{"id":2774,"date":"2026-02-05T01:34:48","date_gmt":"2026-02-05T01:34:48","guid":{"rendered":"https:\/\/www.materialstests.com\/products\/ts-01-syringe-tube-stiffness-tester\/"},"modified":"2026-02-05T01:34:48","modified_gmt":"2026-02-05T01:34:48","slug":"ts-01-syringe-tube-stiffness-tester","status":"publish","type":"products","link":"https:\/\/www.materialstests.com\/cs\/products\/ts-01-syringe-tube-stiffness-tester.html","title":{"rendered":"TS-01 Tester tuhosti st\u0159\u00edka\u010dkov\u00e9 trubice"},"content":{"rendered":"<h2><strong>P\u0159ehled<\/strong><\/h2>\n<p>Na str\u00e1nk\u00e1ch\u00a0<strong><a href=\"https:\/\/www.materialstests.com\/cs\/medical-device-tester.html\/\">Tester tuhosti injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/a>\u00a0(TS-01)<\/strong>\u00a0je vysoce p\u0159esn\u00e9 testovac\u00ed za\u0159\u00edzen\u00ed ur\u010den\u00e9 k m\u011b\u0159en\u00ed tuhosti l\u00e9ka\u0159sk\u00fdch hadi\u010dek, zejm\u00e9na injek\u010dn\u00edch jehel a st\u0159\u00edka\u010dek. Jako\u00a0<strong>tuhost<\/strong>\u00a0p\u0159\u00edmo ovliv\u0148uje bezpe\u010dnost, flexibilitu a celkov\u00fd v\u00fdkon l\u00e9ka\u0159sk\u00fdch hadi\u010dek, p\u0159esn\u00fd\u00a0<strong>zkou\u0161ka tuhosti<\/strong>\u00a0je nezbytn\u00e9 zajistit, aby si trubky zachovaly spr\u00e1vnou rovnov\u00e1hu mechanick\u00e9 pevnosti a pru\u017enosti. P\u0159\u00edli\u0161 tuh\u00e9 hadi\u010dky mohou zv\u00fd\u0161it riziko zlomen\u00ed nebo k\u0159ehk\u00fdch zlomenin, zat\u00edmco p\u0159\u00edli\u0161 m\u011bkk\u00e9 hadi\u010dky mohou v\u00e9st k oh\u00fdb\u00e1n\u00ed, po\u0161kozen\u00ed a potenci\u00e1ln\u011b nebezpe\u010dn\u00fdm l\u00e9ka\u0159sk\u00fdm postup\u016fm.<\/p>\n<p>Na str\u00e1nk\u00e1ch\u00a0<strong>Tester tuhosti l\u00e9ka\u0159sk\u00e9 jehly<\/strong>\u00a0je navr\u017een tak, aby simuloval skute\u010dn\u00e9 podm\u00ednky p\u016fsoben\u00edm ur\u010dit\u00e9 s\u00edly na st\u0159ed trubky a m\u011b\u0159en\u00edm jej\u00edho pr\u016fhybu. T\u00edm je zaji\u0161t\u011bno, \u017ee hadi\u010dky maj\u00ed pot\u0159ebnou tuhost, aby bezpe\u010dn\u011b fungovaly p\u0159i l\u00e9ka\u0159sk\u00fdch aplikac\u00edch, jako jsou injekce, infuze a dal\u0161\u00ed kritick\u00e9 postupy.<\/p>\n<hr \/>\n<h2><strong>Aplikace<\/strong><\/h2>\n<p>Tester tuhosti st\u0159\u00edka\u010dek TS-01 je hojn\u011b vyu\u017e\u00edv\u00e1n v oblasti\u00a0<strong>l\u00e9ka\u0159sk\u00fd, farmaceutick\u00fd a obalov\u00fd pr\u016fmysl<\/strong>\u00a0kde je p\u0159esn\u00e1 kontrola vlastnost\u00ed trubek nezbytn\u00e1 pro bezpe\u010dnost v\u00fdrobk\u016f. Mezi jeho hlavn\u00ed aplikace pat\u0159\u00ed:<\/p>\n<ul>\n<li><strong>V\u00fdroba st\u0159\u00edka\u010dek<\/strong>: Zaji\u0161t\u011bn\u00ed po\u017eadovan\u00e9 tuhosti injek\u010dn\u00edch st\u0159\u00edka\u010dek, injek\u010dn\u00edch jehel a kat\u00e9tr\u016f, aby se minimalizovalo riziko p\u0159i zav\u00e1d\u011bn\u00ed a operaci.