{"id":1060,"date":"2025-12-12T01:08:07","date_gmt":"2025-12-12T01:08:07","guid":{"rendered":"https:\/\/www.materialstests.com\/?p=1060"},"modified":"2025-12-12T01:08:10","modified_gmt":"2025-12-12T01:08:10","slug":"understanding-the-syringe-break-loose-force-test-key-to-quality-and-safety-in-medical-devices","status":"publish","type":"post","link":"https:\/\/www.materialstests.com\/cs\/news\/understanding-the-syringe-break-loose-force-test-key-to-quality-and-safety-in-medical-devices.html","title":{"rendered":"Porozum\u011bn\u00ed zkou\u0161ce s\u00edly uvoln\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky: kl\u00ed\u010d k kvalit\u011b a bezpe\u010dnosti zdravotnick\u00fdch prost\u0159edk\u016f"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Zkou\u0161ka s\u00edly pot\u0159ebn\u00e9 k uvoln\u011bn\u00ed p\u00edstu v injek\u010dn\u00ed st\u0159\u00edka\u010dce hraje kl\u00ed\u010dovou roli p\u0159i hodnocen\u00ed v\u00fdkonu a kvality injek\u010dn\u00edch st\u0159\u00edka\u010dek pou\u017e\u00edvan\u00fdch v l\u00e9ka\u0159sk\u00fdch a farmaceutick\u00fdch aplikac\u00edch. Tato zkou\u0161ka ur\u010duje s\u00edlu pot\u0159ebnou k zah\u00e1jen\u00ed pohybu p\u00edstu v injek\u010dn\u00ed st\u0159\u00edka\u010dce a zaji\u0161\u0165uje, \u017ee injek\u010dn\u00ed st\u0159\u00edka\u010dky spl\u0148uj\u00ed p\u0159\u00edsn\u00e9 normy pou\u017eitelnosti a bezpe\u010dnosti. V tomto \u010dl\u00e1nku se podrobn\u011bji zam\u011b\u0159\u00edme na specifika zkou\u0161ky odtrhov\u00e9 s\u00edly, prozkoum\u00e1me p\u0159\u00edslu\u0161n\u00e9 normy ISO a p\u0159edstav\u00edme tester injek\u010dn\u00edch st\u0159\u00edka\u010dek MST-01 pro p\u0159esn\u00e9 a efektivn\u00ed testov\u00e1n\u00ed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Co je to zkou\u0161ka s\u00edly pot\u0159ebn\u00e9 k uvoln\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Zkou\u0161ka odtrhov\u00e9 s\u00edly injek\u010dn\u00ed st\u0159\u00edka\u010dky m\u011b\u0159\u00ed s\u00edlu pot\u0159ebnou k posunut\u00ed p\u00edstu uvnit\u0159 injek\u010dn\u00ed st\u0159\u00edka\u010dky. Tato zkou\u0161ka je z\u00e1sadn\u00ed pro zaji\u0161t\u011bn\u00ed toho, aby injek\u010dn\u00ed st\u0159\u00edka\u010dka fungovala podle sv\u00e9ho ur\u010den\u00ed a aby u\u017eivatel mohl snadno zah\u00e1jit pr\u016ftok tekutiny, co\u017e je p\u0159i l\u00e9ka\u0159sk\u00fdch z\u00e1kroc\u00edch nezbytn\u00e9.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Understanding-the-Syringe-Break-Loose-Force-Test-Key-to-Quality-and-Safety-in-Medical-Devices-1024x576.jpg\" alt=\"Porozum\u011bn\u00ed zkou\u0161ce s\u00edly uvoln\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky: kl\u00ed\u010d k kvalit\u011b a bezpe\u010dnosti zdravotnick\u00fdch prost\u0159edk\u016f\" class=\"wp-image-1062\" title=\"Porozum\u011bn\u00ed zkou\u0161ce s\u00edly uvoln\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky: kl\u00ed\u010d k kvalit\u011b a bezpe\u010dnosti zdravotnick\u00fdch prost\u0159edk\u016f\" srcset=\"https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Understanding-the-Syringe-Break-Loose-Force-Test-Key-to-Quality-and-Safety-in-Medical-Devices-1024x576.jpg 