{"id":2774,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/ts-01-syringe-tube-stiffness-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"ts-01-syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/ro\/products\/ts-01-syringe-tube-stiffness-tester.html","title":{"rendered":"TS-01 Tester de rigiditate a tubului de sering\u0103"},"content":{"rendered":"<h2><strong>Prezentare general\u0103<\/strong><\/h2>\n<p>The\u00a0<strong><a href=\"https:\/\/www.materialstests.com\/ro\/medical-device-tester.html\/\">Tester de rigiditate a tubului seringii<\/a>\u00a0(TS-01)<\/strong>\u00a0este un dispozitiv de testare de \u00eenalt\u0103 precizie conceput pentru a m\u0103sura rigiditatea tuburilor medicale, \u00een special a acelor hipodermice \u0219i a seringilor. Ca\u00a0<strong>rigiditate<\/strong>\u00a0are un impact direct asupra siguran\u021bei, flexibilit\u0103\u021bii \u0219i performan\u021bei generale a tuburilor medicale, precise\u00a0<strong>testarea rigidit\u0103\u021bii<\/strong>\u00a0este esen\u021bial\u0103 pentru a se asigura c\u0103 tubulatura men\u021bine echilibrul corect \u00eentre rezisten\u021ba mecanic\u0103 \u0219i flexibilitate. Tubulatura prea rigid\u0103 poate cre\u0219te riscul de rupere sau fracturi fragile, \u00een timp ce tubulatura prea moale poate duce la \u00eendoire, deteriorare \u0219i proceduri medicale poten\u021bial nesigure.<\/p>\n<p>The\u00a0<strong>Tester de rigiditate a acului medical<\/strong>\u00a0este proiectat pentru a simula condi\u021biile din lumea real\u0103 prin aplicarea unei for\u021be specificate \u00een centrul tubului \u0219i m\u0103surarea deform\u0103rii acestuia. Acest lucru asigur\u0103 c\u0103 tubulatura are rigiditatea necesar\u0103 pentru a func\u021biona \u00een siguran\u021b\u0103 \u00een aplica\u021bii medicale, cum ar fi injec\u021biile, perfuziile \u0219i alte proceduri critice.<\/p>\n<hr \/>\n<h2><strong>Aplica\u021bii<\/strong><\/h2>\n<p>Testerul de rigiditate a tubului de sering\u0103 TS-01 este utilizat pe scar\u0103 larg\u0103 \u00een\u00a0<strong>industria medical\u0103, farmaceutic\u0103 \u0219i a ambalajelor<\/strong>\u00a0unde controlul precis al caracteristicilor tubului este vital pentru siguran\u021ba produsului. Aplica\u021biile sale principale includ:<\/p>\n<ul>\n<li><strong>Fabricarea seringilor<\/strong>: Asigurarea faptului c\u0103 seringile, acele hipodermice \u0219i cateterele au nivelul necesar de rigiditate pentru a minimiza riscurile \u00een timpul inser\u021biei \u0219i oper\u0103rii.<\/li>\n<li><strong>Cercetare \u0219i dezvoltare \u00een domeniul dispozitivelor medicale<\/strong>: Testarea noilor modele \u0219i materiale utilizate \u00een tubulatura medical\u0103 pentru a respecta standardele interna\u021bionale de siguran\u021b\u0103, cum ar fi\u00a0<strong>ISO 9626<\/strong>.<\/li>\n<li><strong>Controlul calit\u0103\u021bii<\/strong>: Testarea de rutin\u0103 a materialelor de ambalare medicale, cum ar fi tuburile flexibile \u0219i locurile de injectare, pentru a se asigura c\u0103 acestea \u00eendeplinesc cerin\u021bele de reglementare \u0219i func\u021bioneaz\u0103 conform destina\u021biei \u00een timpul utiliz\u0103rii clinice.<\/li>\n<li><strong>Ambalaje medicale<\/strong>: Verificarea faptului c\u0103 tuburile utilizate \u00een ambalajele medicale nu sunt nici prea rigide (ceea ce le poate face casante), nici prea moi (ceea ce poate cauza probleme de flexibilitate \u00een timpul utiliz\u0103rii).<\/li>\n<li><strong>Industria farmaceutic\u0103<\/strong>: Asigurarea c\u0103 sistemul de administrare a medicamentelor este sigur \u0219i fiabil prin testarea tuburilor utilizate \u00een seringi \u0219i seturi de perfuzie.