<\/li>\n<li><strong>V\u00fdzkum a v\u00fdvoj zdravotnick\u00fdch prost\u0159edk\u016f<\/strong>: Testov\u00e1n\u00ed nov\u00fdch konstrukc\u00ed a materi\u00e1l\u016f pou\u017e\u00edvan\u00fdch ve zdravotnick\u00fdch hadi\u010dk\u00e1ch, aby byly v souladu s mezin\u00e1rodn\u00edmi bezpe\u010dnostn\u00edmi normami, nap\u0159.\u00a0<strong>ISO 9626<\/strong>.<\/li>\n<li><strong>Kontrola kvality<\/strong>: Rutinn\u00ed testov\u00e1n\u00ed zdravotnick\u00fdch obalov\u00fdch materi\u00e1l\u016f, jako jsou flexibiln\u00ed zkumavky a injek\u010dn\u00ed m\u00edsta, aby se zajistilo, \u017ee spl\u0148uj\u00ed regula\u010dn\u00ed po\u017eadavky a funguj\u00ed b\u011bhem klinick\u00e9ho pou\u017eit\u00ed tak, jak maj\u00ed.<\/li>\n<li><strong>Zdravotnick\u00e9 obaly<\/strong>: Ov\u011b\u0159en\u00ed, zda trubi\u010dky pou\u017e\u00edvan\u00e9 ve zdravotnick\u00fdch obalech nejsou p\u0159\u00edli\u0161 tuh\u00e9 (co\u017e m\u016f\u017ee zp\u016fsobit jejich k\u0159ehkost) ani p\u0159\u00edli\u0161 m\u011bkk\u00e9 (co\u017e m\u016f\u017ee zp\u016fsobit probl\u00e9my s pru\u017enost\u00ed p\u0159i pou\u017e\u00edv\u00e1n\u00ed).<\/li>\n<li><strong>Farmaceutick\u00fd pr\u016fmysl<\/strong>: Zaji\u0161t\u011bn\u00ed bezpe\u010dnosti a spolehlivosti syst\u00e9mu pod\u00e1v\u00e1n\u00ed l\u00e9k\u016f testov\u00e1n\u00edm hadi\u010dek pou\u017e\u00edvan\u00fdch v injek\u010dn\u00edch st\u0159\u00edka\u010dk\u00e1ch a infuzn\u00edch souprav\u00e1ch.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Nezbytnost<\/strong><\/h2>\n<p>Ve zdravotnictv\u00ed,\u00a0<strong>tuhost trubek<\/strong>\u00a0nen\u00ed jen vlastnost\u00ed kvality - je to\u00a0<strong>kritick\u00fd bezpe\u010dnostn\u00ed faktor<\/strong>. Tuhost injek\u010dn\u00ed st\u0159\u00edka\u010dky nebo injek\u010dn\u00ed jehly ovliv\u0148uje jej\u00ed celkov\u00fd v\u00fdkon.\u00a0<strong>nespr\u00e1vn\u00e1 tuhost<\/strong>\u00a0m\u016f\u017ee v\u00e9st k r\u016fzn\u00fdm provozn\u00edm probl\u00e9m\u016fm, jako jsou pot\u00ed\u017ee p\u0159i zav\u00e1d\u011bn\u00ed, zlomen\u00ed nebo nespr\u00e1vn\u00e1 funkce b\u011bhem l\u00e9ka\u0159sk\u00fdch z\u00e1krok\u016f. P\u0159\u00edli\u0161 tuh\u00e9 hadi\u010dky mohou p\u0159i nam\u00e1h\u00e1n\u00ed zk\u0159ehnout a selhat, co\u017e m\u016f\u017ee v\u00e9st ke katastrof\u00e1ln\u00edmu selh\u00e1n\u00ed b\u011bhem z\u00e1kroku.