{"id":2774,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/ts-01-syringe-tube-stiffness-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"ts-01-syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/hu\/products\/ts-01-syringe-tube-stiffness-tester.html","title":{"rendered":"TS-01 fecskend\u0151cs\u0151 merevs\u00e9gm\u00e9r\u0151 TS-01"},"content":{"rendered":"<h2><strong>\u00c1ttekint\u00e9s<\/strong><\/h2>\n<p>A\u00a0<strong><a href=\"https:\/\/www.materialstests.com\/hu\/medical-device-tester.html\/\">Fecskend\u0151cs\u0151 merevs\u00e9gm\u00e9r\u0151<\/a>\u00a0(TS-01)<\/strong>\u00a0egy nagy pontoss\u00e1g\u00fa m\u00e9r\u0151m\u0171szer, amelyet orvosi cs\u00f6vek, k\u00fcl\u00f6n\u00f6sen injekci\u00f3s t\u0171k \u00e9s fecskend\u0151k merevs\u00e9g\u00e9nek m\u00e9r\u00e9s\u00e9re terveztek. Mivel\u00a0<strong>merevs\u00e9g<\/strong>\u00a0k\u00f6zvetlen\u00fcl befoly\u00e1solja az orvosi cs\u00f6vek biztons\u00e1g\u00e1t, rugalmass\u00e1g\u00e1t \u00e9s \u00e1ltal\u00e1nos teljes\u00edtm\u00e9ny\u00e9t, a pontos\u00a0<strong>merevs\u00e9gi vizsg\u00e1lat<\/strong>\u00a0Alapvet\u0151 fontoss\u00e1g\u00fa annak biztos\u00edt\u00e1sa, hogy a cs\u0151 megfelel\u0151 egyens\u00falyt tartson fenn a mechanikai szil\u00e1rds\u00e1g \u00e9s a rugalmass\u00e1g k\u00f6z\u00f6tt. A t\u00fal merev cs\u0151 n\u00f6velheti a t\u00f6r\u00e9s vagy a rideg t\u00f6r\u00e9s kock\u00e1zat\u00e1t, m\u00edg a t\u00fal puha cs\u0151 hajl\u00edt\u00e1shoz, s\u00e9r\u00fcl\u00e9shez \u00e9s potenci\u00e1lisan vesz\u00e9lyes orvosi beavatkoz\u00e1sokhoz vezethet.<\/p>\n<p>A\u00a0<strong>Orvosi t\u0171kem\u00e9nys\u00e9gm\u00e9r\u0151<\/strong>\u00a0\u00fagy lett kialak\u00edtva, hogy a cs\u0151 k\u00f6zep\u00e9re gyakorolt meghat\u00e1rozott er\u0151 hat\u00e1s\u00e1ra m\u00e9rje annak alakv\u00e1ltoz\u00e1s\u00e1t, ezzel szimul\u00e1lva a val\u00f3s k\u00f6r\u00fclm\u00e9nyeket. Ez biztos\u00edtja, hogy a cs\u0151 rendelkezzen a sz\u00fcks\u00e9ges merevs\u00e9ggel ahhoz, hogy biztons\u00e1gosan m\u0171k\u00f6dj\u00f6n orvosi alkalmaz\u00e1sokban, p\u00e9ld\u00e1ul injekci\u00f3k, inf\u00fazi\u00f3k \u00e9s egy\u00e9b kritikus beavatkoz\u00e1sok sor\u00e1n.