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Necesitate<\/strong><\/h2>\n<p>\u00cen industria medical\u0103,\u00a0<strong>rigiditatea tubului<\/strong>\u00a0nu este doar o caracteristic\u0103 de calitate - este o\u00a0<strong>factor critic de siguran\u021b\u0103<\/strong>. Rigiditatea unei seringi sau a unui ac hipodermic afecteaz\u0103 performan\u021ba sa general\u0103 \u0219i\u00a0<strong>rigiditate necorespunz\u0103toare<\/strong>\u00a0poate duce la diverse probleme opera\u021bionale, cum ar fi dificult\u0103\u021bi de inser\u021bie, rupere sau func\u021bionare defectuoas\u0103 \u00een timpul procedurilor medicale. Tubulatura care este prea rigid\u0103 poate deveni fragil\u0103 \u0219i poate ceda atunci c\u00e2nd este supus\u0103 stresului, duc\u00e2nd la o defec\u021biune catastrofal\u0103 \u00een timpul unei proceduri.<\/p>\n<p>\u00cen schimb, tubulatura prea flexibil\u0103 sau moale poate duce la \u00eendoire, \u00eendoire sau deformare, ceea ce poate provoca erori \u00een procedurile medicale sau chiar compromite sterilitatea. Testerul de rigiditate a tubului seringii ofer\u0103 un instrument esen\u021bial pentru\u00a0<strong>m\u0103sura\u021bi \u0219i verifica\u021bi<\/strong>\u00a0c\u0103 tubulatura utilizat\u0103 \u00een aceste dispozitive este optimizat\u0103 pentru siguran\u021b\u0103, flexibilitate \u0219i rezisten\u021b\u0103.<\/p>\n<hr \/>\n<h2><strong>Principiul de func\u021bionare<\/strong><\/h2>\n<p>TS-01\u00a0<strong>Tester de rigiditate a tubului seringii<\/strong>\u00a0func\u021bioneaz\u0103 pe baza unui principiu simplu, dar extrem de eficient. \u00cen timpul test\u0103rii, o for\u021b\u0103 specific\u0103 (p\u00e2n\u0103 la 60 N) este aplicat\u0103 \u00een centrul tubului, care este sus\u021binut la ambele capete. Testerul m\u0103soar\u0103\u00a0<strong>deviere<\/strong>\u00a0a tubului ca r\u0103spuns la aceast\u0103 for\u021b\u0103 aplicat\u0103.<\/p>\n<h4>Caracteristici principale:<\/h4>\n<ul>\n<li><strong>Aplicarea for\u021bei<\/strong>: Un piston \u00een form\u0103 de pan\u0103 contondent\u0103, \u00eenclinat la 60\u00b0 \u0219i cu o raz\u0103 cilindric\u0103 de 1 mm, aplic\u0103 o for\u021b\u0103 descendent\u0103 controlat\u0103 tubului.<\/li>\n<li><strong>M\u0103surarea devia\u021biei<\/strong>: Testerul m\u0103soar\u0103\u00a0<strong>deviere<\/strong>\u00a0a tubului cu o precizie de \u00b1 0,01 mm, ceea ce indic\u0103 rigiditatea materialului.<\/li>\n<li><strong>Gama de for\u021be<\/strong>: Dispozitivul este capabil s\u0103 testeze tuburile cu for\u021be cuprinse \u00eentre 1 N \u0219i 60 N, oferind o\u00a0<strong>gam\u0103 versatil\u0103<\/strong>\u00a0de m\u0103sur\u0103tori.<\/li>\n<\/ul>\n<p>Rezultatul acestui test se coreleaz\u0103 direct cu rigiditatea tubului \u0219i ajut\u0103 produc\u0103torii s\u0103 se asigure c\u0103 produsul se \u00eencadreaz\u0103 \u00een intervalul acceptabil pentru\u00a0<strong>siguran\u021b\u0103 \u0219i func\u021bionalitate<\/strong>\u00a0\u00een medii medicale.<\/p>\n<hr \/>\n<h2><strong>Specifica\u021bii tehnice<\/strong><\/h2>\n<p>Testerul de rigiditate a tubului de sering\u0103 TS-01 se m\u00e2ndre\u0219te cu o gam\u0103 de\u00a0<strong>caracteristici de \u00eenalt\u0103 precizie<\/strong>\u00a0care \u00eel fac un instrument indispensabil pentru testarea dispozitivelor medicale. Iat\u0103 specifica\u021biile cheie:<\/p>\n<ul>\n<li><strong>For\u021b\u0103 fix\u0103<\/strong>: 60 N (sau personalizabil)<\/li>\n<li><strong>Viteza de testare<\/strong>: Reglabil \u00eentre 1 \u0219i 500 mm\/min<\/li>\n<li><strong>Acurate\u021be<\/strong>: \u00b10,01 mm \u00een m\u0103surarea devia\u021biei<\/li>\n<li><strong>Surs\u0103 de alimentare<\/strong>: 110V p\u00e2n\u0103 la 220V AC<\/li>\n<li><strong>Sistemul