1024w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Understanding-the-Syringe-Break-Loose-Force-Test-Key-to-Quality-and-Safety-in-Medical-Devices-300x169.jpg 300w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Understanding-the-Syringe-Break-Loose-Force-Test-Key-to-Quality-and-Safety-in-Medical-Devices-768x432.jpg 768w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Understanding-the-Syringe-Break-Loose-Force-Test-Key-to-Quality-and-Safety-in-Medical-Devices-1536x864.jpg 1536w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Understanding-the-Syringe-Break-Loose-Force-Test-Key-to-Quality-and-Safety-in-Medical-Devices-600x338.jpg 600w, https:\/\/www.materialstests.com\/wp-content\/uploads\/2025\/12\/Understanding-the-Syringe-Break-Loose-Force-Test-Key-to-Quality-and-Safety-in-Medical-Devices.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Zkou\u0161ka za\u010d\u00edn\u00e1 napln\u011bn\u00edm injek\u010dn\u00ed st\u0159\u00edka\u010dky stanoven\u00fdm objemem kapaliny (obvykle destilovan\u00e9 vody) a upnut\u00edm st\u0159\u00edka\u010dky do zku\u0161ebn\u00edho za\u0159\u00edzen\u00ed. Na injek\u010dn\u00ed st\u0159\u00edka\u010dku se pot\u00e9 p\u016fsob\u00ed postupn\u011b se zvy\u0161uj\u00edc\u00ed silou, dokud se p\u00edst nepohne, \u010d\u00edm\u017e se ur\u010d\u00ed bod \u201cuvoln\u011bn\u00ed\u201d. S\u00edla pot\u0159ebn\u00e1 k posunut\u00ed p\u00edstu se zaznamen\u00e1, obvykle v newtonech, aby se ov\u011b\u0159ilo, zda spad\u00e1 do p\u0159\u00edpustn\u00e9ho rozsahu stanoven\u00e9ho p\u0159\u00edslu\u0161n\u00fdmi normami, jako je nap\u0159\u00edklad ISO 8537.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pro\u010d je zkou\u0161ka s\u00edly uvoln\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky d\u016fle\u017eit\u00e1?<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Pou\u017eitelnost<\/strong>: St\u0159\u00edka\u010dka s p\u0159\u00edli\u0161 vysokou odtrhovou silou m\u016f\u017ee b\u00fdt pro zdravotnick\u00fd person\u00e1l obt\u00ed\u017en\u011b pou\u017eiteln\u00e1, zat\u00edmco p\u0159\u00edli\u0161 n\u00edzk\u00e1 s\u00edla by mohla v\u00e9st k p\u0159ed\u010dasn\u00e9mu pohybu p\u00edstu, co\u017e by ovlivnilo p\u0159esnost pod\u00e1n\u00ed l\u00e9ku.<\/li>\n\n\n\n<li><strong>Zaji\u0161t\u011bn\u00ed kvality<\/strong>: Tato zkou\u0161ka zaji\u0161\u0165uje, \u017ee injek\u010dn\u00ed st\u0159\u00edka\u010dky jsou vyr\u00e1b\u011bny v souladu se spr\u00e1vn\u00fdmi specifikacemi a spl\u0148uj\u00ed bezpe\u010dnostn\u00ed normy pro zdravotnick\u00e9 prost\u0159edky, jako jsou USP 382 a ISO 8537.<\/li>\n\n\n\n<li><strong>Dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f<\/strong>: Dodr\u017eov\u00e1n\u00edm norem ISO mohou v\u00fdrobci zajistit, \u017ee jejich injek\u010dn\u00ed st\u0159\u00edka\u010dky spl\u0148uj\u00ed celosv\u011btov\u00e9 regula\u010dn\u00ed po\u017eadavky, \u010d\u00edm\u017e p\u0159isp\u00edvaj\u00ed k bezpe\u010dnosti v\u00fdrobk\u016f a posiluj\u00ed d\u016fv\u011bru v n\u011b.