<\/p>\n<hr \/>\n<h2><strong>Alkalmaz\u00e1sok<\/strong><\/h2>\n<p>A TS-01 fecskend\u0151cs\u0151-merevs\u00e9gm\u00e9r\u0151t sz\u00e9les k\u00f6rben haszn\u00e1lj\u00e1k a\u00a0<strong>az orvosi, gy\u00f3gyszeripari \u00e9s csomagol\u00f3ipar<\/strong>\u00a0ahol a cs\u00f6vek tulajdons\u00e1gainak pontos szab\u00e1lyoz\u00e1sa elengedhetetlen a term\u00e9kbiztons\u00e1g szempontj\u00e1b\u00f3l. F\u0151bb alkalmaz\u00e1si ter\u00fcletei a k\u00f6vetkez\u0151k:<\/p>\n<ul>\n<li><strong>Fecskend\u0151gy\u00e1rt\u00e1s<\/strong>: Gondoskodni arr\u00f3l, hogy a fecskend\u0151k, injekci\u00f3s t\u0171k \u00e9s kat\u00e9terek rendelkezzenek a sz\u00fcks\u00e9ges merevs\u00e9ggel a behelyez\u00e9s \u00e9s a haszn\u00e1lat sor\u00e1n felmer\u00fcl\u0151 kock\u00e1zatok minimaliz\u00e1l\u00e1sa \u00e9rdek\u00e9ben.<\/li>\n<li><strong>Orvostechnikai eszk\u00f6z\u00f6k kutat\u00e1sa \u00e9s fejleszt\u00e9se<\/strong>: Az orvosi cs\u00f6vek gy\u00e1rt\u00e1s\u00e1hoz haszn\u00e1lt \u00faj kialak\u00edt\u00e1sok \u00e9s anyagok tesztel\u00e9se a nemzetk\u00f6zi biztons\u00e1gi szabv\u00e1nyoknak val\u00f3 megfelel\u00e9s \u00e9rdek\u00e9ben, p\u00e9ld\u00e1ul\u00a0<strong>ISO 9626<\/strong>.<\/li>\n<li><strong>Min\u0151s\u00e9gellen\u0151rz\u00e9s<\/strong>: Az orvosi csomagol\u00f3anyagok \u2013 p\u00e9ld\u00e1ul a rugalmas cs\u00f6vek \u00e9s az injekci\u00f3s helyek \u2013 rendszeres vizsg\u00e1lata annak biztos\u00edt\u00e1sa \u00e9rdek\u00e9ben, hogy azok megfeleljenek a szab\u00e1lyoz\u00e1si k\u00f6vetelm\u00e9nyeknek, \u00e9s a klinikai haszn\u00e1lat sor\u00e1n a tervezett m\u00f3don m\u0171k\u00f6djenek.<\/li>\n<li><strong>Orvosi csomagol\u00e1s<\/strong>: Annak ellen\u0151rz\u00e9se, hogy az orvosi csomagol\u00e1sokban haszn\u00e1lt cs\u00f6vek ne legyenek sem t\u00fal merevek (ami t\u00f6r\u00e9kenny\u00e9 teheti \u0151ket), sem t\u00fal puhaak (ami haszn\u00e1lat k\u00f6zben rugalmass\u00e1gi probl\u00e9m\u00e1kat okozhat).<\/li>\n<li><strong>Gy\u00f3gyszeripar<\/strong>: A gy\u00f3gyszeradagol\u00f3 rendszer biztons\u00e1goss\u00e1g\u00e1nak \u00e9s megb\u00edzhat\u00f3s\u00e1g\u00e1nak biztos\u00edt\u00e1sa a fecskend\u0151kben \u00e9s inf\u00fazi\u00f3s k\u00e9szletekben haszn\u00e1lt cs\u00f6vek vizsg\u00e1lat\u00e1val.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Sz\u00fcks\u00e9gess\u00e9g<\/strong><\/h2>\n<p>Az eg\u00e9szs\u00e9g\u00fcgyi \u00e1gazatban,\u00a0<strong>cs\u0151 merevs\u00e9ge<\/strong>\u00a0nem csup\u00e1n egy min\u0151s\u00e9gi jellemz\u0151 \u2013 hanem egy\u00a0<strong>kritikus biztons\u00e1gi t\u00e9nyez\u0151<\/strong>. A fecskend\u0151 vagy a b\u0151r al\u00e1 sz\u00far\u00f3 t\u0171 merevs\u00e9ge befoly\u00e1solja annak \u00e1ltal\u00e1nos teljes\u00edtm\u00e9ny\u00e9t, \u00e9s\u00a0<strong>nem megfelel\u0151 merevs\u00e9g<\/strong>\u00a0ez k\u00fcl\u00f6nf\u00e9le m\u0171k\u00f6d\u00e9si probl\u00e9m\u00e1khoz vezethet, p\u00e9ld\u00e1ul bevezet\u00e9si neh\u00e9zs\u00e9gekhez, t\u00f6r\u00e9shez vagy a beavatkoz\u00e1s sor\u00e1n fell\u00e9p\u0151 m\u0171k\u00f6d\u00e9si zavarokhoz. A t\u00fal merev cs\u0151 terhel\u00e9s hat\u00e1s\u00e1ra t\u00f6r\u00e9kenny\u00e9 v\u00e1lhat \u00e9s meghib\u00e1sodhat, ami a beavatkoz\u00e1s sor\u00e1n katasztrof\u00e1lis k\u00f6vetkezm\u00e9nyekkel j\u00e1rhat.