{"id":2774,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/ts-01-syringe-tube-stiffness-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"ts-01-syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/lv\/products\/ts-01-syringe-tube-stiffness-tester.html","title":{"rendered":"TS-01 \u0161\u013circes caurul\u012btes stinguma testeris"},"content":{"rendered":"<h2><strong>P\u0101rskats<\/strong><\/h2>\n<p>Port\u0101ls\u00a0<strong><a href=\"https:\/\/www.materialstests.com\/lv\/medical-device-tester.html\/\">\u0160\u013circes caurules stingr\u012bbas test\u0113t\u0101js<\/a>\u00a0(TS-01)<\/strong>\u00a0ir augstas precizit\u0101tes test\u0113\u0161anas ier\u012bce, kas paredz\u0113ta medic\u012bnisko cauru\u013cu, jo \u012bpa\u0161i injekciju adatu un \u0161\u013cir\u010du, stingr\u012bbas m\u0113r\u012b\u0161anai. K\u0101\u00a0<strong>stingr\u012bba<\/strong>\u00a0tie\u0161i ietekm\u0113 medic\u012bnisko cauru\u013cu dro\u0161\u012bbu, elast\u012bgumu un kop\u0113jo darb\u012bbas efektivit\u0101ti, prec\u012bzi\u00a0<strong>stingr\u012bbas p\u0101rbaude<\/strong>\u00a0Ir \u013coti svar\u012bgi nodro\u0161in\u0101t, lai caurul\u0113m b\u016btu pareizais meh\u0101nisk\u0101s iztur\u012bbas un elast\u012bbas l\u012bdzsvars. P\u0101r\u0101k cietas caurules var palielin\u0101t l\u016bzumu vai trauslu l\u016bzumu risku, savuk\u0101rt p\u0101r\u0101k m\u012bkstas caurules var izrais\u012bt salie\u0161anu, boj\u0101jumus un potenci\u0101li nedro\u0161as medic\u012bnisk\u0101s proced\u016bras.<\/p>\n<p>Port\u0101ls\u00a0<strong>Medic\u012bnisk\u0101 adatu stingr\u012bbas test\u0113t\u0101js<\/strong>\u00a0ir izstr\u0101d\u0101ts, lai simul\u0113tu re\u0101los apst\u0101k\u013cus, pieliekot noteiktu sp\u0113ku caurules vidusda\u013cai un m\u0113rot t\u0101s deform\u0101ciju. Tas nodro\u0161ina, ka caurulei ir nepiecie\u0161am\u0101 stingr\u012bba, lai t\u0101 dro\u0161i darbotos medic\u012bnisk\u0101s lieto\u0161anas gad\u012bjumos, piem\u0113ram, injekcij\u0101s, inf\u016bzij\u0101s un cit\u0101s kritisk\u0101s proced\u016br\u0101s.<\/p>\n<hr \/>\n<h2><strong>Pieteikumi<\/strong><\/h2>\n<p>\u0160\u013circes caurules stingr\u012bbas test\u0113t\u0101ju TS-01 pla\u0161i izmanto\u00a0<strong>medic\u012bnas, farm\u0101cijas un iepakojuma nozares<\/strong>\u00a0kur prec\u012bza cauru\u013cvadu \u012bpa\u0161\u012bbu kontrole ir b\u016btiska produkta dro\u0161\u012bbai. Galvenie pielietojuma veidi ir \u0161\u0101di:<\/p>\n<ul>\n<li><strong>\u0160\u013cir\u010du ra\u017eo\u0161ana<\/strong>: Nodro\u0161in\u0101t, lai \u0161\u013circes, injekciju adatas un katetriem b\u016btu nepiecie\u0161amais stingr\u012bbas l\u012bmenis, lai l\u012bdz minimumam samazin\u0101tu risku to ievad\u012b\u0161anas un lieto\u0161anas laik\u0101.<\/li>\n<li><strong>Medic\u012bnisko ier\u012b\u010du p\u0113tniec\u012bba un att\u012bst\u012bba<\/strong>: Jauno medic\u012bnisko cauru\u013cu konstrukciju un materi\u0101lu test\u0113\u0161ana, lai nodro\u0161in\u0101tu atbilst\u012bbu starptautiskajiem dro\u0161\u012bbas standartiem, piem\u0113ram,\u00a0<strong>ISO 9626<\/strong>.