<\/p>\n<p>Naopak p\u0159\u00edli\u0161 pru\u017en\u00e9 nebo m\u011bkk\u00e9 hadi\u010dky mohou v\u00e9st k oh\u00fdb\u00e1n\u00ed, zalamov\u00e1n\u00ed nebo deformaci, co\u017e m\u016f\u017ee zp\u016fsobit chyby p\u0159i l\u00e9ka\u0159sk\u00fdch z\u00e1kroc\u00edch nebo dokonce ohrozit sterilitu. Tester tuhosti st\u0159\u00edka\u010dkov\u00fdch hadi\u010dek je z\u00e1kladn\u00edm n\u00e1strojem, kter\u00fd umo\u017e\u0148uje\u00a0<strong>m\u011b\u0159it a ov\u011b\u0159ovat<\/strong>\u00a0\u017ee hadi\u010dky pou\u017e\u00edvan\u00e9 v t\u011bchto za\u0159\u00edzen\u00edch jsou optimalizov\u00e1ny z hlediska bezpe\u010dnosti, pru\u017enosti a pevnosti.<\/p>\n<hr \/>\n<h2><strong>Princip fungov\u00e1n\u00ed<\/strong><\/h2>\n<p>TS-01\u00a0<strong>Tester tuhosti injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/strong>\u00a0funguje na jednoduch\u00e9m, ale velmi \u00fa\u010dinn\u00e9m principu. P\u0159i zkou\u0161ce se na st\u0159ed trubky, kter\u00e1 je na obou konc\u00edch podep\u0159ena, p\u016fsob\u00ed ur\u010ditou silou (a\u017e 60 N). Zkou\u0161e\u010dka m\u011b\u0159\u00ed\u00a0<strong>vych\u00fdlen\u00ed<\/strong>\u00a0trubky v reakci na p\u016fsob\u00edc\u00ed s\u00edlu.<\/p>\n<h4>Kl\u00ed\u010dov\u00e9 vlastnosti:<\/h4>\n<ul>\n<li><strong>Aplikace s\u00edly<\/strong>: Tup\u00fd p\u00edst ve tvaru kl\u00ednu, sklon\u011bn\u00fd pod \u00fahlem 60\u00b0 a s polom\u011brem v\u00e1lce 1 mm, p\u016fsob\u00ed na hadi\u010dku \u0159\u00edzenou silou sm\u011brem dol\u016f.<\/li>\n<li><strong>M\u011b\u0159en\u00ed pr\u016fhybu<\/strong>: Tester m\u011b\u0159\u00ed\u00a0<strong>vych\u00fdlen\u00ed<\/strong>\u00a0trubky s p\u0159esnost\u00ed \u00b10,01 mm, co\u017e je \u00fadaj o tuhosti materi\u00e1lu.<\/li>\n<li><strong>Rozsah s\u00edly<\/strong>: P\u0159\u00edstroj je schopen testovat trubky silou od 1 N do 60 N, co\u017e poskytuje\u00a0<strong>v\u0161estrann\u00fd sortiment<\/strong>\u00a0m\u011b\u0159en\u00ed.<\/li>\n<\/ul>\n<p>V\u00fdsledek t\u00e9to zkou\u0161ky p\u0159\u00edmo souvis\u00ed s tuhost\u00ed trubek a pom\u00e1h\u00e1 v\u00fdrobc\u016fm zajistit, aby byl v\u00fdrobek v p\u0159ijateln\u00e9m rozmez\u00ed.\u00a0<strong>bezpe\u010dnost a funk\u010dnost<\/strong>\u00a0ve zdravotnick\u00e9m prost\u0159ed\u00ed.<\/p>\n<hr \/>\n<h2><strong>Technick\u00e9 specifikace<\/strong><\/h2>\n<p>Tester tuhosti st\u0159\u00edka\u010dkov\u00fdch hadi\u010dek TS-01 se m\u016f\u017ee pochlubit rozsahem\u00a0<strong>vysoce p\u0159esn\u00e9 funkce<\/strong>\u00a0kter\u00e9 z n\u011bj \u010din\u00ed nepostradateln\u00fd n\u00e1stroj pro testov\u00e1n\u00ed zdravotnick\u00fdch prost\u0159edk\u016f. Zde jsou kl\u00ed\u010dov\u00e9 specifikace:<\/p>\n<ul>\n<li><strong>Pevn\u00e1 s\u00edla<\/strong>: 60 N (nebo p\u0159izp\u016fsobiteln\u00e9)<\/li>\n<li><strong>Testovac\u00ed rychlost<\/strong>: Nastaviteln\u00fd v rozmez\u00ed 1 a\u017e 500 mm\/min<\/li>\n<li><strong>P\u0159esnost<\/strong>: \u00b10,01 mm p\u0159i m\u011b\u0159en\u00ed