{"id":2774,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/ts-01-syringe-tube-stiffness-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"ts-01-syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/lt\/products\/ts-01-syringe-tube-stiffness-tester.html","title":{"rendered":"TS-01 \u0161virk\u0161to vamzdelio standumo testeris"},"content":{"rendered":"<h2><strong>Ap\u017evalga<\/strong><\/h2>\n<p>Svetain\u0117\u00a0<strong><a href=\"https:\/\/www.materialstests.com\/lt\/medical-device-tester.html\/\">\u0160virk\u0161to vamzdelio standumo testeris<\/a>\u00a0(TS-01)<\/strong>\u00a0tai labai tikslus bandymo prietaisas, skirtas medicinini\u0173 vamzdeli\u0173, ypa\u010d poodini\u0173 adat\u0173 ir \u0161virk\u0161t\u0173, standumui matuoti. Kaip\u00a0<strong>standumas<\/strong>\u00a0turi tiesiogin\u0117s \u012ftakos medicinini\u0173 vamzdeli\u0173 saugai, lankstumui ir bendram veikimui, tiksliam\u00a0<strong>standumo bandymai<\/strong>\u00a0labai svarbu u\u017etikrinti, kad vamzd\u017eiuose b\u016bt\u0173 i\u0161laikyta tinkama mechaninio stiprumo ir lankstumo pusiausvyra. Pernelyg stand\u016bs vamzdeliai gali padidinti l\u016b\u017eimo ar trapi\u0173 l\u016b\u017ei\u0173 rizik\u0105, o pernelyg mink\u0161ti vamzdeliai gali sulenkti, sugadinti ir sukelti nesaugi\u0173 medicinini\u0173 proced\u016br\u0173 pavoj\u0173.<\/p>\n<p>Svetain\u0117\u00a0<strong>Medicinin\u0117s adatos standumo testeris<\/strong>\u00a0sukurtas taip, kad imituot\u0173 realias s\u0105lygas, veikiant vamzd\u017eio centr\u0105 tam tikra j\u0117ga ir matuojant jo deformacij\u0105. Taip u\u017etikrinama, kad vamzdeliai b\u016bt\u0173 pakankamai stand\u016bs, kad saugiai veikt\u0173 medicinin\u0117je praktikoje, pavyzd\u017eiui, atliekant injekcijas, infuzijas ir kitas svarbias proced\u016bras.<\/p>\n<hr \/>\n<h2><strong>Parai\u0161kos<\/strong><\/h2>\n<p>TS-01 \u0161virk\u0161to vamzdelio standumo testeris pla\u010diai naudojamas\u00a0<strong>medicinos, farmacijos ir pakavimo pramon\u0117.<\/strong>\u00a0kai tiksli vamzd\u017ei\u0173 charakteristik\u0173 kontrol\u0117 yra labai svarbi produkt\u0173 saugai u\u017etikrinti. Pagrindin\u0117s jo naudojimo sritys:<\/p>\n<ul>\n<li><strong>\u0160virk\u0161t\u0173 gamyba<\/strong>: U\u017etikrinti, kad \u0161virk\u0161tai, poodin\u0117s adatos ir kateteriai b\u016bt\u0173 reikiamo standumo, kad b\u016bt\u0173 suma\u017einta rizika juos \u012fdedant ir naudojant.<\/li>\n<li><strong>Medicinos prietais\u0173 moksliniai tyrimai ir pl\u0117tra<\/strong>: Nauj\u0173 medicinini\u0173 vamzdeli\u0173 konstrukcij\u0173 ir med\u017eiag\u0173, naudojam\u0173 medicininiams vamzdeliams, bandymai, siekiant u\u017etikrinti atitikt\u012f tarptautiniams saugos standartams, pvz.\u00a0<strong>ISO 9626<\/strong>.