<\/li>\n<li><strong>Kvalit\u0101tes kontrole<\/strong>: Medic\u012bnisko iepakojuma materi\u0101lu, piem\u0113ram, elast\u012bgo caurul\u012b\u0161u un injekciju vietu, regul\u0101ra p\u0101rbaude, lai nodro\u0161in\u0101tu to atbilst\u012bbu normat\u012bvaj\u0101m pras\u012bb\u0101m un paredz\u0113to funkcionalit\u0101ti kl\u012bniskaj\u0101 lieto\u0161an\u0101.<\/li>\n<li><strong>Medic\u012bnas iepakojums<\/strong>: P\u0101rbaud\u012bt, vai medic\u012bniskaj\u0101 iepakojum\u0101 izmantot\u0101s caurules nav ne p\u0101r\u0101k cietas (kas var padar\u012bt t\u0101s trauslas), ne p\u0101r\u0101k m\u012bkstas (kas var rad\u012bt probl\u0113mas ar elast\u012bbu lieto\u0161anas laik\u0101).<\/li>\n<li><strong>Farmaceitisk\u0101 r\u016bpniec\u012bba<\/strong>: Nodro\u0161in\u0101t z\u0101\u013cu pieg\u0101des sist\u0113mas dro\u0161\u012bbu un uzticam\u012bbu, p\u0101rbaudot \u0161\u013circes un inf\u016bzijas komplektos izmantot\u0101s caurules.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Nepiecie\u0161am\u012bba<\/strong><\/h2>\n<p>Medic\u012bnas nozar\u0113,\u00a0<strong>caurules stingr\u012bba<\/strong>\u00a0nav tikai kvalit\u0101tes paz\u012bme \u2014 t\u0101 ir\u00a0<strong>kritiskais dro\u0161\u012bbas koeficients<\/strong>. \u0160\u013circes vai injekcijas adatas stingr\u012bba ietekm\u0113 t\u0101s kop\u0113jo darb\u012bbu, un\u00a0<strong>neatbilsto\u0161a stingr\u012bba<\/strong>\u00a0tas var izrais\u012bt da\u017e\u0101das darb\u012bbas probl\u0113mas, piem\u0113ram, ievad\u012b\u0161anas gr\u016bt\u012bbas, pl\u012bsumus vai darb\u012bbas trauc\u0113jumus medic\u012bnisko proced\u016bru laik\u0101. P\u0101r\u0101k cieta caurule var k\u013c\u016bt trausla un sapl\u012bst, ja tiek pak\u013cauta slodzei, kas proced\u016bras laik\u0101 var izrais\u012bt katastrof\u0101lu boj\u0101jumu.<\/p>\n<p>Savuk\u0101rt p\u0101r\u0101k elast\u012bgas vai m\u012bkstas caurules var saliekties, sav\u012bties vai deform\u0113ties, kas savuk\u0101rt var izrais\u012bt k\u013c\u016bdas medic\u012bniskaj\u0101s proced\u016br\u0101s vai pat apdraud\u0113t sterilit\u0101ti. \u0160\u013circes caurules stingr\u012bbas test\u0113t\u0101js ir b\u016btisks instruments, lai\u00a0<strong>izm\u0113r\u012bt un p\u0101rbaud\u012bt<\/strong>\u00a0ka \u0161aj\u0101s ier\u012bc\u0113s izmantot\u0101s caurules ir optimiz\u0113tas, lai nodro\u0161in\u0101tu dro\u0161\u012bbu, elast\u012bbu un iztur\u012bbu.<\/p>\n<hr \/>\n<h2><strong>Darba princips<\/strong><\/h2>\n<p>TS-01\u00a0<strong>\u0160\u013circes caurules stingr\u012bbas test\u0113t\u0101js<\/strong>\u00a0darbojas p\u0113c vienk\u0101r\u0161a, bet \u013coti efekt\u012bva principa. Test\u0113\u0161anas laik\u0101 caurules vid\u016b, kas ir nostiprin\u0101ta abos galos, tiek pielikts noteikts sp\u0113ks (l\u012bdz 60 N). Test\u0113t\u0101js m\u0113ra\u00a0<strong>novirze<\/strong>\u00a0caurules deform\u0101cija, rea\u0123\u0113jot uz \u0161o pielikto sp\u0113ku.<\/p>\n<h4>Galven\u0101s funkcijas:<\/h4>\n<ul>\n<li><strong>Sp\u0113ka pielietojums<\/strong>: Uz caurules tiek pielikts kontrol\u0113ts sp\u0113ks uz leju, izmantojot strupu, 60\u00b0 le\u0146\u0137\u012b novietotu, \u0137\u012b\u013cveida virzuli ar cilindrisko r\u0101diusu 1 mm.