b\u0103<\/strong>: NTT-01\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>permite controlul precis al frecven\u021bei de testare (setat la\u00a0<strong>0,5 Hz<\/strong>) \u0219i timpul de a\u0219teptare \u00eentre cicluri pentru a simula procesul de \u00eendoire pe perioade lungi.<\/li>\n<\/ul>\n<p>The\u00a0<strong>NTT-01<\/strong>\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>reproduce \u00een mod eficient stresul mecanic cu care se confrunt\u0103 acele \u00een mediile medicale reale, oferind produc\u0103torilor un rezultat de testare extrem de precis pentru a evalua rezisten\u021ba \u0219i duritatea acelor.<\/p>\n<hr \/>\n<h2>Specifica\u021bii tehnice<\/h2>\n<p><strong>Caracteristici principale:<\/strong><\/p>\n<ul>\n<li><strong>Sistemul de control<\/strong>: Controlat de PLC cu un ecran tactil HMI de 7 inch pentru operare intuitiv\u0103.<\/li>\n<li><strong>Unghiuri de \u00eendoire<\/strong>: Reglabil la\u00a0<strong>15\u00b0<\/strong>,\u00a0<strong>20\u00b0<\/strong>, \u0219i\u00a0<strong>25\u00b0<\/strong>\u00a0pentru a acomoda diferite tipuri de ace.<\/li>\n<li><strong>Frecven\u021ba de testare<\/strong>:\u00a0<strong>0,5 Hz<\/strong>\u00a0pentru simularea precis\u0103 a ciclurilor de \u00eendoire.<\/li>\n<li><strong>Modul de \u00eendoire<\/strong>: Suport\u0103 at\u00e2t\u00a0<strong>unidirec\u021bional<\/strong>\u00a0\u0219i\u00a0<strong>bidirec\u021bional<\/strong>\u00a0\u00eendoire.<\/li>\n<li><strong>Surs\u0103 de alimentare<\/strong>: Func\u021bioneaz\u0103 pe\u00a0<strong>110V-220V<\/strong>\u00a0pentru a asigura compatibilitatea global\u0103.<\/li>\n<\/ul>\n<p><strong>Parametrii cheie:<\/strong><\/p>\n<ul>\n<li><strong>Op\u021biuni pentru unghiul de testare<\/strong>: 15\u00b0, 20\u00b0, 25\u00b0.<\/li>\n<li><strong>Controlul frecven\u021bei<\/strong>: Fixat la 0,5 Hz.<\/li>\n<li><strong>Modul de \u00eendoire<\/strong>: \u00cencovoiere bidirec\u021bional\u0103 \u0219i unidirec\u021bional\u0103.<\/li>\n<li><strong>Timp de sta\u021bionare<\/strong>: Reglabil pentru un control mai precis al ciclurilor de \u00eendoire.<\/li>\n<li><strong>Surs\u0103 de alimentare<\/strong>: 110-220V, asigur\u00e2nd utilizarea \u00een \u00eentreaga lume.<\/li>\n<\/ul>\n<p>Aceast\u0103 combina\u021bie de caracteristici face ca\u00a0<strong>NTT-01 Tester de duritate a acului<\/strong>\u00a0ideal at\u00e2t pentru verific\u0103ri de rutin\u0103 ale controlului calit\u0103\u021bii, c\u00e2t \u0219i pentru aplica\u021bii de cercetare detaliate.<\/p>\n<h2>Avantaje<\/h2>\n<p>The\u00a0<strong>NTT-01 Tester de duritate a acului<\/strong>\u00a0ofer\u0103 c\u00e2teva avantaje distincte care \u00eel fac alegerea preferat\u0103 pentru testarea acelor hipodermice:<\/p>\n<ul>\n<li><strong>Precizie ridicat\u0103<\/strong>: Testerul asigur\u0103 unghiuri exacte de \u00eendoire \u0219i aplicarea for\u021bei, esen\u021biale pentru ob\u021binerea unor rezultate precise \u0219i reproductibile.<\/li>\n<li><strong>Operare u\u0219oar\u0103<\/strong>: Cu o interfa\u021b\u0103 intuitiv\u0103\u00a0<strong>Interfa\u021b\u0103 HMI cu ecran tactil<\/strong>, operatorii pot configura cu u\u0219urin\u021b\u0103 testele, pot monitoriza rezultatele \u0219i pot ajusta parametrii f\u0103r\u0103 a fi nevoie de instruire complex\u0103.