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Zkou\u0161ka kluzn\u00e9 s\u00edly u injek\u010dn\u00edch st\u0159\u00edka\u010dek: norma ISO 8537<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Krom\u011b zkou\u0161ky odtrhov\u00e9 s\u00edly p\u0159edstavuje zkou\u0161ka kluzn\u00e9 s\u00edly dal\u0161\u00ed kl\u00ed\u010dov\u00fd test, kter\u00fd m\u011b\u0159\u00ed odpor proti pohybu p\u00edstu po zah\u00e1jen\u00ed pohybu p\u00edstu. Kluzn\u00e1 s\u00edla zaji\u0161\u0165uje plynul\u00fd chod b\u011bhem injek\u010dn\u00edho procesu a je obzvl\u00e1\u0161t\u011b d\u016fle\u017eit\u00e1 u injek\u010dn\u00edch st\u0159\u00edka\u010dek pou\u017e\u00edvan\u00fdch p\u0159i l\u00e9ka\u0159sk\u00fdch injekc\u00edch a o\u010dkov\u00e1n\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Podle&nbsp;<strong>ISO 8537<\/strong>, kter\u00e1 stanovuje zku\u0161ebn\u00ed metody pro p\u0159edpln\u011bn\u00e9 injek\u010dn\u00ed st\u0159\u00edka\u010dky, je zkou\u0161ka kluzn\u00e9 s\u00edly kl\u00ed\u010dov\u00e1 pro posouzen\u00ed funk\u010dnosti p\u00edstu po jeho po\u010d\u00e1te\u010dn\u00edm pohybu. Tato zkou\u0161ka zaji\u0161\u0165uje, \u017ee p\u00edst lze pohybovat plynule a rovnom\u011brn\u011b bez nadm\u011brn\u00e9ho odporu. Dodr\u017een\u00ed normy ISO 8537 zaru\u010duje funk\u010dnost, spolehlivost a celkovou bezpe\u010dnost injek\u010dn\u00ed st\u0159\u00edka\u010dky v l\u00e9ka\u0159sk\u00e9m prost\u0159ed\u00ed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Zku\u0161ebn\u00ed metoda pro stanoven\u00ed s\u00edly pot\u0159ebn\u00e9 k uvoln\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Nastaven\u00ed<\/strong>: St\u0159\u00edka\u010dka je pevn\u011b upnuta na zku\u0161ebn\u00edm stroji tak, \u017ee jej\u00ed jehla sm\u011b\u0159uje dol\u016f.<\/li>\n\n\n\n<li><strong>N\u00e1pl\u0148<\/strong>: St\u0159\u00edka\u010dka se napln\u00ed destilovanou vodou do \u00farovn\u011b 50% jej\u00ed jmenovit\u00e9 kapacity, aby se simuloval pohyb tekutiny b\u011bhem injekce.<\/li>\n\n\n\n<li><strong>Aplikace s\u00edly<\/strong>: Na p\u00edst injek\u010dn\u00ed st\u0159\u00edka\u010dky se postupn\u011b p\u016fsob\u00ed svislou silou. S\u00edla se nep\u0159etr\u017eit\u011b m\u011b\u0159\u00ed silom\u011brem, dokud se p\u00edst neza\u010dne pohybovat. Po\u010d\u00e1te\u010dn\u00ed pohyb je poznat podle vyt\u00e9k\u00e1n\u00ed vody z jehly, co\u017e ukazuje s\u00edlu pot\u0159ebnou k p\u0159ekon\u00e1n\u00ed t\u0159en\u00ed.<\/li>\n\n\n\n<li><strong>Nucen\u00e9 nahr\u00e1v\u00e1n\u00ed<\/strong>: Zaznamen\u00e1v\u00e1 se maxim\u00e1ln\u00ed s\u00edla pot\u0159ebn\u00e1 k udr\u017een\u00ed pohybu p\u00edstu, co\u017e poskytuje z\u00e1sadn\u00ed \u00fadaje pro zaji\u0161t\u011bn\u00ed kvality a ov\u011b\u0159en\u00ed shody.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">V\u00fdhody pou\u017e\u00edv\u00e1n\u00ed testeru injek\u010dn\u00edch st\u0159\u00edka\u010dek MST-01<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Na str\u00e1nk\u00e1ch&nbsp;<strong>MST-01 Tester l\u00e9ka\u0159sk\u00fdch st\u0159\u00edka\u010dek<\/strong>&nbsp;je speci\u00e1ln\u011b navr\u017eeno k automatizaci a zefektivn\u011bn\u00ed zkou\u0161ek odtrhov\u00e9 s\u00edly a kluzn\u00e9 s\u00edly. Toto modern\u00ed zku\u0161ebn\u00ed za\u0159\u00edzen\u00ed nab\u00edz\u00ed:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>P\u0159esn\u00e9 testov\u00e1n\u00ed<\/strong>: D\u00edky p\u0159esnosti 0,51 TP4T pln\u00e9ho rozsahu (F.S.) poskytuje p\u0159\u00edstroj MST-01 p\u0159esn\u00e9 a spolehliv\u00e9 v\u00fdsledky.