pr\u016fhybu<\/li>\n<li><strong>Nap\u00e1jen\u00ed<\/strong>: 110V a\u017e 220V AC<\/li>\n<li><strong>\u0158\u00eddic\u00ed syst\u00e9m<\/strong>: \u0159\u00edzen\u00fd PLC s\u00a0<strong>7palcov\u00e1 dotykov\u00e1 obrazovka HMI<\/strong>\u00a0pro snadn\u00e9 ovl\u00e1d\u00e1n\u00ed<\/li>\n<li><strong>Testovac\u00ed za\u0159\u00edzen\u00ed<\/strong>: K dispozici je v\u00edce p\u0159\u00edpravk\u016f pro testy s\u00edly sm\u011brem dol\u016f<\/li>\n<li><strong>Ochrana proti p\u0159et\u00ed\u017een\u00ed<\/strong>: Vestav\u011bn\u00e1 ochrana proti p\u0159et\u00ed\u017een\u00ed, kter\u00e1 zabra\u0148uje po\u0161kozen\u00ed za\u0159\u00edzen\u00ed<\/li>\n<li><strong>Mikrotisk\u00e1rna<\/strong>: Pro okam\u017eit\u00fd tisk v\u00fdsledk\u016f test\u016f<\/li>\n<\/ul>\n<p>Tyto str\u00e1nky\u00a0<strong>vysoce p\u0159esn\u00e9 funkce<\/strong>\u00a0zaji\u0161\u0165uj\u00ed p\u0159esn\u00e9 a spolehliv\u00e9 m\u011b\u0159en\u00ed tuhosti injek\u010dn\u00edch hadi\u010dek a poskytuj\u00ed v\u00fdsledky, kter\u00fdm mohou v\u00fdrobci a regula\u010dn\u00ed org\u00e1ny d\u016fv\u011b\u0159ovat.<\/p>\n<hr \/>\n<h2><strong>V\u00fdhody<\/strong><\/h2>\n<p>Tester tuhosti trubek TS-01 nab\u00edz\u00ed oproti tradi\u010dn\u00edm metod\u00e1m zkou\u0161en\u00ed tuhosti n\u011bkolik v\u00fdhod:<\/p>\n<ul>\n<li><strong>Vysok\u00e1 p\u0159esnost<\/strong>: Na\u00a0<strong>\u00b10,01 mm<\/strong>\u00a0p\u0159esnost m\u011b\u0159en\u00ed pr\u016fhybu zaji\u0161\u0165uje vysoce spolehliv\u00e9 v\u00fdsledky pro kritick\u00e9 aplikace.<\/li>\n<li><strong>\u0160irok\u00fd rozsah pou\u017eit\u00ed<\/strong>: D\u00edky nastaviteln\u00e9 s\u00edle a\u017e 60 N a prom\u011bnliv\u00e9 rychlosti zkou\u0161en\u00ed je TS-01 p\u0159izp\u016fsobiteln\u00fd r\u016fzn\u00fdm typ\u016fm trubek a po\u017eadavk\u016fm na zkou\u0161en\u00ed.<\/li>\n<li><strong>Snadn\u00e9 pou\u017e\u00edv\u00e1n\u00ed<\/strong>: Na\u00a0<strong>\u0158\u00eddic\u00ed syst\u00e9m PLC<\/strong>\u00a0a\u00a0<strong>ovl\u00e1d\u00e1n\u00ed dotykov\u00e9 obrazovky<\/strong>\u00a0zjednodu\u0161it proces testov\u00e1n\u00ed, aby byl u\u017eivatelsky p\u0159\u00edv\u011btiv\u00fd i pro ty, kte\u0159\u00ed nemaj\u00ed rozs\u00e1hl\u00e9 technick\u00e9 znalosti.<\/li>\n<li><strong>Odolnost<\/strong>: D\u00edky ochran\u011b proti p\u0159et\u00ed\u017een\u00ed a automatick\u00e9mu n\u00e1vratu po ka\u017ed\u00e9m testu zaji\u0161\u0165uje TS-01 dlouhou \u017eivotnost a spolehlivost i v prost\u0159ed\u00ed s velk\u00fdm objemem test\u016f.<\/li>\n<li><strong>Soulad s normami<\/strong>: Tester je navr\u017een tak, aby vyhovoval\u00a0<strong>ISO 9626<\/strong>\u00a0a\u00a0<strong>GB\/T18457<\/strong>\u00a0normy a zaji\u0161\u0165uje, aby v\u0161echna m\u011b\u0159en\u00ed spl\u0148ovala mezin\u00e1rodn\u00ed bezpe\u010dnostn\u00ed a v\u00fdkonnostn\u00ed sm\u011brnice.