<\/p>\n<p>Ezzel szemben a t\u00fal rugalmas vagy puha cs\u00f6vek hajl\u00edt\u00e1shoz, csavarod\u00e1shoz vagy deform\u00e1l\u00f3d\u00e1shoz vezethetnek, ami szint\u00e9n hib\u00e1kat okozhat az orvosi beavatkoz\u00e1sok sor\u00e1n, vagy ak\u00e1r a sterilit\u00e1st is vesz\u00e9lyeztetheti. A fecskend\u0151cs\u0151-merevs\u00e9gm\u00e9r\u0151 elengedhetetlen eszk\u00f6z\u00a0<strong>m\u00e9rni \u00e9s ellen\u0151rizni<\/strong>\u00a0hogy az ezekben az eszk\u00f6z\u00f6kben haszn\u00e1lt cs\u00f6vek a biztons\u00e1g, a rugalmass\u00e1g \u00e9s a szil\u00e1rds\u00e1g szempontj\u00e1b\u00f3l optimaliz\u00e1ltak.<\/p>\n<hr \/>\n<h2><strong>M\u0171k\u00f6d\u00e9si elv<\/strong><\/h2>\n<p>A TS-01\u00a0<strong>Fecskend\u0151cs\u0151 merevs\u00e9gm\u00e9r\u0151<\/strong>\u00a0egyszer\u0171, de rendk\u00edv\u00fcl hat\u00e9kony elven m\u0171k\u00f6dik. A vizsg\u00e1lat sor\u00e1n egy meghat\u00e1rozott er\u0151t (legfeljebb 60 N) gyakorolnak a cs\u0151 k\u00f6zep\u00e9re, amelyet mindk\u00e9t v\u00e9g\u00e9n megt\u00e1masztanak. A vizsg\u00e1lati berendez\u00e9s m\u00e9ri a\u00a0<strong>elt\u00e9r\u00edt\u00e9s<\/strong>\u00a0a cs\u0151nek az alkalmazott er\u0151re adott reakci\u00f3ja.<\/p>\n<h4>Kulcsfontoss\u00e1g\u00fa jellemz\u0151k:<\/h4>\n<ul>\n<li><strong>Er\u0151hat\u00e1s<\/strong>: Egy tompa, \u00e9k alak\u00fa, 60\u00b0-os sz\u00f6gben megd\u00f6nt\u00f6tt, 1 mm \u00e1tm\u00e9r\u0151j\u0171 hengeres dugatty\u00fa szab\u00e1lyozott lefel\u00e9 ir\u00e1nyul\u00f3 er\u0151t fejt ki a cs\u0151re.<\/li>\n<li><strong>Hajl\u00edt\u00e1si m\u00e9r\u00e9s<\/strong>: A m\u00e9r\u0151m\u0171szer m\u00e9ri a\u00a0<strong>elt\u00e9r\u00edt\u00e9s<\/strong>\u00a0a cs\u0151 \u00e1tm\u00e9r\u0151j\u00e9t \u00b10,01 mm-es pontoss\u00e1ggal, ami az anyag merevs\u00e9g\u00e9t jelzi.<\/li>\n<li><strong>Er\u0151 tartom\u00e1ny<\/strong>: A k\u00e9sz\u00fcl\u00e9k 1 N \u00e9s 60 N k\u00f6z\u00f6tti er\u0151vel k\u00e9pes cs\u00f6veket vizsg\u00e1lni, \u00edgy\u00a0<strong>sz\u00e9les v\u00e1laszt\u00e9k<\/strong>\u00a0a m\u00e9r\u00e9sek.