<\/li>\n<li><strong>Kokyb\u0117s kontrol\u0117<\/strong>: \u012eprastinis medicinini\u0173 pakavimo med\u017eiag\u0173, pavyzd\u017eiui, lanks\u010di\u0173 vamzdeli\u0173 ir injekcij\u0173 viet\u0173, bandymas, siekiant u\u017etikrinti, kad jos atitikt\u0173 teis\u0117s akt\u0173 reikalavimus ir veikt\u0173 taip, kaip numatyta klinikinio naudojimo metu.<\/li>\n<li><strong>Medicinin\u0117 pakuot\u0117<\/strong>: Patikrinama, ar medicinin\u0117se pakuot\u0117se naudojami vamzdeliai n\u0117ra nei per kieti (d\u0117l to jie gali b\u016bti trap\u016bs), nei per mink\u0161ti (d\u0117l to gali kilti lankstumo problem\u0173 naudojimo metu).<\/li>\n<li><strong>Farmacijos pramon\u0117<\/strong>: U\u017etikrinti, kad vaist\u0173 tiekimo sistema b\u016bt\u0173 saugi ir patikima, i\u0161bandant \u0161virk\u0161tuose ir infuzij\u0173 rinkiniuose naudojamus vamzdelius.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>B\u016btinyb\u0117<\/strong><\/h2>\n<p>Medicinos pramon\u0117je,\u00a0<strong>vamzd\u017eio standumas<\/strong>\u00a0yra ne tik kokyb\u0117s savyb\u0117 - tai\u00a0<strong>kritinis saugos koeficientas<\/strong>. \u0160virk\u0161to ar poodin\u0117s adatos standumas turi \u012ftakos bendram jo veikimui ir\u00a0<strong>netinkamas standumas<\/strong>\u00a0gali sukelti \u012fvairi\u0173 veiklos problem\u0173, pavyzd\u017eiui, sunkum\u0173 \u012fdedant, l\u016b\u017etant ar netinkamai veikiant medicinini\u0173 proced\u016br\u0173 metu. Per stand\u016bs vamzdeliai gali tapti trap\u016bs ir, veikiami \u012ftampos, sugesti, o tai gali lemti katastrofi\u0161k\u0105 gedim\u0105 proced\u016bros metu.<\/p>\n<p>Prie\u0161ingai, per daug lankst\u016bs ar mink\u0161ti vamzdeliai gali b\u016bti sulenkti, susilenkti ar deformuotis, o tai taip pat gali sukelti klaid\u0173 atliekant medicinines proced\u016bras ar net pakenkti sterilumui. \u0160virk\u0161t\u0173 vamzdeli\u0173 standumo testeris yra svarbi priemon\u0117\u00a0<strong>matuoti ir tikrinti.<\/strong>\u00a0kad \u0161iuose prietaisuose naudojami vamzdeliai b\u016bt\u0173 optimaliai pritaikyti saugai, lankstumui ir tvirtumui.<\/p>\n<hr \/>\n<h2><strong>Veikimo principas<\/strong><\/h2>\n<p>TS-01\u00a0<strong>\u0160virk\u0161to vamzdelio standumo testeris<\/strong>\u00a0veikia pagal paprast\u0105, bet labai veiksming\u0105 princip\u0105. Atliekant bandym\u0105 vamzd\u017eio centre, kuris yra paremtas abiejuose galuose, veikia tam tikra j\u0117ga (iki 60 N). Testeris matuoja\u00a0<strong>deformacija<\/strong>\u00a0vamzd\u017ei\u0173, veikiant \u0161iai j\u0117gai.<\/p>\n<h4>Pagrindin\u0117s savyb\u0117s:<\/h4>\n<ul>\n<li><strong>J\u0117gos taikymas<\/strong>: 60\u00b0 kampu pasvir\u0119s ir 1 mm spindulio cilindro formos st\u016bmoklis veikia vamzdel\u012f kontroliuojama \u017eemyn nukreipta j\u0117ga.<\/li>\n<li><strong>Deformacijos matavimas<\/strong>: Testeris matuoja\u00a0<strong>deformacija<\/strong>\u00a0vamzd\u017eio tikslumu \u00b10,01 mm, o tai rodo med\u017eiagos standum\u0105.