de control<\/strong>: Controlat de PLC cu un\u00a0<strong>Ecran tactil HMI de 7 inchi<\/strong>\u00a0pentru u\u0219urin\u021ba de operare<\/li>\n<li><strong>Instala\u021bie de testare<\/strong>: Sunt disponibile mai multe dispozitive de fixare pentru teste de for\u021b\u0103 descendent\u0103<\/li>\n<li><strong>Protec\u021bie la suprasarcin\u0103<\/strong>: Protec\u021bie la suprasarcin\u0103 \u00eencorporat\u0103 pentru a preveni deteriorarea dispozitivului<\/li>\n<li><strong>Microimprimant\u0103<\/strong>: Pentru tip\u0103rirea imediat\u0103 a rezultatelor testelor<\/li>\n<\/ul>\n<p>Acestea\u00a0<strong>capacit\u0103\u021bi de \u00eenalt\u0103 precizie<\/strong>\u00a0asigur\u0103 m\u0103surarea precis\u0103 \u0219i fiabil\u0103 a rigidit\u0103\u021bii tubului seringii, oferind rezultate \u00een care produc\u0103torii \u0219i organismele de reglementare pot avea \u00eencredere.<\/p>\n<hr \/>\n<h2><strong>Avantaje<\/strong><\/h2>\n<p>Testerul de rigiditate pentru tuburi de sering\u0103 TS-01 ofer\u0103 mai multe avantaje fa\u021b\u0103 de metodele tradi\u021bionale de testare a rigidit\u0103\u021bii:<\/p>\n<ul>\n<li><strong>Precizie ridicat\u0103<\/strong>: The\u00a0<strong>\u00b10,01 mm<\/strong>\u00a0precizia \u00een m\u0103surarea deform\u0103rii asigur\u0103 rezultate extrem de fiabile pentru aplica\u021bii critice.<\/li>\n<li><strong>Gam\u0103 larg\u0103 de aplica\u021bii<\/strong>: Cu o for\u021b\u0103 reglabil\u0103 de p\u00e2n\u0103 la 60 N \u0219i viteze de testare variabile, TS-01 este adaptabil la diferite tipuri de tuburi \u0219i cerin\u021be de testare.<\/li>\n<li><strong>U\u0219urin\u021ba de utilizare<\/strong>: The\u00a0<strong>Sistem de control PLC<\/strong>\u00a0\u0219i\u00a0<strong>operare cu ecran tactil<\/strong>\u00a0simplific\u0103 procesul de testare, f\u0103c\u00e2ndu-l u\u0219or de utilizat chiar \u0219i pentru cei f\u0103r\u0103 cuno\u0219tin\u021be tehnice extinse.<\/li>\n<li><strong>Durabilitate<\/strong>: Cu protec\u021bie la suprasarcin\u0103 \u0219i revenire automat\u0103 dup\u0103 fiecare test, TS-01 asigur\u0103 longevitate \u0219i fiabilitate chiar \u0219i \u00een medii de testare cu volum mare.<\/li>\n<li><strong>Conformitatea cu standardele<\/strong>: Testerul este proiectat pentru a respecta\u00a0<strong>ISO 9626<\/strong>\u00a0\u0219i\u00a0<strong>GB\/T18457<\/strong>\u00a0asigur\u00e2ndu-se c\u0103 toate m\u0103sur\u0103torile respect\u0103 orient\u0103rile interna\u021bionale privind siguran\u021ba \u0219i performan\u021ba.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Configura\u021bii \u0219i accesorii<\/strong><\/h2>\n<p>The\u00a0<strong>TS-01 Tester de rigiditate a tubului de sering\u0103<\/strong>\u00a0vine cu mai multe configura\u021bii standard \u0219i accesorii op\u021bionale pentru a satisface diverse nevoi de testare:<\/p>\n<ul>\n<li><strong>Ma\u0219in\u0103 principal\u0103<\/strong>: Cuprinde o cruce mobil\u0103 \u0219i un piston de testare conectat la celula de sarcin\u0103.<\/li>\n<li><strong>Test Plunger<\/strong>: Pung\u0103 de precizie cu o pan\u0103 rotunjit\u0103 la v\u00e2rf, conceput\u0103 pentru a aplica for\u021ba specificat\u0103 pe tub.<\/li>\n<li><strong>Tigaie de testare<\/strong>: O tav\u0103 pentru a \u021bine tubulatura \u00een siguran\u021b\u0103 \u00een timpul test\u0103rii.<\/li>\n<li><strong>Cablu de alimentare \u0219i siguran\u021be<\/strong>: Esen\u021bial pentru func\u021bionare \u0219i siguran\u021b\u0103.<\/li>\n<\/ul>\n<p>Accesorii suplimentare, cum ar fi\u00a0<strong>corpuri personalizate<\/strong>\u00a0pentru diferite configura\u021bii de testare, pot fi ad\u0103ugate \u00een func\u021bie de tubulatura testat\u0103.