<\/li>\n<\/ul>\n<p>A vizsg\u00e1lat eredm\u00e9nye k\u00f6zvetlen\u00fcl \u00f6sszef\u00fcgg a cs\u0151 merevs\u00e9g\u00e9vel, \u00e9s seg\u00edt a gy\u00e1rt\u00f3knak abban, hogy a term\u00e9k az elfogadhat\u00f3 tartom\u00e1nyon bel\u00fcl maradjon\u00a0<strong>biztons\u00e1g \u00e9s funkcionalit\u00e1s<\/strong>\u00a0az eg\u00e9szs\u00e9g\u00fcgyi k\u00f6rnyezetben.<\/p>\n<hr \/>\n<h2><strong>M\u0171szaki specifik\u00e1ci\u00f3k<\/strong><\/h2>\n<p>A TS-01 fecskend\u0151cs\u0151-merevs\u00e9gm\u00e9r\u0151 sz\u00e1mos\u00a0<strong>nagy pontoss\u00e1g\u00fa funkci\u00f3k<\/strong>\u00a0amelyek miatt elengedhetetlen eszk\u00f6zz\u00e9 v\u00e1lik az orvostechnikai eszk\u00f6z\u00f6k tesztel\u00e9s\u00e9ben. \u00cdme a legfontosabb m\u0171szaki adatok:<\/p>\n<ul>\n<li><strong>\u00c1lland\u00f3 er\u0151<\/strong>: 60 N (vagy be\u00e1ll\u00edthat\u00f3)<\/li>\n<li><strong>Teszt sebess\u00e9g<\/strong>: 1 \u00e9s 500 mm\/perc k\u00f6z\u00f6tt \u00e1ll\u00edthat\u00f3<\/li>\n<li><strong>Pontoss\u00e1g<\/strong>: \u00b10,01 mm az alakv\u00e1ltoz\u00e1s m\u00e9r\u00e9s\u00e9n\u00e9l<\/li>\n<li><strong>T\u00e1pegys\u00e9g<\/strong>: 110 V \u2013 220 V v\u00e1ltakoz\u00f3 \u00e1ram<\/li>\n<li><strong>Vez\u00e9rl\u0151rendszer<\/strong>: PLC-vez\u00e9rl\u00e9s\u0171,\u00a0<strong>7 h\u00fcvelykes HMI \u00e9rint\u0151k\u00e9perny\u0151<\/strong>\u00a0a k\u00f6nnyebb kezelhet\u0151s\u00e9g \u00e9rdek\u00e9ben<\/li>\n<li><strong>Tesztberendez\u00e9s<\/strong>: T\u00f6bbf\u00e9le r\u00f6gz\u00edt\u0151szerkezet \u00e1ll rendelkez\u00e9sre a lefel\u00e9 ir\u00e1nyul\u00f3 er\u0151vizsg\u00e1latokhoz<\/li>\n<li><strong>T\u00falterhel\u00e9s elleni v\u00e9delem<\/strong>: Be\u00e9p\u00edtett t\u00falterhel\u00e9s-v\u00e9delem a k\u00e9sz\u00fcl\u00e9k k\u00e1rosod\u00e1s\u00e1nak megel\u0151z\u00e9s\u00e9re<\/li>\n<li><strong>Mikronyomtat\u00f3<\/strong>: A vizsg\u00e1lati eredm\u00e9nyek azonnali kinyomtat\u00e1s\u00e1hoz<\/li>\n<\/ul>\n<p>Ezek\u00a0<strong>nagy pontoss\u00e1g\u00fa k\u00e9pess\u00e9gek<\/strong>\u00a0biztos\u00edtja, hogy a fecskend\u0151cs\u0151 merevs\u00e9g\u00e9t pontosan \u00e9s megb\u00edzhat\u00f3an m\u00e9rj\u00e9k, olyan eredm\u00e9nyeket szolg\u00e1ltatva, amelyekre a gy\u00e1rt\u00f3k \u00e9s a szab\u00e1lyoz\u00f3 hat\u00f3s\u00e1gok t\u00e1maszkodhatnak.<\/p>\n<hr \/>\n<h2><strong>El\u0151ny\u00f6k<\/strong><\/h2>\n<p>A TS-01 fecskend\u0151cs\u0151-merevs\u00e9gm\u00e9r\u0151 sz\u00e1mos el\u0151nnyel rendelkezik a hagyom\u00e1nyos merevs\u00e9gm\u00e9r\u00e9si m\u00f3dszerekkel szemben:<\/p>\n<ul>\n<li><strong>Nagy pontoss\u00e1g<\/strong>: A\u00a0<strong>\u00b10,01 mm<\/strong>\u00a0Az elt\u00e9r\u00edt\u00e9sm\u00e9r\u00e9s pontoss\u00e1ga rendk\u00edv\u00fcl megb\u00edzhat\u00f3 eredm\u00e9nyeket biztos\u00edt a kritikus alkalmaz\u00e1sokhoz.