<\/li>\n<li><strong>J\u0117gos diapazonas<\/strong>: Prietaisu galima bandyti vamzd\u017eius, kuri\u0173 j\u0117ga yra nuo 1 N iki 60 N.\u00a0<strong>universalus asortimentas<\/strong>\u00a0matavim\u0173.<\/li>\n<\/ul>\n<p>\u0160io bandymo rezultatas tiesiogiai susij\u0119s su vamzd\u017ei\u0173 standumu ir padeda gamintojams \u012fsitikinti, kad gaminys nevir\u0161ija leistin\u0173 norm\u0173.\u00a0<strong>sauga ir funkcionalumas<\/strong>\u00a0medicinin\u0117je aplinkoje.<\/p>\n<hr \/>\n<h2><strong>Technin\u0117s specifikacijos<\/strong><\/h2>\n<p>TS-01 \u0161virk\u0161to vamzdelio standumo testeris pasi\u017eymi\u00a0<strong>didelio tikslumo funkcijos<\/strong>\u00a0d\u0117l kuri\u0173 jis yra nepakei\u010diamas medicinos prietais\u0173 bandym\u0173 \u012frankis. Pateikiame pagrindines specifikacijas:<\/p>\n<ul>\n<li><strong>Fiksuota j\u0117ga<\/strong>: 60 N (arba pagal u\u017esakym\u0105)<\/li>\n<li><strong>Bandymo greitis<\/strong>: Reguliuojama nuo 1 iki 500 mm\/min.<\/li>\n<li><strong>Tikslumas<\/strong>: \u00b10,01 mm deformacijos matavimas<\/li>\n<li><strong>Maitinimo \u0161altinis<\/strong>: Nuo 110 V iki 220 V kintamosios srov\u0117s<\/li>\n<li><strong>Valdymo sistema<\/strong>: PLC valdomas su\u00a0<strong>7 coli\u0173 HMI jutiklinis ekranas<\/strong>\u00a0kad b\u016bt\u0173 patogu valdyti<\/li>\n<li><strong>Bandymo \u012ftaisas<\/strong>: Galima naudoti kelis tvirtinimo \u012ftaisus, skirtus \u017eemyn nukreiptos j\u0117gos bandymams<\/li>\n<li><strong>Apsauga nuo perkrovos<\/strong>: \u012emontuota apsauga nuo perkrovos, kad prietaisas neb\u016bt\u0173 sugadintas<\/li>\n<li><strong>Mikroprinteris<\/strong>: Nedelsiant atspausdinti tyrimo rezultatus<\/li>\n<\/ul>\n<p>\u0160ie\u00a0<strong>didelio tikslumo galimyb\u0117s<\/strong>\u00a0u\u017etikrina, kad \u0161virk\u0161t\u0173 vamzdeli\u0173 standumas b\u016bt\u0173 matuojamas tiksliai ir patikimai, tod\u0117l gamintojai ir reguliavimo institucijos gali pasitik\u0117ti gautais rezultatais.<\/p>\n<hr \/>\n<h2><strong>Privalumai<\/strong><\/h2>\n<p>TS-01 \u0161virk\u0161tini\u0173 vamzdeli\u0173 standumo testeris turi kelet\u0105 privalum\u0173, palyginti su tradiciniais standumo testavimo metodais:<\/p>\n<ul>\n<li><strong>Didelis tikslumas<\/strong>: Svetain\u0117\u00a0<strong>\u00b10,01 mm<\/strong>\u00a0deformacijos matavimo tikslumas u\u017etikrina itin patikimus rezultatus svarbiausiose srityse.<\/li>\n<li><strong>Platus pritaikymo spektras<\/strong>: Reguliuojama j\u0117ga iki 60 N ir kei\u010diamas bandymo greitis, tod\u0117l TS-01 galima pritaikyti \u012fvairiems vamzd\u017ei\u0173 tipams ir bandym\u0173 reikalavimams.<\/li>\n<li><strong>Naudojimo paprastumas<\/strong>: Svetain\u0117\u00a0<strong>PLC valdymo sistema<\/strong>\u00a0ir\u00a0<strong>jutiklinio ekrano valdymas<\/strong>\u00a0supaprastinti testavimo proces\u0105 ir padaryti j\u012f patog\u0173 net ir tiems, kurie neturi dideli\u0173 technini\u0173 \u017eini\u0173.