<\/li>\n<li><strong>Lieces m\u0113r\u012b\u0161ana<\/strong>: Test\u0113t\u0101js m\u0113ra\u00a0<strong>novirze<\/strong>\u00a0caurules diametru ar precizit\u0101ti \u00b10,01 mm, kas liecina par materi\u0101la stingr\u012bbu.<\/li>\n<li><strong>Sp\u0113ka diapazons<\/strong>: Ier\u012bce sp\u0113j p\u0101rbaud\u012bt caurules, pielietojot sp\u0113ku no 1 N l\u012bdz 60 N, nodro\u0161inot\u00a0<strong>pla\u0161s sortiments<\/strong>\u00a0m\u0113r\u012bjumu.<\/li>\n<\/ul>\n<p>\u0160\u012b testa rezult\u0101ts ir tie\u0161i saist\u012bts ar cauru\u013cvadu stingr\u012bbu un pal\u012bdz ra\u017eot\u0101jiem nodro\u0161in\u0101t, ka produkts atbilst pie\u013caujamajam diapazonam\u00a0<strong>dro\u0161\u012bba un funkcionalit\u0101te<\/strong>\u00a0medic\u012bniskaj\u0101 vid\u0113.<\/p>\n<hr \/>\n<h2><strong>Tehnisk\u0101s specifik\u0101cijas<\/strong><\/h2>\n<p>TS-01 \u0161\u013circes caurules stingr\u012bbas test\u0113t\u0101jam ir pla\u0161s\u00a0<strong>augstas precizit\u0101tes funkcijas<\/strong>\u00a0kas padara to par neaizst\u0101jamu r\u012bku medic\u012bnisko ier\u012b\u010du test\u0113\u0161anai. \u0160eit ir galvenie tehniskie parametri:<\/p>\n<ul>\n<li><strong>Fiks\u0113ta sp\u0113ka<\/strong>: 60 N (vai p\u0113c izv\u0113les)<\/li>\n<li><strong>Testa \u0101trums<\/strong>: Regul\u0113jams diapazon\u0101 no 1 l\u012bdz 500 mm\/min<\/li>\n<li><strong>Precizit\u0101te<\/strong>: \u00b10,01 mm novirzes m\u0113r\u012bjumos<\/li>\n<li><strong>Baro\u0161anas avots<\/strong>: 110 V l\u012bdz 220 V mai\u0146str\u0101va<\/li>\n<li><strong>Vad\u012bbas sist\u0113ma<\/strong>: ar PLC vad\u012bbu un\u00a0<strong>7 collu HMI sk\u0101rienekr\u0101ns<\/strong>\u00a0lieto\u0161anas \u0113rt\u012bbas labad<\/li>\n<li><strong>Test\u0113\u0161anas iek\u0101rta<\/strong>: Pieejami da\u017e\u0101di stiprin\u0101jumi sp\u0113ka pielik\u0161anas testiem<\/li>\n<li><strong>Aizsardz\u012bba pret p\u0101rslodzi<\/strong>: Ieb\u016bv\u0113ta p\u0101rslodzes aizsardz\u012bba, lai nov\u0113rstu ier\u012bces boj\u0101jumus<\/li>\n<li><strong>Mikroprinteris<\/strong>: Lai nekav\u0113joties izdruk\u0101tu testa rezult\u0101tus<\/li>\n<\/ul>\n<p>\u0160ie\u00a0<strong>augstas precizit\u0101tes iesp\u0113jas<\/strong>\u00a0nodro\u0161in\u0101t, ka \u0161\u013circes caurules stingr\u012bba tiek m\u0113r\u012bta prec\u012bzi un uzticami, sniedzot rezult\u0101tus, kuriem var uztic\u0113ties gan ra\u017eot\u0101ji, gan regulat\u012bv\u0101s iest\u0101des.<\/p>\n<hr \/>\n<h2><strong>Priek\u0161roc\u012bbas<\/strong><\/h2>\n<p>TS-01 \u0161\u013circes caurules stingr\u012bbas test\u0113t\u0101jam ir vair\u0101kas priek\u0161roc\u012bbas sal\u012bdzin\u0101jum\u0101 ar tradicion\u0101laj\u0101m stingr\u012bbas p\u0101rbaudes metod\u0113m:<\/p>\n<ul>\n<li><strong>Augsta precizit\u0101te<\/strong>:\u00a0<strong>\u00b10,01 mm<\/strong>\u00a0Precizit\u0101te lieces m\u0113r\u012bjumos nodro\u0161ina \u013coti uzticamus rezult\u0101tus kritisk\u0101s lietojumprogramm\u0101s.<\/li>\n<li><strong>Pla\u0161s pielietojuma spektrs<\/strong>: Pateicoties regul\u0113jamai sp\u0113kam l\u012bdz 60 N un main\u012bgam p\u0101rbaudes \u0101trumam, TS-01 ir piem\u0113rots da\u017e\u0101da veida caurul\u0113m un da\u017e\u0101d\u0101m p\u0101rbaudes pras\u012bb\u0101m.