{"id":663,"date":"2025-12-11T06:43:59","date_gmt":"2025-12-11T06:43:59","guid":{"rendered":"https:\/\/www.materialstests.com\/?p=663"},"modified":"2025-12-11T06:44:03","modified_gmt":"2025-12-11T06:44:03","slug":"elastomeric-closures-penetrability-test-medical-packaging-safety","status":"publish","type":"post","link":"https:\/\/www.materialstests.com\/lv\/news\/elastomeric-closures-penetrability-test-medical-packaging-safety.html","title":{"rendered":"Elastom\u0113ru aizdares caurlaid\u012bbas tests: Medic\u012bnisk\u0101 iepakojuma dro\u0161uma atsl\u0113ga"},"content":{"rendered":"<p>Elastom\u0113ru aizv\u0101kojumus parasti izmanto farmaceitiskaj\u0101 un medic\u012bniskaj\u0101 iepakojum\u0101, lai aiztais\u012btu injekciju flakonus, \u0161\u013circes un citus traukus. \u0160iem aizv\u0101kojumiem ir iz\u0161\u0137iro\u0161a noz\u012bme iepakot\u0101 satura sterilit\u0101tes un dro\u0161\u012bbas saglab\u0101\u0161an\u0101. Lai nodro\u0161in\u0101tu to efektivit\u0101ti, ir nepiecie\u0161ams&nbsp;<strong>elastom\u0113ra aizdares caurlaid\u012bbas tests<\/strong>&nbsp;tiek veikta, lai nov\u0113rt\u0113tu aizdares iztur\u012bbu pret caurdur\u0161anu. \u0160aj\u0101 rakst\u0101 ir apl\u016bkota caurlaid\u012bbas testa noz\u012bme, testa proced\u016bra un tas, k\u0101 ar t\u0101diem r\u012bkiem k\u0101, piem.&nbsp;<strong>NPT-01 Adatu punkcijas testeris<\/strong>&nbsp;pal\u012bdz\u0113t nodro\u0161in\u0101t atbilst\u012bbu standartiem, piem\u0113ram.&nbsp;<strong>USP 381<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">K\u0101p\u0113c elastom\u0113ra sl\u0113gpl\u0101k\u0161\u0146u herm\u0113tiskuma test\u0113\u0161ana ir b\u016btiska<\/h2>\n\n\n\n<p>Elastom\u0113ru aizb\u0101\u017e\u0146u caurlaid\u012bba ir \u013coti svar\u012bga, lai saglab\u0101tu farmaceitisko produktu dro\u0161umu un efektivit\u0101ti. L\u016bk, k\u0101p\u0113c \u0161is tests ir \u013coti svar\u012bgs:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Nodro\u0161ina bl\u012bv\u0113juma integrit\u0101ti<\/strong>: Elastom\u0113ru aizdares galvenais m\u0113r\u0137is ir saglab\u0101t dro\u0161u bl\u012bv\u0113jumu. Uzglab\u0101\u0161anas vai lieto\u0161anas laik\u0101 aizv\u0101kojumiem j\u0101b\u016bt iztur\u012bgiem pret caurdur\u0161anu, lai nodro\u0161in\u0101tu satura integrit\u0101ti. \u0160\u012bs funkcijas neizpilde var izrais\u012bt pies\u0101r\u0146ojumu vai sterilit\u0101tes zudumu.<\/li>\n\n\n\n<li><strong>Nov\u0113r\u0161 pies\u0101r\u0146ojumu<\/strong>: Medic\u012bn\u0101, jo \u012bpa\u0161i injic\u0113jamos produktos, izmantotajiem aizv\u0101kojumiem ir j\u0101b\u016bt iztur\u012bgiem pret adatu un citu asu priek\u0161metu iespie\u0161anu. .\u00a0<strong>elastom\u0113ra aizdares caurlaid\u012bbas tests<\/strong>\u00a0nodro\u0161ina, ka aizvars sp\u0113j iztur\u0113t \u0161\u0101dus caurdurtus caurumus, nepie\u013caujot pies\u0101r\u0146ojuma iek\u013c\u016b\u0161anu.<\/li>\n\n\n\n<li><strong>Ties\u012bbu aktu atbilst\u012bba<\/strong>: Regulat\u012bv\u0101s iest\u0101des, piem\u0113ram, FDA un USP, pieprasa, lai elastom\u0113ra aizdares iztur\u0113tu noteiktus iztur\u012bbas un caurdur\u0161anas testus. \u0160ie noteikumi ir \u013coti svar\u012bgi, lai nodro\u0161in\u0101tu injic\u0113jamo z\u0101\u013cu un citu medic\u012bnas produktu dro\u0161\u012bbu.