<\/li>\n<li><strong>Sz\u00e9les k\u00f6r\u0171 alkalmaz\u00e1si lehet\u0151s\u00e9gek<\/strong>: A TS-01 modell 60 N-ig \u00e1ll\u00edthat\u00f3 er\u0151vel \u00e9s v\u00e1ltoztathat\u00f3 vizsg\u00e1lati sebess\u00e9ggel rendelkezik, \u00edgy k\u00fcl\u00f6nf\u00e9le cs\u0151t\u00edpusokhoz \u00e9s vizsg\u00e1lati k\u00f6vetelm\u00e9nyekhez egyar\u00e1nt alkalmazhat\u00f3.<\/li>\n<li><strong>K\u00f6nny\u0171 haszn\u00e1lat<\/strong>: A\u00a0<strong>PLC-vez\u00e9rl\u0151rendszer<\/strong>\u00a0\u00e9s\u00a0<strong>\u00e9rint\u0151k\u00e9perny\u0151s kezel\u00e9s<\/strong>\u00a0egyszer\u0171s\u00edti a tesztel\u00e9si folyamatot, \u00edgy az m\u00e9g azok sz\u00e1m\u00e1ra is k\u00f6nnyen kezelhet\u0151v\u00e9 v\u00e1lik, akik nem rendelkeznek sz\u00e9lesk\u00f6r\u0171 m\u0171szaki ismeretekkel.<\/li>\n<li><strong>Tart\u00f3ss\u00e1g<\/strong>: A t\u00falterhel\u00e9s elleni v\u00e9delemnek \u00e9s az egyes tesztek ut\u00e1ni automatikus vissza\u00e1ll\u00edt\u00e1snak k\u00f6sz\u00f6nhet\u0151en a TS-01 m\u00e9g nagy volumen\u0171 tesztel\u00e9si k\u00f6rnyezetben is hossz\u00fa \u00e9lettartamot \u00e9s megb\u00edzhat\u00f3s\u00e1got garant\u00e1l.<\/li>\n<li><strong>A szabv\u00e1nyoknak val\u00f3 megfelel\u00e9s<\/strong>: A tesztel\u0151 k\u00e9sz\u00fcl\u00e9k \u00fagy lett kialak\u00edtva, hogy megfeleljen a\u00a0<strong>ISO 9626<\/strong>\u00a0\u00e9s\u00a0<strong>GB\/T 18457<\/strong>\u00a0szabv\u00e1nyoknak, biztos\u00edtva, hogy minden m\u00e9r\u00e9s megfeleljen a nemzetk\u00f6zi biztons\u00e1gi \u00e9s teljes\u00edtm\u00e9nyi el\u0151\u00edr\u00e1soknak.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Konfigur\u00e1ci\u00f3k \u00e9s tartoz\u00e9kok<\/strong><\/h2>\n<p>A\u00a0<strong>TS-01 fecskend\u0151cs\u0151 merevs\u00e9gm\u00e9r\u0151 TS-01<\/strong>\u00a0sz\u00e1mos alapkonfigur\u00e1ci\u00f3val \u00e9s opcion\u00e1lis kieg\u00e9sz\u00edt\u0151vel kaphat\u00f3, hogy megfeleljen a k\u00fcl\u00f6nb\u00f6z\u0151 tesztel\u00e9si ig\u00e9nyeknek:<\/p>\n<ul>\n<li><strong>F\u0151g\u00e9p<\/strong>: Egy mozgathat\u00f3 keresztfejb\u0151l \u00e9s a terhel\u00e9sm\u00e9r\u0151h\u00f6z csatlakoztatott tesztdugatty\u00fab\u00f3l \u00e1ll.<\/li>\n<li><strong>Tesztdugatty\u00fa<\/strong>: Prec\u00edzi\u00f3s dugatty\u00fa, amelynek hegy\u00e9n tompa \u00e9k tal\u00e1lhat\u00f3, \u00e9s amelynek feladata, hogy a cs\u0151re a megadott er\u0151t gyakorolja.