<\/li>\n<li><strong>Lieto\u0161anas \u0113rtums<\/strong>:\u00a0<strong>PLC vad\u012bbas sist\u0113ma<\/strong>\u00a0un\u00a0<strong>darb\u012bba ar sk\u0101rienj\u016bt\u012bgo ekr\u0101nu<\/strong>\u00a0vienk\u0101r\u0161ot test\u0113\u0161anas procesu, padarot to \u0113rti lietojamu pat tiem, kuriem nav pla\u0161u tehnisko zin\u0101\u0161anu.<\/li>\n<li><strong>Iztur\u012bba<\/strong>: Pateicoties p\u0101rslodzes aizsardz\u012bbai un autom\u0101tiskai atgrie\u0161anai s\u0101kuma st\u0101vokl\u012b p\u0113c katra testa, TS-01 nodro\u0161ina ilgu kalpo\u0161anas laiku un uzticam\u012bbu pat intens\u012bv\u0101s test\u0113\u0161anas apst\u0101k\u013cos.<\/li>\n<li><strong>Atbilst\u012bba standartiem<\/strong>: Test\u0113t\u0101js ir izstr\u0101d\u0101ts atbilsto\u0161i\u00a0<strong>ISO 9626<\/strong>\u00a0un\u00a0<strong>GB\/T 18457<\/strong>\u00a0standartus, nodro\u0161inot, ka visi m\u0113r\u012bjumi atbilst starptautiskaj\u0101m dro\u0161\u012bbas un veiktsp\u0113jas vadl\u012bnij\u0101m.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Konfigur\u0101cijas un piederumi<\/strong><\/h2>\n<p>Port\u0101ls\u00a0<strong>TS-01 \u0161\u013circes caurul\u012btes stinguma testeris<\/strong>\u00a0ir pieejams vair\u0101k\u0101s standarta konfigur\u0101cij\u0101s un ar papildu piederumiem, lai apmierin\u0101tu da\u017e\u0101das test\u0113\u0161anas vajadz\u012bbas:<\/p>\n<ul>\n<li><strong>Galven\u0101 ma\u0161\u012bna<\/strong>: Sast\u0101v no p\u0101rvietojama \u0161\u0137\u0113rssviras un testa virzuli, kas savienots ar slodzes dev\u0113ju.<\/li>\n<li><strong>P\u0101rbaudes virzulis<\/strong>: Prec\u012bzs virzulis ar noapa\u013cotu \u0137\u012bli gal\u0101, kas paredz\u0113ts, lai uz cauruli iedarbotos ar noteiktu sp\u0113ku.<\/li>\n<li><strong>Testa pannas<\/strong>: Pannas, kas test\u0113\u0161anas laik\u0101 dro\u0161i notur caurules.<\/li>\n<li><strong>Str\u0101vas vads un dro\u0161in\u0101t\u0101js<\/strong>: Neaizst\u0101jams darb\u012bbai un dro\u0161\u012bbai.<\/li>\n<\/ul>\n<p>Papildu piederumi, piem\u0113ram,\u00a0<strong>p\u0113c pas\u016bt\u012bjuma izgatavoti apr\u012bkojuma elementi<\/strong>\u00a0atkar\u012bb\u0101 no test\u0113jamaj\u0101m caurul\u0113m var pievienot da\u017e\u0101das testa konfigur\u0101cijas.<\/p>\n<hr \/>\n<h2><strong>Standarti<\/strong><\/h2>\n<p>Port\u0101ls\u00a0<strong>TS-01 \u0161\u013circes caurul\u012btes stinguma testeris<\/strong>\u00a0ir paredz\u0113ts, lai atbilstu\u00a0<strong>starptautiskie standarti<\/strong>\u00a0medic\u012bnisko ier\u012b\u010du test\u0113\u0161anai, tostarp:<\/p>\n<ul>\n<li><strong>ISO 9626<\/strong>: Nosaka nepiecie\u0161am\u0101s meh\u0101nisk\u0101s \u012bpa\u0161\u012bbas ner\u016bs\u0113jo\u0161\u0101 t\u0113rauda caurul\u0113m, ko izmanto adatu ra\u017eo\u0161an\u0101. Standarts ietver metodes t\u0113rauda cauru\u013cu iztur\u012bbas un ilgm\u016b\u017e\u012bbas nov\u0113rt\u0113\u0161anai, lai nodro\u0161in\u0101tu to atbilst\u012bbu galaprodukta pras\u012bb\u0101m. Nepiecie\u0161amais sp\u0113ks ir atkar\u012bgs no adatas diametra un sienas biezuma \u2014 diviem faktoriem, kas nosaka adatas lieto\u0161anas m\u0113r\u0137i. Test\u0113\u0161ana tiek veikta, izmantojot tr\u012bspunktu lieces iek\u0101rtu, lai noteiktu materi\u0101la stingr\u012bbu. Turkl\u0101t tiek veikts konsoles lieces tests, lai nov\u0113rt\u0113tu caurules iztur\u012bbu pret l\u016bzumiem. \u0160is tests ir \u013coti svar\u012bgs, lai nodro\u0161in\u0101tu, ka adata var iztur\u0113t \u0161\u0137\u0113res sp\u0113kus, kas var rasties kl\u012bnisk\u0101 vid\u0113.