<\/li>\n\n\n\n<li><strong>Kvalit\u0101tes kontrole<\/strong>: Ra\u017eot\u0101ji izmanto caurlaid\u012bbas testu k\u0101 da\u013cu no kvalit\u0101tes kontroles procesa, lai p\u0101rliecin\u0101tos, ka aizv\u0101kojumi norm\u0101los lieto\u0161anas apst\u0101k\u013cos darbojas, k\u0101 paredz\u0113ts. Tas ir \u012bpa\u0161i svar\u012bgi, ja aizv\u0101kojumus izmanto t\u0101dos kritiskos lietojumos k\u0101 vakc\u012bnas, insul\u012bns un citi injic\u0113jami medikamenti.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Elastomeric-Closures-Penetrability-Test-A-Key-to-Medical-Packaging-Safety-1024x576.jpg\" alt=\"Elastom\u0113ru sl\u0113g\u0161anas testi - medic\u012bnisk\u0101 iepakojuma dro\u0161uma atsl\u0113ga\" class=\"wp-image-664\" srcset=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Elastomeric-Closures-Penetrability-Test-A-Key-to-Medical-Packaging-Safety-1024x576.jpg 1024w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Elastomeric-Closures-Penetrability-Test-A-Key-to-Medical-Packaging-Safety-300x169.jpg 300w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Elastomeric-Closures-Penetrability-Test-A-Key-to-Medical-Packaging-Safety-768x432.jpg 768w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Elastomeric-Closures-Penetrability-Test-A-Key-to-Medical-Packaging-Safety-1536x864.jpg 1536w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Elastomeric-Closures-Penetrability-Test-A-Key-to-Medical-Packaging-Safety-600x338.jpg 600w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Elastomeric-Closures-Penetrability-Test-A-Key-to-Medical-Packaging-Safety.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Elastom\u0113ra p\u0101rkl\u0101jumu herm\u0113tiskuma testa veik\u0161anas process<\/h2>\n\n\n\n<p>Port\u0101ls&nbsp;<strong>elastom\u0113ra aizdares caurlaid\u012bbas tests<\/strong>&nbsp;nov\u0113rt\u0113, cik liels sp\u0113ks ir vajadz\u012bgs, lai adata vai cits ass priek\u0161mets caurdurtu aizvaru. \u0160eit ir aprakst\u012bts, k\u0101 tiek veikts tests:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Parauga sagatavo\u0161ana<\/strong>: Elastom\u0113ra aizdares paraugs tiek nostiprin\u0101ts testa stiprin\u0101jum\u0101, kas to notur caurdur\u0161anas testa laik\u0101.<\/li>\n\n\n\n<li><strong>Adatu izv\u0113le<\/strong>: Test\u0101 tiek izmantota adata, kas prec\u012bzi imit\u0113 injekcij\u0101m vai inf\u016bzij\u0101m izmantojamo adatu veidu. T\u0101d\u0113j\u0101di tiek nodro\u0161in\u0101ts, ka tests imit\u0113 faktiskos apst\u0101k\u013cus, k\u0101dos sl\u0113gums tiktu caururbts.<\/li>\n\n\n\n<li><strong>Punkcijas testa izpilde<\/strong>: Adata tiek iedz\u012bta aizvar\u0101 ar kontrol\u0113tu \u0101trumu. Test\u0101 m\u0113ra sp\u0113ku, kas vajadz\u012bgs, lai adata iespiestos aizvar\u0101. To var veikt ar da\u017e\u0101diem \u0101trumiem un le\u0146\u0137iem, lai simul\u0113tu da\u017e\u0101dus caurdur\u0161anas scen\u0101rijus.<\/li>\n\n\n\n<li><strong>Datu anal\u012bze<\/strong>: Tiek re\u0123istr\u0113ts sp\u0113ks, kas nepiecie\u0161ams, lai caurdurtu aizvaru, un rezult\u0101ti tiek analiz\u0113ti. Ja sp\u0113ks ir maz\u0101ks par normat\u012bvajos standartos noteikto minim\u0101lo slieksni, tiek uzskat\u012bts, ka aizvars nav iztur\u0113jis testu.