<\/li>\n<li><strong>Teszted\u00e9ny<\/strong>: Egy tart\u00f3ed\u00e9ny, amely a vizsg\u00e1lat sor\u00e1n biztons\u00e1gosan r\u00f6gz\u00edti a cs\u00f6vet.<\/li>\n<li><strong>T\u00e1pk\u00e1bel \u00e9s biztos\u00edt\u00e9k<\/strong>: A m\u0171k\u00f6d\u00e9shez \u00e9s a biztons\u00e1ghoz elengedhetetlen.<\/li>\n<\/ul>\n<p>Tov\u00e1bbi kieg\u00e9sz\u00edt\u0151k, p\u00e9ld\u00e1ul\u00a0<strong>egyedi szerelv\u00e9nyek<\/strong>\u00a0k\u00fcl\u00f6nf\u00e9le tesztkonfigur\u00e1ci\u00f3khoz, a vizsg\u00e1lt cs\u0151vezet\u00e9k t\u00edpus\u00e1t\u00f3l f\u00fcgg\u0151en hozz\u00e1adhat\u00f3k.<\/p>\n<hr \/>\n<h2><strong>Szabv\u00e1nyok<\/strong><\/h2>\n<p>A\u00a0<strong>TS-01 fecskend\u0151cs\u0151 merevs\u00e9gm\u00e9r\u0151 TS-01<\/strong>\u00a0\u00fagy lett kialak\u00edtva, hogy megfeleljen\u00a0<strong>nemzetk\u00f6zi szabv\u00e1nyok<\/strong>\u00a0orvostechnikai eszk\u00f6z\u00f6k tesztel\u00e9se, ide\u00e9rtve:<\/p>\n<ul>\n<li><strong>ISO 9626<\/strong>: Meghat\u00e1rozza a t\u0171k gy\u00e1rt\u00e1s\u00e1hoz haszn\u00e1lt rozsdamentes ac\u00e9lcs\u00f6vek sz\u00fcks\u00e9ges mechanikai tulajdons\u00e1gait. A szabv\u00e1ny tartalmazza az ac\u00e9lcs\u00f6vek szil\u00e1rds\u00e1g\u00e1nak \u00e9s tart\u00f3ss\u00e1g\u00e1nak \u00e9rt\u00e9kel\u00e9s\u00e9re szolg\u00e1l\u00f3 m\u00f3dszereket, hogy biztos\u00edtsa a v\u00e9gterm\u00e9kre vonatkoz\u00f3 k\u00f6vetelm\u00e9nyek teljes\u00fcl\u00e9s\u00e9t. A sz\u00fcks\u00e9ges er\u0151 a t\u0171 vastags\u00e1g\u00e1t\u00f3l \u00e9s a falvastags\u00e1gt\u00f3l f\u00fcgg, melyek a t\u0171 rendeltet\u00e9s\u00e9t meghat\u00e1roz\u00f3 k\u00e9t t\u00e9nyez\u0151. A vizsg\u00e1latot h\u00e1rompontos hajl\u00edt\u00f3berendez\u00e9ssel v\u00e9gzik, hogy meghat\u00e1rozz\u00e1k az anyag merevs\u00e9g\u00e9t. Ezen fel\u00fcl konzolos hajl\u00edt\u00f3vizsg\u00e1latot is v\u00e9geznek, hogy \u00e9rt\u00e9kelj\u00e9k a cs\u0151 t\u00f6r\u00e9s\u00e1ll\u00f3s\u00e1g\u00e1t. Ez a vizsg\u00e1lat elengedhetetlen annak biztos\u00edt\u00e1s\u00e1hoz, hogy a t\u0171 ellen\u00e1lljon a klinikai k\u00f6rnyezetben el\u0151fordul\u00f3 ny\u00edr\u00f3er\u0151knek.<\/li>\n<li><strong>GB\/T 18457<\/strong>: Az orvosi eszk\u00f6z\u00f6k \u2013 t\u00f6bbek k\u00f6z\u00f6tt a fecskend\u0151k \u00e9s a cs\u00f6vek \u2013 vizsg\u00e1lat\u00e1ra vonatkoz\u00f3 k\u00ednai nemzeti szabv\u00e1nyok.<\/li>\n<\/ul>\n<p>Ezek a szabv\u00e1nyok garant\u00e1lj\u00e1k, hogy a TS-01 tesztel\u0151 k\u00e9sz\u00fcl\u00e9k megfeleljen a vil\u00e1gszerte elismert biztons\u00e1gi, min\u0151s\u00e9gi \u00e9s teljes\u00edtm\u00e9nyk\u00f6vetelm\u00e9nyeknek, \u00edgy ide\u00e1lis v\u00e1laszt\u00e1s szab\u00e1lyozott k\u00f6rnyezetben val\u00f3 haszn\u00e1latra.