<\/li>\n\n\n\n<li><strong>V\u00edce testovac\u00edch program\u016f<\/strong>: Je schopen prov\u00e1d\u011bt celou \u0159adu zkou\u0161ek, v\u010detn\u011b zkou\u0161ek odtrhov\u00e9 s\u00edly, kluzn\u00e9 s\u00edly a odporu p\u00edstu, kter\u00e9 jsou v\u0161echny nezbytn\u00e9 pro kontrolu kvality injek\u010dn\u00edch st\u0159\u00edka\u010dek.<\/li>\n\n\n\n<li><strong>Snadn\u00e9 pou\u017e\u00edv\u00e1n\u00ed<\/strong>: 7palcov\u00fd dotykov\u00fd displej HMI zjednodu\u0161uje ovl\u00e1d\u00e1n\u00ed, zat\u00edmco \u0159\u00edzen\u00ed pomoc\u00ed PLC zaji\u0161\u0165uje st\u00e1l\u00e9 testovac\u00ed podm\u00ednky.<\/li>\n\n\n\n<li><strong>\u0160irok\u00e1 \u0161k\u00e1la test\u016f<\/strong>: P\u0159\u00edstroj MST-01 je natolik univerz\u00e1ln\u00ed, \u017ee umo\u017e\u0148uje testovat r\u016fzn\u00e9 typy injek\u010dn\u00edch st\u0159\u00edka\u010dek, v\u010detn\u011b t\u011bch, kter\u00e9 se pou\u017e\u00edvaj\u00ed k injekc\u00edm a o\u010dkov\u00e1n\u00ed, v souladu s normami jako ISO 8537, ISO 11608-5 a USP 382.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Hlavn\u00ed normy ISO pro zkou\u0161en\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>ISO 8537<\/strong>: Tato norma stanovuje zku\u0161ebn\u00ed metody pro p\u0159edpln\u011bn\u00e9 injek\u010dn\u00ed st\u0159\u00edka\u010dky, v\u010detn\u011b zkou\u0161ek na odtrhovou s\u00edlu a kluznou s\u00edlu.<\/li>\n\n\n\n<li><strong>USP 382<\/strong>: Tato norma stanovuje po\u017eadavky na vlastnosti jednor\u00e1zov\u00fdch injek\u010dn\u00edch st\u0159\u00edka\u010dek, v\u010detn\u011b m\u011b\u0159en\u00ed s\u00edly pot\u0159ebn\u00e9 k pohybu p\u00edstu.<\/li>\n\n\n\n<li><strong>ISO 7886-1<\/strong>: Tato norma stanov\u00ed obecn\u00e9 pokyny pro steriln\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky pou\u017e\u00edvan\u00e9 v l\u00e9ka\u0159stv\u00ed, v\u010detn\u011b zku\u0161ebn\u00edch metod pro stanoven\u00ed s\u00edly pot\u0159ebn\u00e9 k uvoln\u011bn\u00ed.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Dodr\u017eov\u00e1n\u00edm t\u011bchto mezin\u00e1rodn\u011b uzn\u00e1van\u00fdch norem mohou v\u00fdrobci zajistit, \u017ee jejich injek\u010dn\u00ed st\u0159\u00edka\u010dky budou funk\u010dn\u00ed a z\u00e1rove\u0148 bezpe\u010dn\u00e9 pro l\u00e9ka\u0159sk\u00e9 pou\u017eit\u00ed.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<h3 class=\"wp-block-heading\">\u010casto kladen\u00e9 ot\u00e1zky (FAQ)<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>K \u010demu slou\u017e\u00ed zkou\u0161ka odtrhov\u00e9 s\u00edly u injek\u010dn\u00edch st\u0159\u00edka\u010dek?<\/strong><br>Zkou\u0161ka odtrhov\u00e9 s\u00edly m\u011b\u0159\u00ed s\u00edlu pot\u0159ebnou k zah\u00e1jen\u00ed pohybu p\u00edstu v injek\u010dn\u00ed st\u0159\u00edka\u010dce, \u010d\u00edm\u017e se zaji\u0161\u0165uje, \u017ee injek\u010dn\u00ed st\u0159\u00edka\u010dky funguj\u00ed spr\u00e1vn\u011b a jsou bezpe\u010dn\u00e9 pro pou\u017eit\u00ed v l\u00e9ka\u0159sk\u00fdch aplikac\u00edch.