<\/li>\n<li><strong>Testare versatil\u0103<\/strong>: Suport\u0103 mai multe moduri \u0219i unghiuri de \u00eendoire, ceea ce \u00eel face potrivit pentru diferite tipuri de ace hipodermice, inclusiv variante cu pere\u021bi sub\u021biri \u0219i extra-sub\u021biri.<\/li>\n<li><strong>Conformitatea cu standardele<\/strong>: \u00cendepline\u0219te cerin\u021bele de testare descrise \u00een\u00a0<strong>ISO 9626<\/strong>\u00a0Anexa C, asigur\u00e2ndu-se c\u0103 acele testate cu NTT-01 \u00eendeplinesc standardele interna\u021bionale de calitate.<\/li>\n<li><strong>Siguran\u021b\u0103<\/strong>: Prin simularea for\u021belor mecanice pe care le experimenteaz\u0103 acele,\u00a0<strong>NTT-01<\/strong>\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>ajut\u0103 produc\u0103torii s\u0103 evite poten\u021biala rupere a acului, reduc\u00e2nd riscul de r\u0103nire a pacien\u021bilor.<\/li>\n<li><strong>Rezultate fiabile<\/strong>: Cu\u00a0<strong>Sistem controlat de PLC<\/strong>\u00a0\u0219i\u00a0<strong>control precis al frecven\u021bei<\/strong>, a\u00a0<strong>NTT-01<\/strong>\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>asigur\u0103 rezultate exacte cu o marj\u0103 de eroare minim\u0103.<\/li>\n<\/ul>\n<hr \/>\n<h2>Configura\u021bii \u0219i accesorii<\/h2>\n<p>The\u00a0<strong>NTT-01 Tester de duritate a acului<\/strong>\u00a0este complet echipat pentru a face fa\u021b\u0103 cerin\u021belor riguroase de testare:<\/p>\n<ul>\n<li><strong>Unitate de testare a durit\u0103\u021bii acului<\/strong>: Ma\u0219ina principal\u0103 de testare.<\/li>\n<li><strong>Caliper<\/strong>: Folosit pentru m\u0103surarea grosimii acelor pentru a se asigura c\u0103 acestea sunt conforme cu standardele specificate.<\/li>\n<li><strong>Cablu de alimentare<\/strong>: Pentru conectarea testerului la sursele de alimentare.<\/li>\n<li><strong>Siguran\u021b\u0103<\/strong>: Pentru a proteja \u00eempotriva fluctua\u021biilor electrice.<\/li>\n<\/ul>\n<p>Accesoriile \u0219i configura\u021biile suplimentare sunt disponibile la cerere pentru a r\u0103spunde nevoilor specifice de testare.<\/p>\n<hr \/>\n<h2>Standarde<\/h2>\n<p>The\u00a0<strong>NTT-01 Tester de duritate a acului<\/strong>\u00a0respect\u0103 mai multe standarde interna\u021bionale cheie pentru a asigura fiabilitatea \u0219i consecven\u021ba procedurilor de testare:<\/p>\n<ul>\n<li><strong>ISO 9626:2016<\/strong>: Acest standard interna\u021bional specific\u0103 cerin\u021bele pentru propriet\u0103\u021bile mecanice ale acelor hipodermice, inclusiv testul de \u00eendoire utilizat pentru evaluarea rezisten\u021bei acului.<\/li>\n<li><strong>GB\/T 18457<\/strong>: Standard chinez care descrie, de asemenea, metodele de testare mecanic\u0103 a acelor medicale.<\/li>\n<\/ul>\n<p>Aceste standarde garanteaz\u0103 c\u0103\u00a0<strong>NTT-01<\/strong>\u00a0<strong>Tester de duritate a acului\u00a0<\/strong>ofer\u0103 rezultate de testare precise \u0219i conforme care \u00eendeplinesc cerin\u021bele globale.<\/p>\n<h2>Asisten\u021b\u0103 \u0219i formare<\/h2>\n<p><strong>Cell Instruments<\/strong>\u00a0ofer\u0103 servicii complete de asisten\u021b\u0103 \u0219i instruire pentru a asigura utilizarea optim\u0103 a\u00a0<strong>NTT-01 Tester de duritate a acului<\/strong>. Exper\u021bii no\u0219tri sunt disponibili pentru:<\/p>\n<ul>\n<li><strong>Instalare<\/strong>: Suport pentru instalare la fa\u021ba locului sau de la distan\u021b\u0103.