<\/li>\n<li><strong>Patvarumas<\/strong>: D\u0117l apsaugos nuo perkrovos ir automatinio gr\u012f\u017eimo po kiekvieno bandymo TS-01 u\u017etikrina ilgaam\u017ei\u0161kum\u0105 ir patikimum\u0105 net ir didel\u0117s apimties bandym\u0173 aplinkoje.<\/li>\n<li><strong>Standart\u0173 laikymasis<\/strong>: Testeris suprojektuotas taip, kad atitikt\u0173\u00a0<strong>ISO 9626<\/strong>\u00a0ir\u00a0<strong>GB\/T18457<\/strong>\u00a0standartus, u\u017etikrinant, kad visi matavimai atitikt\u0173 tarptautines saugos ir na\u0161umo gaires.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Konfig\u016bracijos ir priedai<\/strong><\/h2>\n<p>Svetain\u0117\u00a0<strong>TS-01 \u0161virk\u0161to vamzdelio standumo testeris<\/strong>\u00a0turi kelet\u0105 standartini\u0173 konfig\u016bracij\u0173 ir papildom\u0173 pried\u0173, kad atitikt\u0173 \u012fvairius bandym\u0173 poreikius:<\/p>\n<ul>\n<li><strong>Pagrindin\u0117 ma\u0161ina<\/strong>: Sudarytas i\u0161 judan\u010dios kry\u017emin\u0117s galvut\u0117s ir bandymo st\u016bmoklio, prijungto prie apkrovos elemento.<\/li>\n<li><strong>Bandomasis st\u016bmoklis<\/strong>: Tikslus st\u016bmoklis, kurio galas turi buk\u0105 plei\u0161t\u0105 ir kuris skirtas tam tikrai j\u0117gai \u012f vamzdel\u012f nukreipti.<\/li>\n<li><strong>Bandym\u0173 keptuv\u0117<\/strong>: D\u0117klas, kuriame bandym\u0173 metu saugiai laikomi vamzdeliai.<\/li>\n<li><strong>Maitinimo laidas ir saugiklis<\/strong>: B\u016btina eksploatacijai ir saugai.<\/li>\n<\/ul>\n<p>Papildomi priedai, pvz.\u00a0<strong>pritaikyti \u012frenginiai<\/strong>\u00a0\u012fvairioms bandym\u0173 konfig\u016bracijoms, gali b\u016bti pridedami priklausomai nuo bandom\u0173 vamzd\u017ei\u0173.<\/p>\n<hr \/>\n<h2><strong>Standartai<\/strong><\/h2>\n<p>Svetain\u0117\u00a0<strong>TS-01 \u0161virk\u0161to vamzdelio standumo testeris<\/strong>\u00a0sukurta taip, kad atitikt\u0173\u00a0<strong>tarptautiniai standartai<\/strong>\u00a0medicinos prietais\u0173 bandymams, \u012fskaitant:<\/p>\n<ul>\n<li><strong>ISO 9626<\/strong>: Apibr\u0117\u017eiamos reikiamos mechanin\u0117s ner\u016bdijan\u010dio plieno vamzd\u017ei\u0173, naudojam\u0173 adatoms gaminti, savyb\u0117s. Standarte pateikiami plienini\u0173 vamzdeli\u0173 stiprumo ir ilgaam\u017ei\u0161kumo vertinimo metodai, skirti u\u017etikrinti, kad jie atitikt\u0173 galutinio gaminio reikalavimus. Reikiama j\u0117ga priklauso nuo adatos gabarito ir sieneli\u0173 storio - dviej\u0173 veiksni\u0173, nuo kuri\u0173 priklauso adatos paskirtis. Bandymai atliekami naudojant trij\u0173 ta\u0161k\u0173 lenkimo mazg\u0105, kad b\u016bt\u0173 nustatytas med\u017eiagos standumas. Be to, atliekamas konsolinio lenkimo bandymas, kad b\u016bt\u0173 \u012fvertintas vamzdeli\u0173 atsparumas l\u016b\u017eiams. \u0160is bandymas labai svarbus siekiant u\u017etikrinti, kad adata atlaikyt\u0173 \u0161lyties j\u0117gas, kurios gali atsirasti klinikin\u0117je aplinkoje.