<\/li>\n\n\n\n<li><strong>Pro\u010d je p\u0159i testov\u00e1n\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek d\u016fle\u017eit\u00e1 kluzn\u00e1 s\u00edla?<\/strong><br>S\u00edla kluzu ud\u00e1v\u00e1 odpor proti pohybu p\u00edstu v okam\u017eiku, kdy se p\u00edst za\u010dne pohybovat. Zaji\u0161\u0165uje plynul\u00fd a rovnom\u011brn\u00fd tok tekutiny p\u0159i prov\u00e1d\u011bn\u00ed l\u00e9ka\u0159sk\u00fdch injekc\u00ed, \u010d\u00edm\u017e usnad\u0148uje pr\u00e1ci zdravotnick\u00e9mu person\u00e1lu.<\/li>\n\n\n\n<li><strong>Jak se prov\u00e1d\u00ed zkou\u0161ka s\u00edly pot\u0159ebn\u00e9 k uvoln\u011bn\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky?<\/strong><br>St\u0159\u00edka\u010dka se napln\u00ed vodou, upne se do zku\u0161ebn\u00edho stroje a na p\u00edst se p\u016fsob\u00ed svislou silou, dokud se neza\u010dne pohybovat. S\u00edla pot\u0159ebn\u00e1 k zah\u00e1jen\u00ed tohoto pohybu se zaznamen\u00e1 pro \u00fa\u010dely zaji\u0161t\u011bn\u00ed kvality.<\/li>\n\n\n\n<li><strong>Jak\u00e9 normy upravuj\u00ed testov\u00e1n\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek?<\/strong><br>Normy ISO 8537, USP 382 a ISO 7886-1 jsou kl\u00ed\u010dov\u00e9 normy, kter\u00e9 upravuj\u00ed zkou\u0161en\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek, v\u010detn\u011b zkou\u0161ek s\u00edly pot\u0159ebn\u00e9 k uvoln\u011bn\u00ed a s\u00edly pot\u0159ebn\u00e9 k posunu.<\/li>\n\n\n\n<li><strong>Jak\u00e9 jsou v\u00fdhody pou\u017e\u00edv\u00e1n\u00ed testeru injek\u010dn\u00edch st\u0159\u00edka\u010dek MST-01?<\/strong><br>P\u0159\u00edstroj MST-01 umo\u017e\u0148uje p\u0159esn\u00e9, automatizovan\u00e9 testov\u00e1n\u00ed odtrhov\u00e9 a kluzn\u00e9 s\u00edly, \u010d\u00edm\u017e zaji\u0161\u0165uje, \u017ee injek\u010dn\u00ed st\u0159\u00edka\u010dky spl\u0148uj\u00ed normy kvality. Je u\u017eivatelsky p\u0159\u00edv\u011btiv\u00fd, univerz\u00e1ln\u00ed a umo\u017e\u0148uje prov\u00e1d\u011bt \u0159adu zkou\u0161ek souvisej\u00edc\u00edch se silou v souladu s normami ISO a USP.<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>P\u0159edchoz\u00ed<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>The syringe break loose force test plays a crucial role in evaluating the performance and quality of syringes used in medical and pharmaceutical applications. This test determines the force required to initiate piston movement within a syringe, ensuring that syringes meet stringent usability and safety standards. In this article, we will delve into the specifics [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1060","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/posts\/1060","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/comments?post=1060"}],"version-history":[{"count":0,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/posts\/1060\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/media?parent=1060"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/categories?post=1060"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.materialstests.com\/cs\/wp-json\/wp\/v2\/tags?post=1060"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}