<\/li>\n<\/ul>\n<hr \/>\n<h2><strong>Konfigurace a p\u0159\u00edslu\u0161enstv\u00ed<\/strong><\/h2>\n<p>Na str\u00e1nk\u00e1ch\u00a0<strong>TS-01 Tester tuhosti st\u0159\u00edka\u010dkov\u00e9 trubice<\/strong>\u00a0se dod\u00e1v\u00e1 s n\u011bkolika standardn\u00edmi konfiguracemi a voliteln\u00fdm p\u0159\u00edslu\u0161enstv\u00edm, kter\u00e9 vyhovuje r\u016fzn\u00fdm pot\u0159eb\u00e1m testov\u00e1n\u00ed:<\/p>\n<ul>\n<li><strong>Hlavn\u00ed stroj<\/strong>: Skl\u00e1d\u00e1 se z pohybliv\u00e9 p\u0159\u00ed\u010dn\u00e9 hlavy a zku\u0161ebn\u00edho p\u00edstu p\u0159ipojen\u00e9ho k silom\u011bru.<\/li>\n<li><strong>Zku\u0161ebn\u00ed p\u00edst<\/strong>: P\u0159esn\u00fd p\u00edst s tup\u00fdm kl\u00ednem na \u0161pi\u010dce, kter\u00fd je ur\u010den k p\u016fsoben\u00ed specifikovan\u00e9 s\u00edly na hadi\u010dku.<\/li>\n<li><strong>Testovac\u00ed p\u00e1nev<\/strong>: P\u00e1nev pro bezpe\u010dn\u00e9 uchycen\u00ed trubek b\u011bhem testov\u00e1n\u00ed.<\/li>\n<li><strong>Nap\u00e1jec\u00ed kabel a pojistka<\/strong>: Nezbytn\u00e9 pro provoz a bezpe\u010dnost.<\/li>\n<\/ul>\n<p>Dal\u0161\u00ed p\u0159\u00edslu\u0161enstv\u00ed, nap\u0159.\u00a0<strong>p\u0159izp\u016fsoben\u00e1 sv\u00edtidla<\/strong>\u00a0pro r\u016fzn\u00e9 zku\u0161ebn\u00ed konfigurace, lze p\u0159idat v z\u00e1vislosti na testovan\u00e9 trubce.<\/p>\n<hr \/>\n<h2><strong>Normy<\/strong><\/h2>\n<p>Na str\u00e1nk\u00e1ch\u00a0<strong>TS-01 Tester tuhosti st\u0159\u00edka\u010dkov\u00e9 trubice<\/strong>\u00a0je navr\u017een tak, aby spl\u0148oval\u00a0<strong>mezin\u00e1rodn\u00ed normy<\/strong>\u00a0pro testov\u00e1n\u00ed zdravotnick\u00fdch prost\u0159edk\u016f, v\u010detn\u011b:<\/p>\n<ul>\n<li><strong>ISO 9626<\/strong>: Definuje po\u017eadovan\u00e9 mechanick\u00e9 vlastnosti trubek z nerezov\u00e9 oceli pou\u017e\u00edvan\u00fdch k v\u00fdrob\u011b jehel. Norma zahrnuje metody hodnocen\u00ed pevnosti a trvanlivosti ocelov\u00fdch trubek, aby se zajistilo, \u017ee spl\u0148uj\u00ed po\u017eadavky na kone\u010dn\u00fd v\u00fdrobek. Po\u017eadovan\u00e1 s\u00edla z\u00e1vis\u00ed na rozm\u011bru jehly a tlou\u0161\u0165ce st\u011bny, co\u017e jsou dva faktory, kter\u00e9 ur\u010duj\u00ed \u00fa\u010del jehly. Zkou\u0161ky se prov\u00e1d\u011bj\u00ed pomoc\u00ed sestavy t\u0159\u00edbodov\u00e9ho ohybu, aby se zjistila tuhost materi\u00e1lu. Krom\u011b toho se prov\u00e1d\u00ed zkou\u0161ka konzolov\u00fdm ohybem, aby se vyhodnotila schopnost trubek odol\u00e1vat lomu. Tato zkou\u0161ka je rozhoduj\u00edc\u00ed pro zaji\u0161t\u011bn\u00ed toho, aby jehla odolala smykov\u00fdm sil\u00e1m, kter\u00e9 se mohou vyskytnout v klinick\u00e9m prost\u0159ed\u00ed.