1. Introduction of Concora Medium Fluter
Concora Medium Fluter is used as a sampling machine for corrugated board as standard to A flute and other optional flutes.
The sample is then taken to be tested to determine the compressibility strength using the C.C.T. (Corrugated Crush Test) & the C.M.T. (Corrugating Medium Test)
Concora Medium Fluter can produce 0.5 inch (12.7 mm) wide samples. The two corrugating discs inside have a good heat distribution, which is essential for forming the correct groove.
2.Advantages
The Concora Medium Fluter is a sampling machine that can prepare fluting samples for CMT or CCT testing. It’s easy to use, meets industry standards, and can help prepare corrugated samples for CMT and CCT tests.
emperature accuracy: The temperature can be set accurately to 1° C.
Spring-loaded system: The system is spring-loaded and easily adjustable to help reduce maintenance costs.
Test flute preparation: The Concora Fluter is designed to form test flutes in medium for crush tests.
3. Test Principle
After turning on and temperature setting, wait for the disc temp to reach set value.
Then put the sample from top, and the corrugated sample will come out from below.
The sample is matched with the corresponding CMT rack and comb or CCT sample holder. Then sample is analyzed by a high-precision compressive strength tester.

4. Features
Rugged and durable equipment
The different corrugating discs can be replaced
Adjustable pressure range and it can be calibrated
Vertical design simplifies sample feeding
The built-in heating inside the discs means faster and uniform temp distribution.
Precise temperature control
The space-saving design.

5. Specifications
| Radius Of Teeth At Peak | R 1.5 士 0.1mm |
| Radius Of Teeth At Base | R 2.0 士 0.1mm |
| Depth Of Teeth | 4.75+/-0.05mm |
| Distance Between Teeth | 8.50 ± 0.05 mm |
| Flute Type | A (standard) |
| Speed | 4.5 ± 0.1 r/min |
| Sample Width | 12.7 mm |
| Pressure Range | 50-140 N Force indication accuracy ± 2 N |
| Temperature Range | Ambient~200℃ |
| Standard Working Temperature | 175 ℃ ± 8℃ |
| Temperature Resolution | 1℃ |
| Power | AC 220V 50Hz |
6. Standards
CCT: ISO 16945, TAPPI T843,GB/T 40168
CMT: ISO 7263, TAPPI T843, EN ISO 7263-1, GB/T 2679, QB/T 1061