<\/li>\n<li><strong>Formarea utilizatorilor<\/strong>: Programe de instruire personalizate pentru a v\u0103 asigura c\u0103 echipa dumneavoastr\u0103 poate utiliza sistemul \u00een mod eficient.<\/li>\n<li><strong>Asisten\u021b\u0103 tehnic\u0103<\/strong>: Asisten\u021b\u0103 tehnic\u0103 continu\u0103, inclusiv depanare \u0219i \u00eentre\u021binere, pentru a maximiza durata de via\u021b\u0103 a testerului dvs.<\/li>\n<li><strong>Calibrare \u0219i certificare<\/strong>: Servicii regulate de calibrare pentru a men\u021bine precizia \u0219i conformitatea cu standardele industriale.<\/li>\n<\/ul>\n<hr \/>\n<h2>\u00centreb\u0103ri frecvente (FAQ)<\/h2>\n<ol>\n<li><strong>Ce tipuri de ace poate testa NTT-01?<\/strong>\n<ul>\n<li>The\u00a0<strong>NTT-01<\/strong>\u00a0este proiectat pentru testarea acelor hipodermice cu diferite grosimi ale peretelui, inclusiv tipuri cu pere\u021bi normali, cu pere\u021bi sub\u021biri \u0219i cu pere\u021bi foarte sub\u021biri.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Ce standarde respect\u0103 NTT-01?<\/strong>\n<ul>\n<li>The\u00a0<strong>NTT-01<\/strong>\u00a0\u00eendepline\u0219te cerin\u021bele\u00a0<strong>ISO 9626<\/strong>\u00a0\u0219i\u00a0<strong>GB\/T 18457<\/strong>\u00a0pentru testarea rezisten\u021bei la \u00eencovoiere a acelor hipodermice.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Cum se seteaz\u0103 unghiul de \u00eendoire?<\/strong>\n<ul>\n<li>Unghiul de \u00eendoire poate fi reglat la\u00a0<strong>15\u00b0<\/strong>,\u00a0<strong>20\u00b0<\/strong>, sau\u00a0<strong>25\u00b0<\/strong>, \u00een func\u021bie de tipul de ac testat.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Poate NTT-01 s\u0103 simuleze condi\u021biile din lumea real\u0103?<\/strong>\n<ul>\n<li>Da, testerul simuleaz\u0103 cu exactitate for\u021bele mecanice la care sunt supuse acele \u00een timpul inser\u021biei \u0219i retragerii, asigur\u00e2nd rezultate realiste ale testelor.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Este NTT-01 u\u0219or de utilizat?<\/strong>\n<ul>\n<li>Da, cu\u00a0<strong>Interfa\u021b\u0103 HMI cu ecran tactil<\/strong>\u00a0\u0219i\u00a0<strong>Control PLC<\/strong>, NTT-01 este proiectat pentru o utilizare u\u0219oar\u0103, necesit\u00e2nd o instruire minim\u0103.<\/li>\n<\/ul>\n<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Overview The\u00a0NTT-01\u00a0Needle Toughness Tester\u00a0is an advanced testing instrument designed to evaluate the bending resistance of hypodermic needles under controlled stress conditions. Following the guidelines of\u00a0ISO 9626:2016, this testing system ensures that hypodermic needles maintain their integrity during the insertion and withdrawal process, critical for their safe use in medical applications. The tester offers precise control [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[],"class_list":["post-2779","products","type-products","status-publish","hentry","products-categories-medical-device-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products\/2779","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products\/2779\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/media?parent=2779"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products-categories?post=2779"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/productstags?post=2779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}