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">K\u0101 NPT-01 adatu punkcijas testeris uzlabo test\u0113\u0161anas precizit\u0101ti<\/h2>\n\n\n\n<p>Port\u0101ls&nbsp;<strong>NPT-01 Adatu punkcijas testeris<\/strong>&nbsp;ir \u012bpa\u0161i izstr\u0101d\u0101ts da\u017e\u0101du materi\u0101lu, tostarp elastom\u0113ru aizdares, iztur\u012bbas pret caurdur\u0161anu test\u0113\u0161anai. Tas nodro\u0161ina prec\u012bzu, uzticamu un efekt\u012bvu metodi, lai veiktu&nbsp;<strong>elastom\u0113ra aizdares caurlaid\u012bbas tests<\/strong>. L\u016bk, k\u0101 NPT-01 uzlabo test\u0113\u0161anas procesu:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Prec\u012bza sp\u0113ka m\u0113r\u012b\u0161ana<\/strong>: NPT-01 ar augstu precizit\u0101ti m\u0113ra sp\u0113ku, kas nepiecie\u0161ams, lai caurdurtu aizvaru. Tas nodro\u0161ina rezult\u0101tu ticam\u012bbu un konsekvenci, pal\u012bdzot ra\u017eot\u0101jiem noteikt, vai aizvars atbilst nepiecie\u0161amajiem standartiem.<\/li>\n\n\n\n<li><strong>Piel\u0101gojami testa iestat\u012bjumi<\/strong>: NPT-01 \u013cauj lietot\u0101jiem piel\u0101got t\u0101dus testa parametrus k\u0101 adatas tips, testa \u0101trums un sp\u0113ks, nodro\u0161inot elast\u012bbu un precizit\u0101ti, test\u0113jot da\u017e\u0101dus aizdares materi\u0101lus.<\/li>\n\n\n\n<li><strong>Ties\u012bbu aktu atbilst\u012bba<\/strong>: NPT-01 ir izstr\u0101d\u0101ts atbilsto\u0161i starptautiskajiem test\u0113\u0161anas standartiem, tostarp\u00a0<strong>USP 381<\/strong>, nodro\u0161inot, ka ra\u017eot\u0101ji var apstiprin\u0101t savu aizb\u0101\u017e\u0146u iztur\u012bbu pret caurdur\u0161anu saska\u0146\u0101 ar normat\u012bvaj\u0101m pras\u012bb\u0101m.<\/li>\n\n\n\n<li><strong>Lietot\u0101jam draudz\u012bga saskarne<\/strong>: Testerim ir lietot\u0101jam draudz\u012bgs PLC vad\u012bbas bloks un 7 collu sk\u0101rienekr\u0101ns, kas atvieglo darb\u012bbu un rezult\u0101tu uzraudz\u012bbu. Tas vienk\u0101r\u0161o test\u0113\u0161anas procesu un palielina produktivit\u0101ti.<\/li>\n\n\n\n<li><strong>Vair\u0101ku adatu opcijas<\/strong>: NPT-01 var apr\u012bkot ar da\u017e\u0101da veida adat\u0101m, t\u0101d\u0113j\u0101di nodro\u0161inot elast\u012bbu, lai veiktu testus ar da\u017e\u0101diem aizdares materi\u0101liem un simul\u0113tu da\u017e\u0101dus caurdur\u0161anas apst\u0101k\u013cus.<\/li>\n\n\n\n<li><strong>Ieb\u016bv\u0113ta datu glab\u0101\u0161ana<\/strong>: NPT-01 ir apr\u012bkots ar punktveida matricas printeri, kas ieraksta testa datus turpm\u0101kai atsaucei, t\u0101d\u0113j\u0101di atvieglojot ra\u017eot\u0101jiem dokument\u0113t un analiz\u0113t rezult\u0101tus laika gait\u0101.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">USP 381: Atbilst\u012bbas nodro\u0161in\u0101\u0161ana normat\u012bvajiem standartiem<\/h2>\n\n\n\n<p><strong>USP 381<\/strong>&nbsp;ir noteiktas ofici\u0101l\u0101s pras\u012bbas elastom\u0113ru aizv\u0101kojumiem, ko izmanto injic\u0113jamo z\u0101\u013cu iepakojum\u0101. Taj\u0101 ir nor\u0101d\u012bti aizb\u0101\u017e\u0146u veiktsp\u0113jas krit\u0113riji, tostarp to iztur\u012bba pret adatu caurdur\u0161anu. Atbilst\u012bba&nbsp;<strong>USP 381<\/strong>&nbsp;ir \u013coti svar\u012bga medic\u012bnas produktu ra\u017eot\u0101jiem, jo \u0161o standartu neiev\u0113ro\u0161ana var novest pie produktu atsauk\u0161anas vai regulat\u012bvaj\u0101m sankcij\u0101m.