{"id":2835,"date":"2026-02-05T01:34:54","date_gmt":"2026-02-05T01:34:54","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/rdvt-01-vacutainer-drawing-volume-tester\/"},"modified":"2026-02-05T01:34:54","modified_gmt":"2026-02-05T01:34:54","slug":"rdvt-01-vacutainer-drawing-volume-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/pl\/products\/rdvt-01-vacutainer-drawing-volume-tester.html","title":{"rendered":"RDVT-01 Tester obj\u0119to\u015bci pobranej z Vacutainera"},"content":{"rendered":"<div>\n<h2><strong>1.Introduction of\u00a0RDVT-01 Drawing\u00a0<a class=\"aahaf6o\" title=\"tester g\u0142o\u015bno\u015bci\" href=\"https:\/\/www.materialstests.com\/pl\/products\/clrt-01-carbon-dioxide-volume-tester.html\/\">tester g\u0142o\u015bno\u015bci<\/a><\/strong><\/h2>\n<\/div>\n<p>RDVT-01 Drawing Volume Tester applies to the pumping volume of vacutainers (blood collection tubes) and it can accurately simulate a certain altitude and create a real environment for analysis of vacutainer performance.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>2.Why do you need a RDVT-01 Drawing Volume Tester?<\/strong><\/h2>\n<p>Using vacutainers (blood collection tubes) in high-altitude areas can present some challenges due to the changes in atmospheric pressure and partial pressure of gases at higher elevations.<\/p>\n<p>At higher altitudes, the atmospheric pressure decreases. This can affect the filling of vacutainers, particularly those that rely on pressure differences to draw blood into the tube. The lower atmospheric pressure might result in slower or incomplete blood collection.<\/p>\n<p>Changes in atmospheric pressure can affect the partial pressure of gases in the blood, leading to altered blood composition. This can impact tests that are sensitive to variations in blood gases.<\/p>\n<p>Manufacturers may subject their vacutainers to pressure testing to simulate conditions at different altitudes. This helps assess the impact of reduced atmospheric pressure on the blood collection process.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium wp-image-282\" src=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-300x300.jpg\" alt=\"RDVT-01 Tester obj\u0119to\u015bci pobranej z Vacutainera\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-300x300.jpg 300w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-150x150.jpg 150w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-768x768.jpg 768w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-600x600.jpg 600w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester-100x100.jpg 100w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2><strong>3.Advantages of RDVT-01 Drawing Volume Tester<\/strong><\/h2>\n<p>1.RDVT-01 is equipped with a Programmable Logic Controller (PLC) for stable industrial-level control and\u00a0a user-friendly Human-Machine Interface (HMI) touch screen for convenient operation.<\/p>\n<p>2.It\u00a0offers a convenient digital input and automatically maintains a consistent pressure level within the tank, adjusting as the liquid level changes. This feature ensures the precision and accuracy of the testing process.<\/p>\n<p>3.The system includes an integrated vacuum pump, effectively saving both space and additional costs for the user. This\u00a0compact\u00a0design enhances user convenience and efficiency during operation.<\/p>\n<h3><\/h3>\n<h2><strong>4.Test\u00a0Principle of RDVT-01 Drawing Volume Tester<\/strong><\/h2>\n<p>Insert the test vacutainer\u00a0into the puncture site of the test system to make it consistent with the pressure inside the vacuum tank; then make it form different pressure values inside according to the altitude of the area where the vacutainer\u00a0is used.<\/p>\n<p>Wait for 1 minute. Then measure the weight change between the empty vacutainer and the one after it\u2019s filled. \u00a0The difference is regarded as the drawing volume.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>5.Zastosowanie:\u00a0<\/strong><\/h2>\n<p>Vacutainer, blood collection tube.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-283\" src=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-300x300.jpg\" alt=\"RDVT-01 Tester obj\u0119to\u015bci pobranej z Vacutainera\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-300x300.jpg 300w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-150x150.jpg 150w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-768x768.jpg 768w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-600x600.jpg 600w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2-100x100.jpg 100w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/RDVT-01-Vacutainer-Drawing-Volume-Tester2.jpg 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2><strong>6.Specyfikacja<\/strong><\/h2>\n<div class=\"table\">\n<table>\n<tbody>\n<tr>\n<td>Vacuum Range<\/td>\n<td>0~-45 Kpa<\/p>\n<p>(Similar to altitude 5000m)<\/td>\n<\/tr>\n<tr>\n<td>Dok\u0142adno\u015b\u0107<\/td>\n<td>0.1 Kpa<\/td>\n<\/tr>\n<tr>\n<td>Kontrola<\/td>\n<td>PLC i interfejs cz\u0142owiek-maszyna<\/td>\n<\/tr>\n<tr>\n<td>Moc<\/td>\n<td>AC 110~220V 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<h2><strong>7.Standardy:<\/strong><\/h2>\n<p>YY 0314, EN 14820, ISO 6710<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>8.Konfiguracja:<\/strong><\/h2>\n<p>a)Standard configuration: RDVT-01 Drawing Volume Tester, vacuum tank, sample holder, fuses, manual, calibration certificate, power cord.<\/p>\n<p>b)Optional configuration: Non-Standard chamber, RS 232 Port, COM Line, Software<\/p>\n<p>&nbsp;<\/p>\n<p class=\"aahaf6o\">Je\u015bli chcesz uzyska\u0107 wi\u0119cej informacji na temat tego produktu, skontaktuj si\u0119 z nami. Polecamy r\u00f3wnie\u017c inne popularne produkty:\u00a0<a class=\"aahaf6o\" title=\"wykres testowania obj\u0119to\u015bci gazu w\u0119glowego\" href=\"https:\/\/www.materialstests.com\/pl\/products\/clrt-01-carbon-dioxide-volume-tester.html\/\">wykres testowania obj\u0119to\u015bci gazu w\u0119glowego<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>1. wprowadzenie testera obj\u0119to\u015bci pobierania RDVT-01 Tester obj\u0119to\u015bci pobierania RDVT-01 ma zastosowanie do obj\u0119to\u015bci pompowania wakuometr\u00f3w (rurek do pobierania krwi) i mo\u017ce dok\u0142adnie symulowa\u0107 okre\u015blon\u0105 wysoko\u015b\u0107 i stworzy\u0107 rzeczywiste \u015brodowisko do analizy wydajno\u015bci wakuometru.   2.Dlaczego potrzebny jest tester obj\u0119to\u015bci pobierania RDVT-01? U\u017cywanie wakuometr\u00f3w (prob\u00f3wek do pobierania krwi) na du\u017cych wysoko\u015bciach mo\u017ce [...]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[1439,1440,1441],"class_list":["post-2835","products","type-products","status-publish","hentry","products-categories-medical-device-tester","productstags-carbonic-gas-volume-testing-chart","productstags-co2-gas-volume-tester","productstags-gas-volume-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/pl\/wp-json\/wp\/v2\/products\/2835","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/pl\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/pl\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/pl\/wp-json\/wp\/v2\/products\/2835\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/pl\/wp-json\/wp\/v2\/media?parent=2835"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/pl\/wp-json\/wp\/v2\/products-categories?post=2835"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/pl\/wp-json\/wp\/v2\/productstags?post=2835"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}