<\/li>\n<li><strong>GB\/T 18457<\/strong>: \u0136\u012bnas valsts standarti medic\u012bnisko ier\u012b\u010du, tostarp \u0161\u013cir\u010du un cauru\u013cu, test\u0113\u0161anai.<\/li>\n<\/ul>\n<p>\u0160ie standarti garant\u0113, ka test\u0113t\u0101js TS-01 atbilst visp\u0101r\u0113ji atz\u012btaj\u0101m dro\u0161\u012bbas, kvalit\u0101tes un veiktsp\u0113jas pras\u012bb\u0101m, t\u0101d\u0113j\u0101di padarot to ide\u0101li piem\u0113rotu lieto\u0161anai regul\u0113t\u0101s vid\u0113s.<\/p>\n<hr \/>\n<h2><strong>Atbalsts un apm\u0101c\u012bba<\/strong><\/h2>\n<p><a href=\"https:\/\/www.materialstests.com\/lv\/\"><strong>Cell Instruments<\/strong><\/a>\u00a0pied\u0101v\u0101jumi\u00a0<strong>visaptvero\u0161s atbalsts<\/strong>\u00a0par\u00a0<strong>TS-01 \u0161\u013circes caurul\u012btes stinguma testeris<\/strong>, tostarp:<\/p>\n<ul>\n<li><strong>Tehniskais atbalsts<\/strong>: Piek\u013cuve ekspertu pal\u012bdz\u012bbai probl\u0113mu nov\u0113r\u0161an\u0101 un kalibr\u0113\u0161an\u0101.<\/li>\n<li><strong>Apm\u0101c\u012bba<\/strong>: Person\u0101la apm\u0101c\u012bba uz vietas vai tie\u0161saist\u0113 par to, k\u0101 r\u012bkoties ar iek\u0101rtu un interpret\u0113t testa rezult\u0101tus.<\/li>\n<li><strong>Programmat\u016bras atjaunin\u0101jumi<\/strong>: Regul\u0101ri iek\u0101rtas programmat\u016bras atjaunin\u0101jumi, lai uzlabotu funkcionalit\u0101ti un nodro\u0161in\u0101tu atbilst\u012bbu main\u012bgajiem nozares standartiem.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Overview The\u00a0Syringe Tube Stiffness Tester\u00a0(TS-01)\u00a0is a high-precision testing device designed to measure the stiffness of medical tubing, particularly hypodermic needles and syringes. As\u00a0stiffness\u00a0directly impacts the safety, flexibility, and overall performance of medical tubing, accurate\u00a0stiffness testing\u00a0is essential to ensure that tubing maintains the right balance of mechanical strength and flexibility. Overly stiff tubing can increase the [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[],"standard-category":[],"class_list":["post-2774","products","type-products","status-publish","hentry","products-categories-medical-device-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/products\/2774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/products\/2774\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/media?parent=2774"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/products-categories?post=2774"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/productstags?post=2774"},{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/standard-category?post=2774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}