<\/p>\n\n\n\n<p>Port\u0101ls&nbsp;<strong>elastom\u0113ra aizdares caurlaid\u012bbas tests<\/strong>&nbsp;ir b\u016btiska noz\u012bme, lai nodro\u0161in\u0101tu, ka aizv\u0101ko\u0161anas izstr\u0101d\u0101jumi atbilst iztur\u012bbas pret caurdur\u0161anu un bl\u012bv\u0113juma integrit\u0101tes standartiem, ko nosaka&nbsp;<strong>USP 381<\/strong>. Izmantojot&nbsp;<strong>NPT-01 Adatu punkcijas testeris<\/strong>, ra\u017eot\u0101ji var prec\u012bzi nov\u0113rt\u0113t savu aizb\u0101\u017e\u0146u iztur\u012bbu pret caurdur\u0161anu un apstiprin\u0101t atbilst\u012bbu \u0161im b\u016btiskajam standartam.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Regul\u0101ras caurlaid\u012bbas testa veik\u0161anas priek\u0161roc\u012bbas<\/h2>\n\n\n\n<p>Regul\u0101ri veicot&nbsp;<strong>elastom\u0113ra aizdares caurlaid\u012bbas tests<\/strong>&nbsp;pied\u0101v\u0101 vair\u0101kas priek\u0161roc\u012bbas farm\u0101cijas nozares ra\u017eot\u0101jiem:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Nodro\u0161ina produkta uzticam\u012bbu<\/strong>: Konsekventa test\u0113\u0161ana pal\u012bdz ra\u017eot\u0101jiem saglab\u0101t elastom\u0113ru aizdares kvalit\u0101ti un uzticam\u012bbu.<\/li>\n\n\n\n<li><strong>Nov\u0113r\u0161 neveiksmes<\/strong>: Agr\u012bna nosl\u0113g\u0161anas materi\u0101lu nepiln\u012bbu identific\u0113\u0161ana var nov\u0113rst d\u0101rgi izmaks\u0101jo\u0161as k\u013c\u016bmes vai atsaukumus n\u0101kotn\u0113.<\/li>\n\n\n\n<li><strong>Atbalsta produktu izstr\u0101di<\/strong>: No caurlaid\u012bbas testa ieg\u016btie dati var pal\u012bdz\u0113t izstr\u0101d\u0101t jaunus aizdares materi\u0101lus un dizainu, t\u0101d\u0113j\u0101di radot lab\u0101kus izstr\u0101d\u0101jumus.<\/li>\n\n\n\n<li><strong>Uzlabo atbilst\u012bbu normat\u012bvajiem aktiem<\/strong>: Regul\u0101ri veicot testus un nodro\u0161inot atbilst\u012bbu standartiem, piem\u0113ram.\u00a0<strong>USP 381<\/strong>, ra\u017eot\u0101ji var izvair\u012bties no d\u0101rg\u0101m regul\u0113juma probl\u0113m\u0101m.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Secin\u0101jums<\/h2>\n\n\n\n<p>Port\u0101ls&nbsp;<strong>elastom\u0113ra aizdares caurlaid\u012bbas tests<\/strong>&nbsp;ir \u013coti svar\u012bgi, lai nodro\u0161in\u0101tu medic\u012bniskaj\u0101 iepakojum\u0101 izmantoto aizv\u0101kojumu dro\u0161\u012bbu, uzticam\u012bbu un veiktsp\u0113ju. P\u0101rbaudot elastom\u0113ru aizdares iztur\u012bbu pret caurdur\u0161anu, ra\u017eot\u0101ji var garant\u0113t, ka vi\u0146u izstr\u0101d\u0101jumi atbilst nepiecie\u0161amajiem normat\u012bvajiem standartiem, piem\u0113ram.&nbsp;<strong>USP 381<\/strong>, un nodro\u0161ina dro\u0161u plombu injic\u0113jamiem medikamentiem. .&nbsp;<strong>NPT-01 Adatu punkcijas testeris<\/strong>&nbsp;ir v\u0113rt\u012bgs r\u012bks \u0161o testu veik\u0161anai, kas nodro\u0161ina prec\u012bzu, uzticamu un elast\u012bgu test\u0113\u0161anas iesp\u0113ju. Ar NPT-01 pal\u012bdz\u012bbu ra\u017eot\u0101ji var nodro\u0161in\u0101t, ka vi\u0146u elastom\u0113ru aizdares atbilst visaugst\u0101kajiem standartiem, aizsarg\u0101jot gan izstr\u0101d\u0101jumu, gan pacientu.