<\/p>\n<hr \/>\n<h2><strong>T\u00e1mogat\u00e1s \u00e9s k\u00e9pz\u00e9s<\/strong><\/h2>\n<p><a href=\"https:\/\/www.materialstests.com\/hu\/\"><strong>Cell Instruments<\/strong><\/a>\u00a0aj\u00e1nlatok\u00a0<strong>\u00e1tfog\u00f3 t\u00e1mogat\u00e1s<\/strong>\u00a0a\u00a0<strong>TS-01 fecskend\u0151cs\u0151 merevs\u00e9gm\u00e9r\u0151 TS-01<\/strong>, t\u00f6bbek k\u00f6z\u00f6tt:<\/p>\n<ul>\n<li><strong>Technikai t\u00e1mogat\u00e1s<\/strong>: Szak\u00e9rt\u0151i seg\u00edts\u00e9g ig\u00e9nybev\u00e9tele a hibaelh\u00e1r\u00edt\u00e1shoz \u00e9s a kalibr\u00e1l\u00e1shoz.<\/li>\n<li><strong>K\u00e9pz\u00e9s<\/strong>: A szem\u00e9lyzet sz\u00e1m\u00e1ra helysz\u00edni vagy online k\u00e9pz\u00e9s a g\u00e9p kezel\u00e9s\u00e9r\u0151l \u00e9s a vizsg\u00e1lati eredm\u00e9nyek \u00e9rtelmez\u00e9s\u00e9r\u0151l.<\/li>\n<li><strong>Szoftverfriss\u00edt\u00e9sek<\/strong>: A g\u00e9p szoftver\u00e9nek rendszeres friss\u00edt\u00e9se a funkcionalit\u00e1s jav\u00edt\u00e1sa \u00e9s a v\u00e1ltoz\u00f3 ipari szabv\u00e1nyoknak val\u00f3 megfelel\u00e9s biztos\u00edt\u00e1sa \u00e9rdek\u00e9ben.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Overview The\u00a0Syringe Tube Stiffness Tester\u00a0(TS-01)\u00a0is a high-precision testing device designed to measure the stiffness of medical tubing, particularly hypodermic needles and syringes. As\u00a0stiffness\u00a0directly impacts the safety, flexibility, and overall performance of medical tubing, accurate\u00a0stiffness testing\u00a0is essential to ensure that tubing maintains the right balance of mechanical strength and flexibility. Overly stiff tubing can increase the [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[],"standard-category":[],"class_list":["post-2774","products","type-products","status-publish","hentry","products-categories-medical-device-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/products\/2774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/products\/2774\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/media?parent=2774"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/products-categories?post=2774"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/productstags?post=2774"},{"taxonomy":"standard-category","embeddable":true,"href":"https:\/\/www.materialstests.com\/hu\/wp-json\/wp\/v2\/standard-category?post=2774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}