<\/li>\n<li><strong>GB\/T18457<\/strong>: Kinijos nacionaliniai medicinos prietais\u0173, \u012fskaitant \u0161virk\u0161tus ir vamzdelius, bandymo standartai.<\/li>\n<\/ul>\n<p>\u0160ie standartai u\u017etikrina, kad TS-01 testeris atitinka visame pasaulyje pripa\u017eintus saugos, kokyb\u0117s ir eksploatacini\u0173 savybi\u0173 reikalavimus, tod\u0117l jis idealiai tinka naudoti reguliuojamoje aplinkoje.<\/p>\n<hr \/>\n<h2><strong>Parama ir mokymas<\/strong><\/h2>\n<p><a href=\"https:\/\/www.materialstests.com\/lt\/\"><strong>Cell Instruments<\/strong><\/a>\u00a0pasi\u016blymai\u00a0<strong>visapusi\u0161ka parama<\/strong>\u00a0u\u017e\u00a0<strong>TS-01 \u0161virk\u0161to vamzdelio standumo testeris<\/strong>, \u012fskaitant:<\/p>\n<ul>\n<li><strong>Techninis palaikymas<\/strong>: Galimyb\u0117 gauti ekspert\u0173 pagalb\u0105 \u0161alinant trikd\u017eius ir kalibruojant.<\/li>\n<li><strong>Mokymas<\/strong>: Darbuotoj\u0173 mokymas vietoje arba internetu, kaip naudotis \u012frenginiu ir interpretuoti tyrim\u0173 rezultatus.<\/li>\n<li><strong>Programin\u0117s \u012frangos atnaujinimai<\/strong>: Reguliariai atnaujinama ma\u0161inos programin\u0117 \u012franga, kad b\u016bt\u0173 patobulintos funkcijos ir u\u017etikrinta atitiktis besikei\u010diantiems pramon\u0117s standartams.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Overview The\u00a0Syringe Tube Stiffness Tester\u00a0(TS-01)\u00a0is a high-precision testing device designed to measure the stiffness of medical tubing, particularly hypodermic needles and syringes. As\u00a0stiffness\u00a0directly impacts the safety, flexibility, and overall performance of medical tubing, accurate\u00a0stiffness testing\u00a0is essential to ensure that tubing maintains the right balance of mechanical strength and flexibility. Overly stiff tubing can increase the [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[],"class_list":["post-2774","products","type-products","status-publish","hentry","products-categories-medical-device-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/lt\/wp-json\/wp\/v2\/products\/2774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/lt\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/lt\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/lt\/wp-json\/wp\/v2\/products\/2774\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/lt\/wp-json\/wp\/v2\/media?parent=2774"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/lt\/wp-json\/wp\/v2\/products-categories?post=2774"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/lt\/wp-json\/wp\/v2\/productstags?post=2774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}