<\/li>\n<li><strong>GB\/T18457<\/strong>: \u010c\u00ednsk\u00e9 n\u00e1rodn\u00ed normy pro zkou\u0161en\u00ed zdravotnick\u00fdch prost\u0159edk\u016f, v\u010detn\u011b injek\u010dn\u00edch st\u0159\u00edka\u010dek a hadi\u010dek.<\/li>\n<\/ul>\n<p>Tyto normy zaji\u0161\u0165uj\u00ed, \u017ee tester TS-01 spl\u0148uje celosv\u011btov\u011b uzn\u00e1van\u00e9 po\u017eadavky na bezpe\u010dnost, kvalitu a v\u00fdkon, tak\u017ee je ide\u00e1ln\u00ed pro pou\u017eit\u00ed v regulovan\u00fdch prost\u0159ed\u00edch.<\/p>\n<hr \/>\n<h2><strong>Podpora a \u0161kolen\u00ed<\/strong><\/h2>\n<p><a href=\"https:\/\/www.materialstests.com\/cs\/\"><strong>Cell Instruments<\/strong><\/a>\u00a0nab\u00edz\u00ed\u00a0<strong>komplexn\u00ed podpora<\/strong>\u00a0pro\u00a0<strong>TS-01 Tester tuhosti st\u0159\u00edka\u010dkov\u00e9 trubice<\/strong>, v\u010detn\u011b:<\/p>\n<ul>\n<li><strong>Technick\u00e1 podpora<\/strong>: P\u0159\u00edstup k odborn\u00e9 pomoci p\u0159i \u0159e\u0161en\u00ed probl\u00e9m\u016f a kalibraci.<\/li>\n<li><strong>\u0160kolen\u00ed<\/strong>: \u0160kolen\u00ed zam\u011bstnanc\u016f na m\u00edst\u011b nebo online o obsluze p\u0159\u00edstroje a interpretaci v\u00fdsledk\u016f test\u016f.<\/li>\n<li><strong>Aktualizace softwaru<\/strong>: Pravideln\u00e9 aktualizace softwaru stroje pro zlep\u0161en\u00ed funk\u010dnosti a zaji\u0161t\u011bn\u00ed souladu s m\u011bn\u00edc\u00edmi se pr\u016fmyslov\u00fdmi normami.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Overview The\u00a0Syringe Tube Stiffness Tester\u00a0(TS-01)\u00a0is a high-precision testing device designed to measure the stiffness of medical tubing, particularly hypodermic needles and syringes. As\u00a0stiffness\u00a0directly impacts the safety, flexibility, and overall performance of medical tubing, accurate\u00a0stiffness testing\u00a0is essential to ensure that tubing maintains the right balance of mechanical strength and flexibility. Overly stiff tubing can increase the [&hellip;]<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"products-categories":[1301],"productstags":[],"class_list":["post-2774","products","type-products","status-publish","hentry","products-categories-medical-device-tester"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/products\/2774","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/products\/2774\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/media?parent=2774"}],"wp:term":[{"taxonomy":"products-categories","embeddable":true,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/products-categories?post=2774"},{"taxonomy":"productstags","embeddable":true,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/productstags?post=2774"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}