<\/p>\n<hr \/>\n<h2><strong>Standarde<\/strong><\/h2>\n<p>The\u00a0<strong>TS-01 Tester de rigiditate a tubului de sering\u0103<\/strong>\u00a0este conceput pentru a satisface\u00a0<strong>standarde interna\u021bionale<\/strong>\u00a0pentru testarea dispozitivelor medicale, inclusiv:<\/p>\n<ul>\n<li><strong>ISO 9626<\/strong>: Define\u0219te propriet\u0103\u021bile mecanice necesare ale tuburilor din o\u021bel inoxidabil utilizate pentru fabricarea acelor. Standardul include metode de evaluare a rezisten\u021bei \u0219i durabilit\u0103\u021bii tuburilor de o\u021bel pentru a se asigura c\u0103 acestea \u00eendeplinesc cerin\u021bele produsului final. For\u021ba necesar\u0103 depinde de calibrul acului \u0219i de grosimea peretelui, doi factori care vor determina scopul acului. Testarea se realizeaz\u0103 folosind un ansamblu de \u00eendoire \u00een trei puncte pentru a determina rigiditatea materialului. \u00cen plus, se efectueaz\u0103 un test de \u00eendoire cantilever pentru a evalua capacitatea tubului de a rezista la fractur\u0103. Acest test este esen\u021bial pentru a se asigura c\u0103 acul poate rezista for\u021belor de forfecare care pot fi \u00eent\u00e2lnite \u00eentr-un mediu clinic.<\/li>\n<li><strong>GB\/T18457<\/strong>: Standarde na\u021bionale chineze pentru testarea dispozitivelor medicale, inclusiv seringi \u0219i tuburi.<\/li>\n<\/ul>\n<p>Aceste standarde asigur\u0103 conformitatea testerului TS-01 cu cerin\u021bele de siguran\u021b\u0103, calitate \u0219i performan\u021b\u0103 recunoscute la nivel global, f\u0103c\u00e2ndu-l ideal pentru utilizarea \u00een medii reglementate.<\/p>\n<hr \/>\n<h2><strong>Asisten\u021b\u0103 \u0219i formare<\/strong><\/h2>\n<p><a href=\"https:\/\/www.materialstests.com\/ro\/\"><strong>Cell Instruments<\/strong><\/a>\u00a0oferte\u00a0<strong>sprijin cuprinz\u0103tor<\/strong>\u00a0pentru\u00a0<strong>TS-01 Tester de rigiditate a tubului de sering\u0103<\/strong>, inclusiv:<\/p>\n<ul>\n<li><strong>Asisten\u021b\u0103 tehnic\u0103<\/strong>: Acces la asisten\u021b\u0103 de specialitate pentru depanare \u0219i calibrare.<\/li>\n<li><strong>Formare profesional\u0103<\/strong>: Formare la fa\u021ba locului sau online pentru personal cu privire la modul de utilizare a aparatului \u0219i de interpretare a rezultatelor testelor.<\/li>\n<li><strong>Actualiz\u0103ri software<\/strong>: Actualiz\u0103ri regulate ale software-ului ma\u0219inii pentru a \u00eembun\u0103t\u0103\u021bi func\u021bionalitatea \u0219i a asigura conformitatea cu standardele \u00een schimbare din industrie.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Overview The\u00a0Syringe Tube Stiffness Tester\u00a0(TS-01)\u00a0is a high-precision testing device designed to measure the stiffness of medical tubing, particularly hypodermic needles and syringes. As\u00a0stiffness\u00a0directly impacts the safety, flexibility, and overall performance of medical tubing, accurate\u00a0stiffness testing\u00a0is essential to ensure that tubing maintains the right balance of mechanical strength and flexibility. Overly stiff tubing can increase the [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[],"class_list":["post-2774","products","type-products","status-publish","hentry","products-categories-medical-device-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products\/2774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products\/2774\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/media?parent=2774"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/products-categories?post=2774"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/ro\/wp-json\/wp\/v2\/productstags?post=2774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}