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h2 class=\"wp-block-heading\">Bie\u017e\u0101k uzdoto jaut\u0101jumu sada\u013ca<\/h2>\n\n\n\n<p><strong>1. Kas ir elastom\u0113ra aizdares caurlaid\u012bbas tests?<\/strong><br>Elastom\u0113ra aizdares caurlaid\u012bbas test\u0101 m\u0113ra sp\u0113ku, kas nepiecie\u0161ams, lai adata caururbtu elastom\u0113ra aizvaru, nodro\u0161inot t\u0101 iztur\u012bbu pret caurdur\u0161anu un sp\u0113ju saglab\u0101t sterilu herm\u0113tiskumu.<\/p>\n\n\n\n<p><strong>2. K\u0101p\u0113c NPT-01 adatas punkcijas testeris ir svar\u012bgs elastom\u0113ra aizb\u0101\u017e\u0146u test\u0113\u0161anai?<\/strong><br>NPT-01 adatu caurdur\u0161anas testeris nodro\u0161ina prec\u012bzus un atk\u0101rtojamus caurdur\u0161anas pretest\u012bbas m\u0113r\u012bjumus, nodro\u0161inot, ka aizdares atbilst normat\u012bvajiem standartiem, piem\u0113ram.&nbsp;<strong>USP 381<\/strong>&nbsp;iztur\u012bbai pret caurdur\u0161anu un bl\u012bv\u0113juma integrit\u0101tei.<\/p>\n\n\n\n<p><strong>3. K\u0101 elastom\u0113ra aizdares caurlaid\u012bbas tests nodro\u0161ina atbilst\u012bbu USP 381?<\/strong><br>Test\u0101 nov\u0113rt\u0113, vai elastom\u0113ra aizdares var iztur\u0113t caurdur\u0161anas sp\u0113ku, k\u0101 nor\u0101d\u012bts \u0161ajos noteikumos.&nbsp;<strong>USP 381<\/strong>, nodro\u0161inot, ka tie atbilst injic\u0113jamo z\u0101\u013cu iepakojuma normat\u012bvaj\u0101m pras\u012bb\u0101m.<\/p>\n\n\n\n<p><strong>4. K\u0101da veida materi\u0101lus var test\u0113t ar NPT-01?<\/strong><br>Ar NPT-01 var test\u0113t pla\u0161u materi\u0101lu kl\u0101stu, tostarp elastom\u0113ru aizb\u0101\u017e\u0146us, gumijas aizb\u0101\u017e\u0146us, cimdus un citus medic\u012bn\u0101 izmantojamus aizsargmateri\u0101lus.<\/p>\n\n\n\n<p><strong>5. Cik bie\u017ei j\u0101veic elastom\u0113ra aizdares caurlaid\u012bbas tests?<\/strong><br>Tests j\u0101veic regul\u0101ri k\u0101 da\u013ca no kvalit\u0101tes kontroles programmas, lai nodro\u0161in\u0101tu elastom\u0113ru aizb\u0101\u017e\u0146u konsekventu darb\u012bbu un atbilst\u012bbu normat\u012bvajiem standartiem.<\/p>","protected":false},"excerpt":{"rendered":"<p>Elastomeric closures are commonly used in pharmaceutical and medical packaging to seal injectable vials, syringes, and other containers. These closures play a crucial role in maintaining the sterility and safety of the packaged contents. To ensure their effectiveness, an&nbsp;elastomeric closures penetrability test&nbsp;is conducted to evaluate the closure&#8217;s resistance to puncture. This article explores the significance [&hellip;]<\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-663","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/posts\/663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/comments?post=663"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/posts\/663\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/media?parent=663"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/categories?post=663"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.materialstests.com\/lv\/wp-json\/wp\/v2\/tags?post=663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}